{"product_id":"atv930d15n4-altivar-process-schneider-industrial-inverter","title":"ATV930D15N4 Altivar Process Schneider Industrial Inverter","description":"\u003ch3\u003e\u003cstrong\u003eATV930D15N4 | Industrial Drive Engineering Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #1673b1;\"\u003e\u003cstrong\u003eATV930D15N4\u003c\/strong\u003e\u003c\/span\u003e belongs to the Schneider Electric Altivar Process ATV900 range. This wall-mounted variable speed drive controls compatible asynchronous and synchronous motors in industrial process applications.\u003c\/p\u003e\n\u003cp\u003eIts integrated braking chopper supports applications requiring controlled deceleration. Built-in Ethernet\/IP and Modbus communication simplify integration with compatible automation systems.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eEngineering Parameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct family\u003c\/td\u003e\n\u003ctd\u003eAltivar Process ATV900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eATV930D15N4\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003eVariable speed drive \/ industrial inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated motor power\u003c\/td\u003e\n\u003ctd\u003e15 kW normal duty; 11 kW heavy duty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage\u003c\/td\u003e\n\u003ctd\u003eThree-phase 380–480 V AC, −15% to +10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply frequency\u003c\/td\u003e\n\u003ctd\u003e50–60 Hz, ±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency\u003c\/td\u003e\n\u003ctd\u003e0.1–599 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous output current\u003c\/td\u003e\n\u003ctd\u003e31.7 A normal duty; 23.5 A heavy duty at 4 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking\u003c\/td\u003e\n\u003ctd\u003eIntegrated braking chopper; verify the external braking resistor requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure protection\u003c\/td\u003e\n\u003ctd\u003eIP21; UL Type 1 classification stated in the product specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling method\u003c\/td\u003e\n\u003ctd\u003eForced convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eWall mounting, vertical orientation ±10°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × H × D)\u003c\/td\u003e\n\u003ctd\u003e211 × 545.9 × 235 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproximate weight\u003c\/td\u003e\n\u003ctd\u003e13.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety function\u003c\/td\u003e\n\u003ctd\u003eSafe Torque Off (STO), SIL 3 specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003e01 | Select by Load, Not Motor Power Alone\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #1673b1;\"\u003e\u003cstrong\u003eATV930D15N4\u003c\/strong\u003e\u003c\/span\u003e supports different motor ratings according to the selected duty profile. Confirm the machine's torque demand, acceleration cycle, and overload duration before choosing the drive.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormal-duty applications:\u003c\/strong\u003e Supports motor ratings up to 15 kW, with a stated continuous output current of 31.7 A at 4 kHz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeavy-duty applications:\u003c\/strong\u003e Supports motor ratings up to 11 kW, with a stated continuous output current of 23.5 A at 4 kHz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-torque loads:\u003c\/strong\u003e Consider compatible pump and fan systems after checking the operating curve and required motor current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConstant-torque loads:\u003c\/strong\u003e Verify starting torque, low-speed operation, overload requirements, and the actual duty classification.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEngineering selection note:\u003c\/strong\u003e The correct rating depends on the application duty, motor nameplate current, ambient temperature, switching frequency, and required overload capability. Apply the manufacturer's derating rules when operating outside the standard conditions.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e02 | Motor and Machine Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThis drive supports compatible asynchronous motors and synchronous motor types, including permanent-magnet and synchronous-reluctance motors. The final selection must match the motor data and the control method required by the machine.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eEquipment or Application\u003c\/th\u003e\n\u003cth\u003eIntegration Considerations\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial pumps\u003c\/td\u003e\n\u003ctd\u003eEvaluate flow demand, pressure control, acceleration ramps, and process feedback.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVentilation and industrial fans\u003c\/td\u003e\n\u003ctd\u003eCheck variable-torque requirements, minimum operating speed, and airflow control.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConveyors and material handling\u003c\/td\u003e\n\u003ctd\u003eVerify starting torque, load inertia, stopping time, and braking requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess machinery\u003c\/td\u003e\n\u003ctd\u003eConfirm the required speed profile, control sequence, and automation interface.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible synchronous motor systems\u003c\/td\u003e\n\u003ctd\u003eCheck motor identification, supported control configuration, and commissioning requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMachines requiring controlled deceleration\u003c\/td\u003e\n\u003ctd\u003eAssess regenerative energy, braking duty, and external resistor sizing where applicable.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese examples describe potential applications, not universal plug-and-play compatibility. Confirm the machine's electrical, mechanical, and control requirements before installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e03 | Control Architecture and Communication\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ATV930D15N4 provides integrated communication and configurable I\/O for industrial control integration. Engineers should verify the selected protocol, PLC configuration, and required control signals before commissioning.