{"product_id":"atom4t0-300-renishaw-high-speed-atom-40µm-encoder-readhead","title":"ATOM4T0-300 Renishaw High-Speed ATOM 40µm Encoder Readhead","description":"\u003ch3\u003e\u003cstrong\u003eProduct Identity | Renishaw ATOM Miniature Encoder\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong style=\"color: #e87516;\"\u003eRenishaw ATOM4T0-300\u003c\/strong\u003e is a miniature optical incremental encoder readhead. It belongs to the \u003cstrong style=\"color: #e87516;\"\u003eATOM™ 40 µm encoder family\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis configuration combines a compact optical sensing head with a 3 m cable. It uses a 40 µm scale pitch and supports external digital interpolation.\u003c\/p\u003e\n\u003cp\u003eThe readhead provides non-contact position measurement for precision motion systems. Its compact housing suits equipment with restricted installation space.\u003c\/p\u003e\n\u003cp\u003eThe integrated optical filtering system improves signal stability under normal industrial contamination conditions. Automatic gain control (AGC) and automatic offset control (AOC) support consistent signal conditioning.\u003c\/p\u003e\n\u003cp\u003eA built-in dual-colour LED provides installation feedback. Engineers can check optical alignment without using an oscilloscope during initial setup.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e01 | Configuration Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eUnderstanding each ordering code helps prevent incorrect interface and scale selection.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCode Section\u003c\/th\u003e\n\u003cth\u003eMeaning\u003c\/th\u003e\n\u003cth\u003eEngineering Description\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eATOM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eRenishaw miniature optical incremental encoder system.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScale Pitch\u003c\/td\u003e\n\u003ctd\u003e40 µm optical scale period.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReadhead Type\u003c\/td\u003e\n\u003ctd\u003eCabled version with an interboard connector.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScale Compatibility\u003c\/td\u003e\n\u003ctd\u003eRTLF40 and RKLF40 linear scales.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-300\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e3000 mm (3 m).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eComplete ordering reference:\u003c\/strong\u003e \u003cspan style=\"color: #e87516;\"\u003e\u003cstrong\u003eATOM4T0-300\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant selection note:\u003c\/strong\u003e The T configuration supports compatible Ti, Ri and ACi interfaces. It does not independently identify a top-exit mounting arrangement.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e02 | Technical Specification\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eTechnical Details\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eRenishaw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eATOM4T0-300\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eATOM™\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Category\u003c\/td\u003e\n\u003ctd\u003eMiniature Optical Incremental Encoder Readhead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Principle\u003c\/td\u003e\n\u003ctd\u003eNon-contact optical incremental measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale Pitch\u003c\/td\u003e\n\u003ctd\u003e40 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReadhead Configuration\u003c\/td\u003e\n\u003ctd\u003eT – Cabled, interboard connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale Compatibility Code\u003c\/td\u003e\n\u003ctd\u003e0 – RTLF40 \/ RKLF40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e1 Vpp analogue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterpolation\u003c\/td\u003e\n\u003ctd\u003eExternal interpolation interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailable Digital Resolution\u003c\/td\u003e\n\u003ctd\u003eDown to 1 nm with a compatible Ti interface configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Operating Speed\u003c\/td\u003e\n\u003ctd\u003e20 m\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReadhead Dimensions\u003c\/td\u003e\n\u003ctd\u003e8.35 × 12.7 × 20.5 mm (H × W × L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e−20 °C to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP40, cabled readhead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRide Height Tolerance\u003c\/td\u003e\n\u003ctd\u003e0.110 mm after calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Conditioning\u003c\/td\u003e\n\u003ctd\u003eAutomatic gain and offset control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Indicator\u003c\/td\u003e\n\u003ctd\u003eIntegrated dual-colour LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eResolution clarification:\u003c\/strong\u003e The 1 nm figure refers to the available digital interpolation resolution. The Ti interface determines the configured output resolution.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e03 | Optical and Signal Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ATOM system separates optical detection from electronic interpolation. This arrangement allows engineers to select an interface suited to the controller.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical sensing:\u003c\/strong\u003e Detects incremental graduations on the compatible scale.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal generation:\u003c\/strong\u003e Produces 1 Vpp analogue signals directly from the readhead.