{"product_id":"adv561-p50-yokogawa-adv561-series-isolated-24v-dc-output-module","title":"ADV561-P50 Yokogawa ADV561 Series Isolated 24V DC Output Module","description":"\u003ch3\u003e\u003cstrong\u003eADV561-P50 | Yokogawa 64-Channel Digital Output Module\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #1677c8;\"\u003eYokogawa ADV561-P50\u003c\/span\u003e\u003c\/strong\u003e is a 64-channel digital output module designed for industrial control and distributed control system applications. It provides 24 V DC current-sink outputs and supports status output, one-shot pulse generation, and time-proportioning control. The \u003cstrong\u003eADV561 series\u003c\/strong\u003e combines standard ON\/OFF switching with configurable pulse output functions. Its pulse-width range extends from 8 ms to 7200 seconds, supporting applications that require timed switching rather than simple continuous output states. Engineers can use this module to control compatible field loads, execute timed output sequences, and support time-proportioning strategies. Before installation, verify load current, external supply capacity, wiring polarity, and controller compatibility.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e01 | Electrical Specifications and Output Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComplete Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #1677c8;\"\u003eADV561-P50\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eADV561\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Applied Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCurrent sink\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal Power Supply Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC, 100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal Supply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20.4–26.4 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Output ON Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum OFF-State Leakage Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Load Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mA per channel at 26.4 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatus Output Response Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMixed Status and Pulse Output Response Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePulse Width Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 ms to 7200 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePulse Width Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 ms, with an additional ON\/OFF delay of up to 1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput-to-System Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 kV AC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommon-to-Common Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC for 1 minute; common negative side arranged every 16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum 5 V DC Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e700 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal Supply Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDedicated AKB337 cable or MIL connector cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eLoad-design note:\u003c\/strong\u003e The 100 mA rating applies to each output channel at 26.4 V DC. Verify aggregate loading and the manufacturer's common-group restrictions before energizing all channels.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e02 | Model Configuration Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCode Segment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDefinition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEngineering Meaning\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eADV561\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64-channel digital output module\u003c\/td\u003e\n\u003ctd\u003eIdentifies the module family and its output function.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-P\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePulse-width output and time-proportioning output functions\u003c\/td\u003e\n\u003ctd\u003eSupports one-shot pulse generation and time-proportioning ON\/OFF control.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout status display and without explosion protection\u003c\/td\u003e\n\u003ctd\u003eDefines the specified status-display and protection configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic type\u003c\/td\u003e\n\u003ctd\u003eIdentifies the basic configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComplete Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #1677c8;\"\u003eADV561-P50\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpecifies the complete module configuration for ordering and replacement checks.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration tip:\u003c\/strong\u003e Match the complete model code with the installed module. Do not assume every ADV561 variant supports the same pulse functions or interface configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e03 | Output Functions and Timing Behavior\u003c\/strong\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus output\u003c\/strong\u003e The module provides ON\/OFF output control for compatible field loads. Its specified status-output response time is 3 ms maximum.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOne-shot pulse output\u003c\/strong\u003e The pulse-width function generates timed output pulses. The supported pulse width ranges from 8 ms to 7200 seconds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime-proportioning output\u003c\/strong\u003e The module switches outputs according to time-proportioning commands. This function can support applications that regulate average operating time through controlled ON\/OFF intervals.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe pulse-width resolution is 8 ms. An additional ON\/OFF delay of up to 1 ms applies, so engineers should account for this delay when designing timing-sensitive sequences. The 10 ms maximum response specification applies to mixed status and pulse outputs. Verify the applicable operating mode before calculating system response timing.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e04 | Industrial Equipment and Application Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication Area\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Engineering Use\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSolenoid valve manifolds\u003c\/td\u003e\n\u003ctd\u003eControls compatible 24 V DC valve coils within channel-current limits.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMachine sequencing\u003c\/td\u003e\n\u003ctd\u003eIssues discrete ON\/OFF commands to actuators and auxiliary devices.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimed dosing equipment\u003c\/td\u003e\n\u003ctd\u003eGenerates controlled output pulses for compatible dosing or dispensing mechanisms.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess time-proportioning\u003c\/td\u003e\n\u003ctd\u003eSupports timed switching strategies for suitable process-control devices.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial interlocks\u003c\/td\u003e\n\u003ctd\u003eProvides controller-commanded output states for compatible control sequences.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDistributed control systems\u003c\/td\u003e\n\u003ctd\u003eConsolidates multiple discrete output commands within a supported Yokogawa architecture.