{"product_id":"bently-nevada-200151-60-03-00-accelerometer-interface-standard-cable","title":"200151-60-03-00 Bently Nevada Accelerometer Cable Armor-Protected","description":"\u003ch3\u003eGlobal PLC Spare HUB's Insight\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #d32f2f;\"\u003e200151-60-03-00\u003c\/span\u003e\u003c\/strong\u003e is the industry standard for secure, interference-free vibration data transmission. Our engineering team at Global PLC Spare HUB identifies this cable's 85% coverage braided shield as the primary defense against electromagnetic noise in heavy industrial zones. The integrated armor and IP67-rated molded connectors provide a robust pathway for high-frequency signal transit, ensuring that your diagnostic software receives clean data even in harsh wash-down or moisture-prone operating environments.\u003c\/p\u003e\n\n\u003ch3\u003eConfiguration Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003e\u003cspan style=\"color: #d32f2f;\"\u003e200151\u003c\/span\u003e\u003c\/strong\u003e: Base Series (Accelerometer Interface Standard Cable)\n        \u003cul\u003e\n            \u003cli\u003eCable Length: -60 (6.0 meters)\u003c\/li\u003e\n            \u003cli\u003eArmor Option: 03 (Blue cable with armor)\u003c\/li\u003e\n            \u003cli\u003eCoupling Nut: 00 (Standard nickel-plated coupling nut)\u003c\/li\u003e\n        \u003c\/ul\u003e\n    \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003eCable Architecture: 4-conductor, 22 AWG shielded design.\u003c\/li\u003e\n    \u003cli\u003eShielding: Braided shield plus drain wire (min. 85% coverage).\u003c\/li\u003e\n    \u003cli\u003eProtection Rating: IP67 (when mated to transducers).\u003c\/li\u003e\n    \u003cli\u003eFlexibility: 63.5 mm (2.5 in) minimum bend radius.\u003c\/li\u003e\n    \u003cli\u003eThermal Thresholds: -20 °C to +100 °C (-4 °F to +212 °F) operational range.\u003c\/li\u003e\n    \u003cli\u003eMaterial: PVC outer jacket with nickel-plated coupling nuts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eIndustrial Applications \u0026amp; Diagnostics\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003eRecommended Equipment: Industrial accelerometers, seismic sensors, and velocity transducers.\u003c\/li\u003e\n    \u003cli\u003eUse Cases: Vibration monitoring in high-moisture areas, outdoor turbine installations, and motor-bearing health diagnostics.\u003c\/li\u003e\n    \u003cli\u003eDiagnostic Capability: Minimizes signal loss and EMI-induced \"noise,\" preventing false vibration alarms and ensuring precision frequency analysis.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eGlobal PLC Spare HUB Support\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003eWarranty: 12-month manufacturer quality assurance coverage.\u003c\/li\u003e\n    \u003cli\u003eShipping: Global express delivery via FedEx, UPS, or DHL with rapid 24-48 hour dispatch.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eProfessional FAQ\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWhat is the purpose of the DC4 compound in the connectors?\u003c\/strong\u003e\u003cbr\u003e\n    The DC4 insulating compound provides a critical moisture barrier, protecting the electrical connection during rapid thermal shock events.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCan I route this cable around tight machinery corners?\u003c\/strong\u003e\u003cbr\u003e\n    The cable has a minimum bend radius of 63.5 mm; exceeding this (tighter bends) can stress the internal conductors and degrade signal performance.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eIs the armor option strictly necessary for all applications?\u003c\/strong\u003e\u003cbr\u003e\n    While the blue armor provides significant physical abrasion resistance, it is highly recommended in environments where cables are exposed to foot traffic or sharp debris.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eHow should I verify a proper IP67 seal during installation?\u003c\/strong\u003e\u003cbr\u003e\n    Hand-tighten the nickel-plated coupling nut until it is firm; the molded connector design ensures a splash-proof seal without the need for excessive over-torquing.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWhy does the temperature rating limit flexing below -20 °C?\u003c\/strong\u003e\u003cbr\u003e\n    At temperatures below -20 °C, the PVC jacket becomes brittle; mechanical flexing at these temperatures risks cracking the jacket and compromising the shield integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSelection Guidance\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003eCalculate your exact path length, including cable \"slack\" for sensor maintenance, before selecting the -60 (6-meter) length.\u003c\/li\u003e\n    \u003cli\u003eIf your environment involves exposure to caustic chemicals, ensure the PVC jacket material is compatible with the specific agents present in your facility.\u003c\/li\u003e\n    \u003cli\u003eAlways keep the DC4 compound clean; contaminants within the compound can cause intermittent signal issues between the transducer and the monitor.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013929328822,"sku":"200151-60-03-00","price":132.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/200151-5.jpg?v=1782889753","url":"https:\/\/www.plcsparehub.com\/products\/bently-nevada-200151-60-03-00-accelerometer-interface-standard-cable","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}