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEtherNet\/IP:\u003c\/strong\u003e Supports communication with compatible industrial controllers and network devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModbus TCP:\u003c\/strong\u003e Provides Ethernet-based communication through the drive's control-block RJ45 interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModbus serial:\u003c\/strong\u003e Uses a two-wire RS-485 interface with RTU framing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog inputs:\u003c\/strong\u003e Three configurable voltage or current inputs support 0–10 V and 0\/4–20 mA signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital inputs:\u003c\/strong\u003e Eight programmable digital inputs support control functions; DI7 and DI8 can also accept pulse inputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog outputs:\u003c\/strong\u003e Two configurable outputs support 0–10 V or 0–20 mA signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay outputs:\u003c\/strong\u003e Three configurable relay outputs support fault and sequence signaling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpansion options:\u003c\/strong\u003e Compatible option modules can provide additional communication, I\/O, or encoder interfaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eConfirm the installed option card before specifying PROFINET, PROFIBUS DP, CANopen, EtherCAT, DeviceNet, or other optional networks. Do not assume every protocol is available in the standard configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e04 | Diagnostic Capabilities and Fault Isolation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe drive provides local LED indicators, communication-status LEDs, and multiple electrical and thermal protection functions. These features help maintenance teams narrow down faults before replacing components.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eObserved Symptom\u003c\/th\u003e\n\u003cth\u003eRecommended Checks\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive does not start\u003c\/td\u003e\n\u003ctd\u003eCheck supply status, active fault indications, run-command source, interlocks, and STO input states.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor fails to reach commanded speed\u003c\/td\u003e\n\u003ctd\u003eCompare the reference signal, configured frequency limits, load demand, current limits, and active operating mode.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvercurrent or output fault\u003c\/td\u003e\n\u003ctd\u003eInspect motor cables, insulation condition, motor connections, acceleration time, mechanical binding, and load inertia.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC bus overvoltage during stopping\u003c\/td\u003e\n\u003ctd\u003eReview deceleration time, load inertia, braking frequency, and the suitability of the braking resistor arrangement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive overheating\u003c\/td\u003e\n\u003ctd\u003eCheck cooling airflow, cabinet ventilation, ambient temperature, switching frequency, dust accumulation, and load current.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePLC communication failure\u003c\/td\u003e\n\u003ctd\u003eVerify the protocol, IP or serial settings, cable connections, network status, and installed communication option.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnexpected speed feedback or command behavior\u003c\/td\u003e\n\u003ctd\u003eCheck analog scaling, signal type, common reference wiring, parameter assignments, and the controller's command source.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eField troubleshooting practice:\u003c\/strong\u003e Record the displayed fault code, operating state, motor current, speed reference, and event timing before resetting the drive. A recurring fault may indicate a load, wiring, configuration, or supply problem rather than a failed inverter.\u003c\/p\u003e\n\u003cp\u003eThe drive's protection functions include thermal protection, output short-circuit protection, motor phase-loss detection, DC-bus and supply overvoltage monitoring, undervoltage monitoring, and overspeed protection. Available functions and trip behavior depend on the configured system and operating conditions.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e05 | Installation and Commissioning Checkpoints\u003c\/strong\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify the supply:\u003c\/strong\u003e Confirm three-phase 380–480 V compatibility and check the upstream protective device against the manufacturer's instructions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm motor ratings:\u003c\/strong\u003e Compare motor voltage, current, power, frequency, and control requirements with the selected duty profile.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect the installation:\u003c\/strong\u003e Mount the drive vertically within the specified tolerance and provide suitable airflow for forced-convection cooling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck cable sizing:\u003c\/strong\u003e Follow the applicable wiring diagram and local electrical regulations for line, motor, DC-bus, and control conductors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfigure control signals:\u003c\/strong\u003e Validate analog scaling, digital input assignments, command channels, speed limits, and communication parameters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValidate braking:\u003c\/strong\u003e Confirm whether the machine requires a braking resistor and calculate its resistance, power, and duty requirements using approved documentation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest safely:\u003c\/strong\u003e Verify rotation direction, acceleration, deceleration, stopping behavior, interlocks, and fault responses under controlled conditions.