{"product_id":"anb10d-425-cu2n-yokogawa-anb10d-esb-bus-node-unit","title":"ANB10D-425\/CU2N Yokogawa ANB10D ESB Bus Node Unit","description":"\u003ch3\u003e\u003cb\u003eYokogawa \u003cspan style=\"color: #1673b8;\"\u003eANB10D-425\/CU2N\u003c\/span\u003e Dual-Redundant ESB Bus Node Unit\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cb\u003e01 | Hardware Identity and System Role\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cb\u003e\u003cspan style=\"color: #1673b8;\"\u003eYokogawa ANB10D-425\/CU2N\u003c\/span\u003e\u003c\/b\u003e is an ESB bus node unit for Yokogawa distributed control system installations. The ANB10D supports a dual-redundant ESB bus architecture. Its rack-mounted assembly provides an interface for connecting compatible I\/O modules to the control system. This ordering configuration includes a dual-redundant power supply, a 220–240 V AC supply option, and an ESB bus connector unit. The specified assembly weighs approximately 10 kg, including eight I\/O modules.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e02 | Configuration Anatomy: Decode ANB10D-425\/CU2N\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOrdering code\u003c\/th\u003e\n\u003cth\u003eConfiguration meaning\u003c\/th\u003e\n\u003cth\u003eEngineering relevance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eANB10D\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eNode unit for dual-redundant ESB bus\u003c\/td\u003e\n\u003ctd\u003eIdentifies the node hardware and bus architecture.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003e-4\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eDual-redundant power supply\u003c\/td\u003e\n\u003ctd\u003eDefines the selected power arrangement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003e2\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e220–240 V AC power supply\u003c\/td\u003e\n\u003ctd\u003eSpecifies the supply voltage for this order configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003e5\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic type without explosion protection\u003c\/td\u003e\n\u003ctd\u003eDefines the supplied environmental and protection option.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003e\/CU2N\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eESB bus connector unit\u003c\/td\u003e\n\u003ctd\u003eSpecifies the bus connection option.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e**Selected configuration:** ANB10D-425\/CU2N - Dual-redundant ESB bus node. - Dual-redundant power supply. - 220–240 V AC input. - Basic type without explosion protection. - ESB bus connector unit included in the model designation.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e03 | Technical Specifications\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eANB10D-425\/CU2N\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003eESB Bus Node Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus architecture\u003c\/td\u003e\n\u003ctd\u003eDual-redundant ESB bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply configuration\u003c\/td\u003e\n\u003ctd\u003eDual-redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelected supply voltage\u003c\/td\u003e\n\u003ctd\u003e220–240 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower consumption\u003c\/td\u003e\n\u003ctd\u003e230 VA, 120 W for the 220–240 V AC specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlternative family supply options\u003c\/td\u003e\n\u003ctd\u003e100–120 V AC, 50\/60 Hz; 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlternative family power consumption\u003c\/td\u003e\n\u003ctd\u003e100–120 V AC: 200 VA, 120 W; 24 V DC: 5.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded I\/O module quantity\u003c\/td\u003e\n\u003ctd\u003e8 modules, as stated in the supplied weight specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e19-inch rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack fastening\u003c\/td\u003e\n\u003ctd\u003eFour M5 screws with insulation bushes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproximate weight\u003c\/td\u003e\n\u003ctd\u003e10 kg, including eight I\/O modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExplosion protection\u003c\/td\u003e\n\u003ctd\u003eNot included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe alternative supply ratings describe the ANB10D family. They do not change the selected 220–240 V AC configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e04 | Power and Bus Architecture\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ANB10D serves as a node within a dual-redundant ESB bus arrangement. Engineers should confirm the compatible control unit, bus coupler, and system topology. Its dual-redundant power supply provides the specified redundant power configuration. The actual redundancy performance depends on the complete power distribution design. Before integrating the node, verify:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eControl system and ESB bus compatibility.\u003c\/li\u003e\n\u003cli\u003eApproved bus coupler and connector arrangement.\u003c\/li\u003e\n\u003cli\u003ePower supply wiring and redundancy design.\u003c\/li\u003e\n\u003cli\u003eInstalled I\/O module types and quantity.\u003c\/li\u003e\n\u003cli\u003eSystem configuration and node addressing requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe supplied information does not specify maximum node counts, bus cable lengths, or communication timing. Consult the applicable Yokogawa system documentation.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e05 | Rack Installation and Cabinet Planning\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cb\u003eANB10D-425\/CU2N\u003c\/b\u003e uses a 19-inch rack mounting arrangement. The supplied mounting specification identifies four M5 screws and insulation bushes. **Installation checklist**\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eConfirm the rack accepts the unit's mounting dimensions.\u003c\/li\u003e\n\u003cli\u003eCheck the available rack space and access for bus connections.\u003c\/li\u003e\n\u003cli\u003eVerify the 220–240 V AC supply and 50\/60 Hz frequency.\u003c\/li\u003e\n\u003cli\u003eInspect the insulation bushes and mounting hardware.\u003c\/li\u003e\n\u003cli\u003eSecure the assembly using the specified mounting arrangement.\u003c\/li\u003e\n\u003cli\u003eConnect the approved ESB bus interface.\u003c\/li\u003e\n\u003cli\u003eVerify I\/O module positions against the cabinet drawings.\u003c\/li\u003e\n\u003cli\u003eInspect wiring and grounding before commissioning.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe supplied product data does not provide exact rack clearance, terminal torque, or conductor size. Use the manufacturer's installation instructions for these details.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e06 | Compatible Equipment and Industrial Applications\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cb\u003e\u003cspan style=\"color: #1673b8;\"\u003eANB10D\u003c\/span\u003e\u003c\/b\u003e is designed for compatible Yokogawa ESB-based distributed control system installations.