{"product_id":"allen-bradley-1756-it6i2-controllogix-thermocouple-input-module","title":"Allen-Bradley 1756-IT6I2 ControlLogix Thermocouple Input Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Introduction\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1756-IT6I2\u003c\/strong\u003e is an enhanced thermocouple input module from the \u003cstrong\u003eRockwell Automation ControlLogix\u003c\/strong\u003e series. It provides six individually isolated analog input channels for temperature and millivolt measurements. The module supports multiple thermocouple types, including B, C, D, E, J, K, L, N, R, S, and T. Its 16-bit resolution enables detailed signal acquisition across configured input ranges. Two cold junction compensation (CJC) sensors support accurate thermocouple temperature conversion. Each CJC sensor provides an accuracy of ±0.3°C. The module uses sigma-delta analog-to-digital conversion and ITS-90 thermocouple linearization. Engineers can select integer or IEEE 32-bit floating-point data formats. The \u003cstrong\u003e1756-IT6I2\u003c\/strong\u003e also provides configurable filtering, wire-off detection, process alarms, and rate alarms. These functions help engineers monitor temperature signals and identify abnormal sensor conditions.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eRockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1756-IT6I2\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eControlLogix\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Thermocouple Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e6 individually isolated inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCJC Sensors\u003c\/td\u003e\n\u003ctd\u003e2 integrated CJC inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003eThermocouple and millivolt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resolution\u003c\/td\u003e\n\u003ctd\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh-Resolution Range\u003c\/td\u003e\n\u003ctd\u003e-12 to 30 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh-Resolution Sensitivity\u003c\/td\u003e\n\u003ctd\u003e0.7 µV\/bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Input Range\u003c\/td\u003e\n\u003ctd\u003e-12 to 78 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Range Sensitivity\u003c\/td\u003e\n\u003ctd\u003e1.4 µV\/bit typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003eGreater than 10 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Overvoltage Protection\u003c\/td\u003e\n\u003ctd\u003e120 VAC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple Linearization\u003c\/td\u003e\n\u003ctd\u003eITS-90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCJC Sensor Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.3°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOffset Drift\u003c\/td\u003e\n\u003ctd\u003e0.5 µV\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Bandwidth\u003c\/td\u003e\n\u003ctd\u003e15 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSettling Time\u003c\/td\u003e\n\u003ctd\u003eGreater than 80 ms to 5% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal-Mode Noise Rejection\u003c\/td\u003e\n\u003ctd\u003e60 dB at 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon-Mode Noise Rejection\u003c\/td\u003e\n\u003ctd\u003eMinimum 160 dB under specified test conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen-Circuit Detection\u003c\/td\u003e\n\u003ctd\u003ePositive full-scale indication within 2 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Formats\u003c\/td\u003e\n\u003ctd\u003eInteger and IEEE 32-bit floating point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Method\u003c\/td\u003e\n\u003ctd\u003eSigma-delta\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Power Dissipation\u003c\/td\u003e\n\u003ctd\u003e4.6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Dissipation\u003c\/td\u003e\n\u003ctd\u003e15.7 BTU\/hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current at 5V\u003c\/td\u003e\n\u003ctd\u003e200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current at 24V\u003c\/td\u003e\n\u003ctd\u003e150 mA (verify against the applicable hardware revision)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible RTB\u003c\/td\u003e\n\u003ctd\u003e1756-TBNH, 1756-TBSH (verify module-specific wiring compatibility)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eThermocouple Input Types and Measurement Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e1756-IT6I2\u003c\/strong\u003e supports eleven thermocouple types. Engineers can configure individual channels for different sensor types.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eThermocouple Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eType B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003ctd\u003eType D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE\u003c\/td\u003e\n\u003ctd\u003eType E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJ\u003c\/td\u003e\n\u003ctd\u003eType J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK\u003c\/td\u003e\n\u003ctd\u003eType K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eL\u003c\/td\u003e\n\u003ctd\u003eType L (TXK\/XK)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003ctd\u003eType N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eR\u003c\/td\u003e\n\u003ctd\u003eType R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS\u003c\/td\u003e\n\u003ctd\u003eType S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003ctd\u003eType T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe supported temperature range depends on the selected thermocouple type. The module converts measured millivolt signals into engineering temperature values. The two CJC sensors compensate for reference-junction temperature variations. Their specified accuracy is ±0.3°C.