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe IP21 enclosure does not provide protection against every industrial dust or moisture exposure. Use an appropriate cabinet or environmental solution when the installation conditions require additional protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety reminder:\u003c\/strong\u003e STO is a safety function, not electrical isolation. Disconnect and verify all hazardous energy sources before maintenance, and follow the machine's complete safety design.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e06 | Global PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWhen replacing an installed drive, engineers should compare more than the model number and rated kilowatts. Differences in duty rating, output current, braking arrangement, communication options, and control wiring can affect commissioning and machine availability.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRecord the existing drive model and all installed option-card references.\u003c\/li\u003e\n\u003cli\u003eCompare the motor nameplate current against the correct normal-duty or heavy-duty rating.\u003c\/li\u003e\n\u003cli\u003eDocument PLC communication settings, control references, and safety-circuit connections before replacement.\u003c\/li\u003e\n\u003cli\u003eCheck braking requirements where the machine has high inertia or frequent deceleration cycles.\u003c\/li\u003e\n\u003cli\u003eConfirm cabinet dimensions, cooling clearance, wiring terminals, and environmental conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eGlobal PLC Spare HUB recommends confirming the complete application details before ordering. Providing the motor nameplate, existing drive label, and control-system requirements helps reduce selection errors and commissioning delays.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e07 | Supply, Shipping and Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12-month warranty, subject to the seller's applicable warranty terms and conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping options:\u003c\/strong\u003e FedEx, UPS, or DHL, subject to destination, service availability, and shipment arrangements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder verification:\u003c\/strong\u003e Confirm the exact model, quantity, delivery destination, and any required accessories before dispatch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTechnical assistance:\u003c\/strong\u003e Contact our team with the application details if you need help checking motor or communication compatibility.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eContact Global PLC Spare HUB for current pricing, availability, delivery estimates, and model verification before placing your order.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e08 | Frequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1. How can I decide whether this drive should operate in normal-duty or heavy-duty mode?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Start with the motor nameplate current and the machine's torque profile. The stated ratings are 15 kW normal duty and 11 kW heavy duty. Confirm overload duration, acceleration requirements, and the manufacturer's duty-selection rules before finalizing the configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2. What information should I send when requesting a replacement for an existing ATV930 drive?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Provide the complete model number, motor nameplate, supply voltage, load type, communication protocol, and installed option cards. Photos of the existing wiring and parameter settings can also help identify integration differences before purchase.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3. Does the integrated braking chopper mean I can connect any braking resistor directly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. The integrated chopper does not establish compatibility with every resistor. Check the manufacturer's approved resistance range, power rating, thermal duty, wiring requirements, and braking-cycle limits before installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4. If the drive communicates with the PLC but the motor will not run, what should I check first?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Check the active command source, run permissives, fault status, speed reference, and STO input states. Then verify the selected control mode and relevant digital input assignments. Follow the drive's diagnostic instructions before changing parameters or replacing hardware.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5. Can I use the STO SIL 3 specification as proof that my complete machine meets SIL 3?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. The drive's stated STO capability does not certify the complete machine safety function by itself. The safety assessment must consider the full architecture, external devices, wiring, diagnostics, installation, and applicable standards.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Selection and Quote Request\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNeed the Schneider Electric \u003cspan style=\"color: #1673b1;\"\u003e\u003cstrong\u003eATV930D15N4\u003c\/strong\u003e\u003c\/span\u003e for a drive replacement or new industrial installation? Send your required quantity, destination, motor rating, and application details to request a quotation and compatibility review.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/ATV930D15N4.png?v=1792131757\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":67651689349302,"sku":"ATV930D15N4","price":125.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/ATV930D15N4-1.jpg?v=1792131742","url":"https:\/\/www.plcsparehub.com\/products\/atv930d15n4-altivar-process-schneider-industrial-inverter","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}