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal conditioning:\u003c\/strong\u003e AGC and AOC help maintain stable signal characteristics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital interpolation:\u003c\/strong\u003e External electronics convert analogue signals into digital position information.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePosition feedback:\u003c\/strong\u003e The receiving controller processes incremental position and reference information.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe integrated optical filtering system helps maintain signal quality. It also improves tolerance to common industrial surface contamination.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e04 | Compatible Interfaces and Scales\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eInterface selection must match the readhead connection and controller requirements.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003eCompatibility \/ Function\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTi Interface\u003c\/td\u003e\n\u003ctd\u003eHigh-performance digital interpolation interface.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRi Interface\u003c\/td\u003e\n\u003ctd\u003eExternal interpolation interface for compatible ATOM systems.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eACi Interface\u003c\/td\u003e\n\u003ctd\u003eCompact interface option for compatible system configurations.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustomer PCB\u003c\/td\u003e\n\u003ctd\u003eCustom electronics with suitable signal processing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTLF40\u003c\/td\u003e\n\u003ctd\u003e40 µm stainless-steel linear tape scale.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRKLF40\u003c\/td\u003e\n\u003ctd\u003e40 µm narrow stainless-steel linear tape scale.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional scale configurations:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRCLC40:\u003c\/strong\u003e 40 µm glass linear scale. Requires scale compatibility code 1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRCDM40:\u003c\/strong\u003e 40 µm glass rotary disc. Requires a suitable rotary compatibility configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering caution:\u003c\/strong\u003e ATOM4T0-300 specifically identifies scale compatibility code 0. Do not assume every ATOM-compatible scale works with this exact configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e05 | Installation and Commissioning\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eAccurate mechanical positioning is essential for reliable optical signal generation.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eConfirm the scale pitch matches the 40 µm readhead configuration.\u003c\/li\u003e\n\u003cli\u003eCheck the scale surface for scratches, oil and foreign particles.\u003c\/li\u003e\n\u003cli\u003eInstall the readhead bracket on a stable machine reference surface.\u003c\/li\u003e\n\u003cli\u003ePosition the readhead within the specified ride height tolerance.\u003c\/li\u003e\n\u003cli\u003eCheck mounting alignment using the integrated LED indicator.\u003c\/li\u003e\n\u003cli\u003eConnect the readhead cable to the compatible interpolation interface.\u003c\/li\u003e\n\u003cli\u003eVerify the interface power supply and electrical connections.\u003c\/li\u003e\n\u003cli\u003eMonitor analogue signal quality during controlled axis movement.\u003c\/li\u003e\n\u003cli\u003eConfigure the required digital resolution in the interpolation interface.\u003c\/li\u003e\n\u003cli\u003eVerify reference mark detection and position counting.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eDo not adjust the readhead solely by visual inspection. Follow the installation drawing and applicable alignment tolerances.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e06 | Maintenance and Diagnostic Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED indication:\u003c\/strong\u003e Helps engineers identify optical alignment conditions during installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic gain control:\u003c\/strong\u003e Compensates for signal amplitude variations within its operating range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic offset control:\u003c\/strong\u003e Helps maintain balanced analogue signal characteristics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical filtering:\u003c\/strong\u003e Reduces sensitivity to common contamination encountered in factory environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal diagnostics:\u003c\/strong\u003e Compatible system configurations support Renishaw diagnostic tools.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eInspect the optical window and scale periodically. Remove contamination using approved cleaning materials.\u003c\/p\u003e\n\u003cp\u003eCheck cable routing for excessive bending, abrasion and connector stress. Recheck signal quality after mechanical maintenance.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e07 | Industrial Application\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe compact housing and high-speed measurement capability support precision motion applications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSemiconductor manufacturing and wafer positioning.\u003c\/li\u003e\n\u003cli\u003ePrecision linear stages and positioning platforms.\u003c\/li\u003e\n\u003cli\u003eElectronics assembly and automated inspection.\u003c\/li\u003e\n\u003cli\u003eCoordinate measuring and dimensional inspection equipment.\u003c\/li\u003e\n\u003cli\u003eHigh-speed automation and motion control systems.\u003c\/li\u003e\n\u003cli\u003ePrecision rotary positioning with compatible glass discs.