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSignal Processing and Diagnostic Functions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module provides configurable signal processing functions for industrial temperature monitoring.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput range selection:\u003c\/strong\u003e Supports multiple millivolt measurement ranges.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold junction compensation:\u003c\/strong\u003e Uses two CJC sensors for thermocouple measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNotch filtering:\u003c\/strong\u003e Helps suppress unwanted power-line frequency interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital filtering:\u003c\/strong\u003e Supports additional filtering in floating-point applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReal-time sampling:\u003c\/strong\u003e Provides periodic acquisition of channel data.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire-off detection:\u003c\/strong\u003e Identifies open thermocouple circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverrange detection:\u003c\/strong\u003e Identifies signals exceeding configured measurement limits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnderrange detection:\u003c\/strong\u003e Identifies signals below configured measurement limits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess alarms:\u003c\/strong\u003e Monitors configured temperature thresholds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRate alarms:\u003c\/strong\u003e Detects temperature changes that exceed configured rates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature units:\u003c\/strong\u003e Supports configurable temperature representation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10-ohm offset:\u003c\/strong\u003e Provides an additional configurable offset function.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eData Processing and Controller Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e1756-IT6I2\u003c\/strong\u003e transfers acquired channel values and diagnostic information through the ControlLogix backplane. It supports two data formats:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInteger mode:\u003c\/strong\u003e Uses left-justified, two's-complement data.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFloating-point mode:\u003c\/strong\u003e Uses IEEE 32-bit floating-point representation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe minimum module scan times depend on the selected format and measurement type.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Scan Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFloating-point, millivolt\u003c\/td\u003e\n\u003ctd\u003e25 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFloating-point, temperature\u003c\/td\u003e\n\u003ctd\u003e50 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInteger, millivolt\u003c\/td\u003e\n\u003ctd\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe module stores processed signals, diagnostic states, and configuration parameters in its data tables. ControlLogix programs can access these values for comparison instructions and arithmetic operations. Engineers can also use them in process alarms and temperature control algorithms.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eInstall the \u003cstrong\u003e1756-IT6I2\u003c\/strong\u003e in a compatible ControlLogix chassis. Follow these engineering recommendations:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the catalog number and chassis compatibility before installation.\u003c\/li\u003e\n\u003cli\u003eConfirm the available chassis slot and controller memory capacity.\u003c\/li\u003e\n\u003cli\u003eDisconnect power before installing or removing the module.\u003c\/li\u003e\n\u003cli\u003eUse the specified removable terminal block for field wiring.\u003c\/li\u003e\n\u003cli\u003eVerify RTB compatibility before selecting the 1756-TBNH or 1756-TBSH.\u003c\/li\u003e\n\u003cli\u003eConnect thermocouple wires using the correct polarity.\u003c\/li\u003e\n\u003cli\u003eUse suitable thermocouple extension wire for each sensor type.\u003c\/li\u003e\n\u003cli\u003eSeparate low-level thermocouple wiring from high-voltage conductors.\u003c\/li\u003e\n\u003cli\u003eCheck terminal tightness and wiring insulation.\u003c\/li\u003e\n\u003cli\u003eConfirm channel configuration before starting the measurement process.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor accurate temperature acquisition, maintain correct sensor polarity and cold junction compensation settings.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility and Selection Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e1756-IT6I2\u003c\/strong\u003e integrates with the Rockwell Automation ControlLogix platform. Before ordering, review these compatibility requirements:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eController platform:\u003c\/strong\u003e Confirm compatibility with the installed ControlLogix processor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis:\u003c\/strong\u003e Check available slots and chassis power capacity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring accessories:\u003c\/strong\u003e Verify the required RTB and terminal housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor selection:\u003c\/strong\u003e Match the configured input type with the thermocouple specification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal range:\u003c\/strong\u003e Select the correct millivolt range for the application.