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eDistributed control systems:\u003c\/b\u003e Connect supported I\/O modules through the ESB bus architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eProcess automation:\u003c\/b\u003e Integrate field I\/O in engineered chemical, petrochemical, and manufacturing control systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePower and utility plants:\u003c\/b\u003e Support distributed process monitoring and control cabinets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eIndustrial plant expansion:\u003c\/b\u003e Add a node where the existing control system supports the required hardware and configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCabinet replacement projects:\u003c\/b\u003e Replace a matching node after verifying bus, power, and module compatibility.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eConfirm the exact controller family and I\/O module compatibility before purchase. The model description alone does not establish compatibility with every Yokogawa system.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e07 | Diagnostics and Commissioning Checks\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe supplied specifications do not identify onboard diagnostic indicators, detailed fault codes, or specific diagnostic software functions. Use the relevant Yokogawa system tools and manuals for module-level diagnostics. During commissioning, check the following areas:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003ePower supply:\u003c\/b\u003e Confirm the AC input and investigate power alarms through approved system diagnostics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eRedundant power:\u003c\/b\u003e Verify both supply paths according to the system's commissioning procedure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eESB communication:\u003c\/b\u003e Check connector seating, bus wiring, and controller recognition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eI\/O configuration:\u003c\/b\u003e Compare installed module positions with the system configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eNode identification:\u003c\/b\u003e Confirm addressing and configuration match the engineering records.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eField signal validation:\u003c\/b\u003e Test representative I\/O points through their connected modules.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e**Field example:** If the controller does not recognize a newly installed node, check the ESB connection and configuration first. Then verify the power supply and installed module arrangement. These checks help isolate installation issues before replacing hardware.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e08 | Compatibility and Procurement Review\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eConfirm these details before ordering a replacement or expansion unit:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComplete model code: ANB10D-425\/CU2N.\u003c\/li\u003e\n\u003cli\u003eExisting ESB bus architecture and compatible control unit.\u003c\/li\u003e\n\u003cli\u003eRequired connector unit and bus cable arrangement.\u003c\/li\u003e\n\u003cli\u003eInstalled I\/O module types and quantity.\u003c\/li\u003e\n\u003cli\u003e220–240 V AC supply availability.\u003c\/li\u003e\n\u003cli\u003eRack mounting provisions and cabinet space.\u003c\/li\u003e\n\u003cli\u003eEnvironmental requirements and explosion protection classification.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe selected basic configuration does not include explosion protection. Confirm site requirements before installation in any classified area.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e09 | Global PLC Spare HUB's Insight\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ANB10D should be selected as a complete node assembly rather than as an isolated rack component. Its suitability depends on the ESB architecture, power arrangement, and installed I\/O modules. For example, during a control cabinet expansion, an engineer may need to add another node while retaining the existing bus structure. The engineer should verify the controller's supported node capacity, cable arrangement, and configuration requirements. The stated 10 kg weight includes eight I\/O modules. Confirm the actual supplied assembly and module complement when planning handling, rack loading, or a replacement project.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e10 | Packaging, Warranty, and Shipping\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eProduct:\u003c\/b\u003e Yokogawa ANB10D-425\/CU2N ESB Bus Node Unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePackaging:\u003c\/b\u003e Protective packaging for industrial control equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eIncluded configuration:\u003c\/b\u003e Confirm the connector unit and eight-module assembly details with the supplier.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eWarranty:\u003c\/b\u003e 12-month warranty, subject to applicable sales terms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eShipping carriers:\u003c\/b\u003e FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eDispatch target:\u003c\/b\u003e 24–48 hours after order confirmation and stock verification.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003e11 | Frequently Asked Questions\u003c\/b\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cb\u003eDoes the ANB10D-425\/CU2N arrive with eight I\/O modules installed?\u003c\/b\u003e The supplied specification states an approximate weight of 10 kg, including eight I\/O modules. Confirm the exact module types and package contents before ordering.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e2. What is the difference between the ANB10D and a standard ESB node?\u003c\/b\u003e The ANB10D is specified for a dual-redundant ESB bus architecture. Check the system design and official documentation when comparing it with other node models.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e3. Can the existing cabinet support this assembly's weight?\u003c\/b\u003e The stated weight is approximately 10 kg, including eight I\/O modules. Check rack load capacity, mounting support, and handling requirements before installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e4. Does the CU2N option identify the complete ESB cable assembly?\u003c\/b\u003e The ordering code identifies an ESB bus connector unit. It does not confirm every required cable or accessory. Verify the complete connection arrangement against the system drawings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e5. Which details should I send for a system compatibility check?\u003c\/b\u003e Provide the controller model, current ESB node type, bus arrangement, installed I\/O modules, supply voltage, and full ordering code. These details support a more reliable selection review.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/ANB10D-425.png?v=1792565224\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":67706776846518,"sku":"ANB10D-425\/CU2N","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/ANB10D-425-CU2N.jpg?v=1792565102","url":"https:\/\/www.plcsparehub.com\/products\/anb10d-425-cu2n-yokogawa-anb10d-esb-bus-node-unit","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}