\u003c\/li\u003e\n\u003cli\u003eCompact machine tools and laboratory instrumentation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e08 | Environmental and Mechanical Considerations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe open optical design requires suitable environmental protection. The readhead carries an IP40 rating in its cabled configuration.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDust:\u003c\/strong\u003e Keep the optical window and scale clean.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiquids:\u003c\/strong\u003e Do not expose the readhead to direct liquid ingress.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature:\u003c\/strong\u003e Maintain operation between 0 °C and +60 °C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration:\u003c\/strong\u003e Use a rigid mounting bracket to reduce relative movement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical interference:\u003c\/strong\u003e Follow Renishaw cable routing and grounding recommendations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical clearance:\u003c\/strong\u003e Check cable movement throughout the complete machine travel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e09 | Quality Assurance and Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct condition:\u003c\/strong\u003e Supplied as a new product in factory packing, subject to order confirmation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-delivery inspection:\u003c\/strong\u003e Product identification and external condition checks before shipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty period:\u003c\/strong\u003e 12 months from the agreed warranty commencement date.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuality support:\u003c\/strong\u003e Contact our team if a verified product quality issue occurs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTechnical assistance:\u003c\/strong\u003e Support with model identification and interface compatibility checks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty terms:\u003c\/strong\u003e The 12-month warranty covers verified product quality defects under normal operating conditions. Damage from incorrect installation, electrical misuse or external mechanical causes is excluded.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e10 | Packing and International Shipping\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWe arrange protective packing for industrial electronic components. The delivery scope follows the confirmed purchase order.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Renishaw ATOM4T0-300 encoder readhead.\u003c\/li\u003e\n\u003cli\u003eIntegrated 3 m cable, as specified by the model.\u003c\/li\u003e\n\u003cli\u003eApplicable product identification and documentation, subject to supply scope.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eShipping methods:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFedEx:\u003c\/strong\u003e International express delivery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPS:\u003c\/strong\u003e International parcel transportation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDHL:\u003c\/strong\u003e Express shipping for overseas orders.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eShipping options depend on destination, package dimensions and carrier service availability. Please contact us for a delivery quotation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e11 | Engineering FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Why should engineers select a 40 µm configuration instead of a 20 µm version?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe choice depends on the existing scale and required motion performance. A 40 µm system supports speeds up to 20 m\/s. Engineers should also evaluate interpolation resolution and machine accuracy requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What happens if the readhead signal remains unstable despite correct mechanical alignment?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the analogue signal amplitude and offset first. Inspect the cable connector and interface supply. Electrical interference or an incompatible interface can also cause unstable feedback.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can the ATOM4T0-300 replace an existing encoder from another manufacturer?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNot as a direct plug-and-play replacement. Compare scale pitch, analogue signal requirements, reference mark arrangement and controller input specifications. Mechanical mounting dimensions also require verification.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: How should buyers choose between Ti, Ri and ACi interfaces?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStart with the controller architecture and required output resolution. Ti suits high-performance digital interpolation requirements. Ri and ACi provide alternative interface arrangements. Check the specific interface datasheet before selecting the complete system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What should purchasing engineers confirm before ordering ATOM4T0-300?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConfirm the complete part number and 3 m cable requirement. Verify RTLF40 or RKLF40 scale compatibility. Check the existing interpolation interface and required mounting accessories. Request confirmation if the application uses RCLC or RCDM scales.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Renishaw","offers":[{"title":"Default Title","offer_id":68155293106358,"sku":"ATOM4T0-300","price":118.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/ATOM4TO-300-1.jpg?v=1795577114","url":"https:\/\/www.plcsparehub.com\/products\/atom4t0-300-renishaw-high-speed-atom-40%c2%b5m-encoder-readhead","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}