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoftware configuration:\u003c\/strong\u003e Confirm support for the module in the installed programming environment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData handling:\u003c\/strong\u003e Select integer or floating-point format according to controller requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe module supports standalone ControlLogix systems and distributed I\/O architectures. Actual installation limits depend on controller capacity and available chassis resources.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCertifications and Compliance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe supplied technical information does not identify specific certification numbers or approval marks for the \u003cstrong\u003e1756-IT6I2\u003c\/strong\u003e. Check the product nameplate and applicable Rockwell Automation documentation for the exact regulatory approvals. Verify project-specific requirements before installation in regulated or hazardous-area applications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eStandard product package description:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Allen-Bradley \u003cstrong\u003e1756-IT6I2 Thermocouple Input Module\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eTerminal block and wiring accessories: confirm separately when ordering\u003c\/li\u003e\n\u003cli\u003eProduct documentation: subject to the supplied package configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe removable terminal block may require separate ordering. Confirm whether the required 1756-TBNH or another approved accessory is included.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the primary function of the Allen-Bradley 1756-IT6I2?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module acquires thermocouple and millivolt signals through six individually isolated input channels. It converts these signals into digital values for ControlLogix temperature monitoring and process control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Which thermocouple types does the 1756-IT6I2 support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt supports B, C, D, E, J, K, L, N, R, S, and T thermocouples. Configure each channel according to its connected sensor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What is the difference between the two input ranges?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe high-resolution range covers -12 to 30 mV with 0.7 µV\/bit sensitivity. The standard range covers -12 to 78 mV with 1.4 µV\/bit typical sensitivity. Select the range according to the expected sensor signal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Why does this module include two CJC sensors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThermocouples require reference-junction compensation for accurate temperature conversion. The two CJC sensors measure reference-junction temperature conditions. Each sensor provides specified accuracy of ±0.3°C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What should engineers check when temperature readings fluctuate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStart by checking thermocouple polarity and terminal connections. Then inspect shielding, grounding, sensor condition, and CJC configuration. Incorrect sensor selection or electrical interference can also cause unstable readings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ6: Which removable terminal block should buyers select?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe supplied product information identifies the 1756-TBNH as the specified wiring accessory. It also mentions the 1756-TBSH. Confirm the exact RTB compatibility against the module revision and official wiring documentation before ordering.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ7: Can the 1756-IT6I2 detect a disconnected thermocouple?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The module provides wire-off detection and reports an open-circuit condition through its diagnostic functions. Its specified detection response reaches a positive full-scale reading within two seconds.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ8: Does the module support floating-point temperature data?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. It supports IEEE 32-bit floating-point data and integer data formats. Floating-point mode also supports the module's digital filtering function.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ9: How can engineers select a suitable replacement module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the exact catalog number, chassis compatibility, input channel requirements, thermocouple types, and RTB configuration. Also verify controller software support and existing channel configuration. Do not select a replacement solely by its six-channel input count.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ10: What should technicians verify before replacing an installed 1756-IT6I2?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecord the existing channel settings, thermocouple types, data format, filters, and alarm thresholds. Check the RTB wiring and controller configuration before removal. After installation, validate each channel against a known reference signal.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":45013989032118,"sku":"1756-IT6I2","price":177.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/1756-IT6I2.jpg?v=1795059577","url":"https:\/\/www.plcsparehub.com\/products\/allen-bradley-1756-it6i2-controllogix-thermocouple-input-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}