{"product_id":"bently-nevada-138131-006-10base-t-rj45-industrial-cable","title":"Bently Nevada 138131-006 10BASE-T RJ45 Industrial Cable","description":"\u003ch3 style=\"font-size: 1.5em; font-weight: bold; margin-bottom: 10px;\"\u003eProduct Introduction\u003c\/h3\u003e\n\u003cp\u003eEngineered for robust industrial networking, the \u003cstrong\u003eBently Nevada\u003c\/strong\u003e \u003cstrong\u003e138131-006\u003c\/strong\u003e \u003cstrong\u003eStandard 10BASE-T Shielded Category 5 Cable\u003c\/strong\u003e delivers reliable data transmission in demanding plant environments. Designed to interface seamlessly with monitoring racks and machinery protection systems, this cable minimizes electromagnetic interference to maintain signal integrity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e: In high-vibration turbine monitoring setups, using certified shielded cabling prevents intermittent communication drops that standard commercial patch cables often experience due to ground loops.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size: 1.5em; font-weight: bold; margin-top: 20px; margin-bottom: 10px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px;\"\u003e\n  \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n    \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n    \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eSpecification Details\u003c\/th\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n    \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eBently Nevada\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n    \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003e138131-006\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n    \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eStandard 10BASE-T Shielded Category 5 Series\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n    \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px;\"\u003eDual RJ-45 modular plugs with integrated strain relief\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n    \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px;\"\u003eShielded Category 5 (10BASE-T compatible)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n    \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eLength Options\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px;\"\u003eStandard 6 ft (1.8 meters); Custom lengths up to 320 ft available\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n    \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eOrdering Increments\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px;\"\u003e30 ft to 100 ft ordered in 5 ft increments; 100 ft to 320 ft ordered in 10 ft increments\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n    \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px;\"\u003e-20°C to +75°C operational tolerance\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n    \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eEnvironmental Tolerance\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px;\"\u003eResistant to industrial dust, moisture, and moderate oil exposure\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n    \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eInterference Resistance\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px;\"\u003eFoil shielding with drain wire for high EMI\/RFI suppression\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n    \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding: 8px;\"\u003eComprehensive 12-month industrial replacement coverage\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"font-size: 1.5em; font-weight: bold; margin-top: 20px; margin-bottom: 10px;\"\u003eInstallation \u0026amp; Commissioning Guide\u003c\/h3\u003e\n\u003cul style=\"margin-left: 20px; margin-bottom: 20px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePre-Installation Inspection\u003c\/strong\u003e: Verify that the \u003cstrong\u003e138131-006\u003c\/strong\u003e cable jacket shows no abrasions and that both \u003cstrong\u003eRJ-45\u003c\/strong\u003e connectors click securely into port latches.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRouting Best Practices\u003c\/strong\u003e: Keep the cable physically separated from high-voltage motor power lines by at least 30 cm to prevent induced noise on the \u003cstrong\u003e10BASE-T\u003c\/strong\u003e physical layer.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding Compliance\u003c\/strong\u003e: Ensure the equipment rack chassis maintains proper earth grounding so the built-in cable shield effectively shunts high-frequency noise.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePost-Installation Testing\u003c\/strong\u003e: Perform a link-status verification using diagnostic LEDs on the connected monitoring node to confirm zero packet loss.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"font-size: 1.5em; font-weight: bold; margin-top: 20px; margin-bottom: 10px;\"\u003eMaintenance \u0026amp; Diagnostic Capabilities\u003c\/h3\u003e\n\u003cul style=\"margin-left: 20px; margin-bottom: 20px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoutine Checkpoints\u003c\/strong\u003e: Annually inspect connector locking tabs and verify that cable bend radii remain above the 4x outer diameter threshold.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFault Isolation\u003c\/strong\u003e: If link drops occur, check for continuity across the foil shield and ensure oxidation has not formed on the \u003cstrong\u003eRJ-45\u003c\/strong\u003e gold-plated pins.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDiagnostic Insight\u003c\/strong\u003e: Modern rack diagnostic software will report CRC errors if improper shielding allows plant-floor inverter harmonics to corrupt data packets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"font-size: 1.5em; font-weight: bold; margin-top: 20px; margin-bottom: 10px;\"\u003eCompatibility \u0026amp; Integration\u003c\/h3\u003e\n\u003cul style=\"margin-left: 20px; margin-bottom: 20px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e: Fully compatible with \u003cstrong\u003eBently Nevada\u003c\/strong\u003e rack-based monitoring hardware and standard industrial switches supporting \u003cstrong\u003e10BASE-T\u003c\/strong\u003e protocols.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInterface Standards\u003c\/strong\u003e: Adheres to TIA\/EIA-568 standards for structured cabling in heavy industrial control rooms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"font-size: 1.5em; font-weight: bold; margin-top: 20px; margin-bottom: 10px;\"\u003ePackage Contents \u0026amp; Logistics\u003c\/h3\u003e\n\u003cul style=\"margin-left: 20px; margin-bottom: 20px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBox Contents\u003c\/strong\u003e: One \u003cstrong\u003e138131-006\u003c\/strong\u003e \u003cstrong\u003eBently Nevada\u003c\/strong\u003e Shielded Cat5 Cable (6 ft standard length unless customized).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFulfillment Speed\u003c\/strong\u003e: Dispatched within 24-48 hours of order confirmation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCarrier Options\u003c\/strong\u003e: Express delivery available via FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"font-size: 1.5em; font-weight: bold; margin-top: 20px; margin-bottom: 10px;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I order a custom length outside of the standard 6 ft offering?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. Custom lengths up to 320 ft can be ordered through \u003cstrong\u003eBently Nevada\u003c\/strong\u003e Custom Products, adhering to 5 ft increments between 30-100 ft and 10 ft increments between 100-320 ft.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What field issue commonly causes intermittent link failure with this cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Field experience shows that failing to properly ground the equipment rack allows ground potential differences to overload the shield, causing packet corruption. Always verify panel earth continuity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this cable suitable for outdoor direct burial installations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The \u003cstrong\u003e138131-006\u003c\/strong\u003e is designed for indoor control room and rack-to-rack cabinet routing and lacks weather-resistant armor for direct outdoor exposure.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45353257238710,"sku":"138131-006","price":116.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330730-040-02-05.jpg?v=1786606880","url":"https:\/\/www.plcsparehub.com\/products\/bently-nevada-138131-006-10base-t-rj45-industrial-cable","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}