{"product_id":"afv10d-s41201-yokogawa-centum-vp-duplexed-field-control-unit","title":"AFV10D-S41201 Yokogawa CENTUM VP Duplexed Field Control Unit","description":"\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #d10000;\"\u003eAFV10D-S41201\u003c\/span\u003e | Yokogawa | Duplexed Field Control Unit\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #d10000;\"\u003eAFV10D-S41201\u003c\/span\u003e\u003c\/strong\u003e serves as the high-availability core for CENTUM VP systems.\u003c\/li\u003e\n\u003cli\u003eThis 19-inch rack-mountable unit manages high-speed communication via the Vnet\/IP network.\u003c\/li\u003e\n\u003cli\u003eIt ensures zero-downtime through a robust duplexed architecture and redundant power modules.\u003c\/li\u003e\n\u003cli\u003eEngineered for professional industrial environments requiring 32MB of protected main memory.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Engineering Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Yokogawa\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color: #d10000;\"\u003eAFV10D-S41201\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e CENTUM VP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessor:\u003c\/strong\u003e VR5432 (133 MHz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain Memory:\u003c\/strong\u003e 32 Mbyte with Battery Backup\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory Protection:\u003c\/strong\u003e Max 72 hours backup (Minimum 48h recharge time)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus Contact:\u003c\/strong\u003e 2 terminals (NC, C) rated at 30V DC, 0.3A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Interface:\u003c\/strong\u003e Dual-redundant Vnet\/IP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e Approximately 8 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Configuration Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan style=\"color: #d10000;\"\u003eAFV10D-S41201\u003c\/span\u003e\u003c\/strong\u003e Suffix Logic:\n\u003cul\u003e\n\u003cli\u003e↳ \u003cstrong\u003eS\u003c\/strong\u003e: Standard hardware type\u003c\/li\u003e\n\u003cli\u003e↳ \u003cstrong\u003e4\u003c\/strong\u003e: Dual-Redundant Vnet\/IP and Power Supply\u003c\/li\u003e\n\u003cli\u003e↳ \u003cstrong\u003e1\u003c\/strong\u003e: 100–120 V AC Power Input\u003c\/li\u003e\n\u003cli\u003e↳ \u003cstrong\u003e2\u003c\/strong\u003e: 220–240 V AC Power Input\u003c\/li\u003e\n\u003cli\u003e↳ \u003cstrong\u003e0\u003c\/strong\u003e: Basic system configuration\u003c\/li\u003e\n\u003cli\u003e↳ \u003cstrong\u003e1\u003c\/strong\u003e: LFS1500 Control Function (Vnet\/IP and FIO)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eInternal Module Slotting:\n\u003cul\u003e\n\u003cli\u003e↳ \u003cstrong\u003eSlots 7 \u0026amp; 8\u003c\/strong\u003e: Reserved for \u003cstrong\u003eEC401\u003c\/strong\u003e ESB Bus Couplers\u003c\/li\u003e\n\u003cli\u003e↳ \u003cstrong\u003eProcessor\u003c\/strong\u003e: Dual \u003cstrong\u003eCP451\u003c\/strong\u003e Modules (Duplexed Mode)\u003c\/li\u003e\n\u003cli\u003e↳ \u003cstrong\u003ePower\u003c\/strong\u003e: Dual \u003cstrong\u003ePW481 \/ PW482 \/ PW484\u003c\/strong\u003e Modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagnostic Capability \u0026amp; Typical Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #d10000;\"\u003eAFV10D-S41201\u003c\/span\u003e\u003c\/strong\u003e features a fail-open status contact for immediate fault notification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePetrochemical Refineries:\u003c\/strong\u003e Reliable management of high-density I\/O loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Generation:\u003c\/strong\u003e Precise coordination for turbine and boiler safety control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePharmaceutical Batching:\u003c\/strong\u003e Ensures data integrity and memory protection during power loss.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOffshore Platforms:\u003c\/strong\u003e Built to withstand harsh environments with G3-compliant standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u0026amp; Global Logistics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Standard 19-inch rack mounting with 8 x M5 screws and insulation bushes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e M4 screw terminal connections for power, grounding, and contact outputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12-month comprehensive quality guarantee.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch:\u003c\/strong\u003e Fast shipping within 24 to 48 hours.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCourier:\u003c\/strong\u003e Worldwide delivery via FedEx, UPS, or DHL Express.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePurchasing \u0026amp; Selection Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAlways match the suffix code to your site voltage (100-120V vs 220-240V).\u003c\/li\u003e\n\u003cli\u003eThe standard LFS1500 license supports 3 nodes; upgrade to LFS1550 for up to 14 nodes.\u003c\/li\u003e\n\u003cli\u003eEnsure \u003cstrong\u003eEC401\u003c\/strong\u003e modules are installed in both slots 7 and 8 for processor redundancy.\u003c\/li\u003e\n\u003cli\u003eVerify that the control cabinet can support the 8kg unit weight and adequate cooling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eProfessional FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eHow does the CP451 redundancy function in this unit?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eTwo \u003cstrong\u003eCP451\u003c\/strong\u003e modules run in parallel; if the active unit fails, the standby takes over in milliseconds.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWhat is the recharge requirement for the memory battery?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eThe battery requires a minimum of 48 hours of continuous power to provide the full 72-hour backup.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCan I expand the node capacity beyond 3 units?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eYes, while LFS1500 supports 3 nodes, adding the LFS1550 package allows expansion up to 14 nodes.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWhat happens to the status contact during an FCU failure?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #d10000;\"\u003eAFV10D-S41201\u003c\/span\u003e\u003c\/strong\u003e status contact (NC) will open, triggering your external alarm system.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eIs this unit compatible with ER bus nodes?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eYes, by installing the \u003cstrong\u003eEB401\u003c\/strong\u003e Interface Master Module in the appropriate odd-numbered slots.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":45014045917366,"sku":"AFV10D-S41201","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/AFV10D-S41201_70adbb73-6c4f-460c-9d17-2be5da5ad748.jpg?v=1775548352","url":"https:\/\/www.plcsparehub.com\/products\/afv10d-s41201-yokogawa-centum-vp-duplexed-field-control-unit","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}