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eApplication caution:\u003c\/strong\u003e Time-proportioning output does not automatically provide closed-loop regulation. The controller and process strategy must supply the required control logic.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e05 | Wiring and Installation Planning\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify load type:\u003c\/strong\u003e Confirm that each field device accepts the module's current-sink output configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck voltage:\u003c\/strong\u003e Keep the external supply within 20.4–26.4 V DC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLimit channel current:\u003c\/strong\u003e Keep each load within the specified 100 mA maximum at 26.4 V DC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReview OFF-state leakage:\u003c\/strong\u003e Check whether the connected load tolerates up to 0.1 mA leakage current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm connection hardware:\u003c\/strong\u003e Use the specified AKB337 dedicated cable or compatible MIL connector cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReview common wiring:\u003c\/strong\u003e Follow the manufacturer's common-group arrangement and grounding instructions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlan power capacity:\u003c\/strong\u003e Account for the module's stated internal and external supply current requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect field wiring:\u003c\/strong\u003e Check conductor sizing, terminal condition, cable routing, and load polarity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIsolate power according to site procedures before connecting or removing field wiring. Consult the Yokogawa installation manual for pin assignments, cable details, and approved load connections.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e06 | Commissioning and Diagnostic Workflow\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eADV561-P50\u003c\/strong\u003e supports output verification through status switching and pulse timing tests. Engineers should verify both the controller command and the actual electrical response.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck supply voltage:\u003c\/strong\u003e Measure the external supply under the expected operating load.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest a single channel:\u003c\/strong\u003e Command an output and verify the corresponding field-device response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasure ON voltage:\u003c\/strong\u003e Confirm that the output voltage drop remains within the specified maximum under the test conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck OFF-state behavior:\u003c\/strong\u003e Investigate unexpected load activation and consider the specified leakage current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify pulse timing:\u003c\/strong\u003e Compare the commanded pulse width with the measured output waveform.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest mixed operation:\u003c\/strong\u003e Confirm timing behavior when status and pulse outputs operate together.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReview the load circuit:\u003c\/strong\u003e Inspect wiring, coil resistance, protective components, and external supply stability.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eField example:\u003c\/strong\u003e A solenoid valve responds correctly to continuous ON\/OFF commands but misses short pulses. An engineer measures the output waveform and checks whether the commanded pulse meets the 8 ms minimum. The engineer then evaluates the load response and the additional ON\/OFF delay. \u003cstrong\u003eDiagnostic limitation:\u003c\/strong\u003e The supplied specifications do not define onboard diagnostic codes or independent load-failure detection. Use the host system's documented diagnostics and electrical measurements to isolate faults.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e07 | Compatibility and Load Selection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eBefore selecting the \u003cstrong\u003eADV561-P50\u003c\/strong\u003e, verify these application requirements:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe target Yokogawa system supports the ADV561 series and its selected output configuration.\u003c\/li\u003e\n\u003cli\u003eThe field devices accept current-sink outputs and the specified 24 V DC operating conditions.\u003c\/li\u003e\n\u003cli\u003eEach channel remains within the 100 mA maximum load-current rating.\u003c\/li\u003e\n\u003cli\u003eThe external supply remains within the 20.4–26.4 V DC range.\u003c\/li\u003e\n\u003cli\u003eThe load tolerates the specified OFF-state leakage current and output voltage behavior.\u003c\/li\u003e\n\u003cli\u003eThe application requires pulse-width or time-proportioning functionality.\u003c\/li\u003e\n\u003cli\u003eThe required installation does not depend on explosion protection from this configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEngineering selection tip:\u003c\/strong\u003e Check the field device's inrush current, steady-state current, and inductive characteristics. A load's nominal current alone may not establish suitability. Confirm any required suppression components and switching restrictions through the manufacturer's documentation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e08 | Global PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eFrom an engineering perspective, the \u003cstrong\u003eADV561-P50\u003c\/strong\u003e combines high-density output switching with pulse timing functions. Its 64 channels can reduce the number of output modules required in suitable control-system designs. The main selection risks involve load compatibility, output timing, and power distribution. A nominally compatible 24 V DC solenoid can still exceed the channel rating during energization. A short pulse can also fail to operate a mechanical device even when the output waveform appears correct. During commissioning, test representative loads before enabling a full group of outputs. Measure pulse duration at the field connection rather than relying only on controller commands. For replacement work, verify the complete suffix code, cable type, and controller configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e09 | Environmental and Compliance Considerations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe suffix code \u003cstrong\u003e5\u003c\/strong\u003e identifies a configuration without status display and without explosion protection, according to the supplied model information. The supplied specifications do not state a specific operating temperature range, ingress-protection rating, EMC certification, or hazardous-area approval. Verify the required environmental and regulatory conditions against the manufacturer's documentation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e10 | Packaging, Shipping, and Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct:\u003c\/strong\u003e Yokogawa ADV561-P50 digital output module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection accessories:\u003c\/strong\u003e Confirm whether the required AKB337 cable or MIL connector cable is included.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging contents:\u003c\/strong\u003e Subject to the confirmed order configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping options:\u003c\/strong\u003e FedEx, UPS, and DHL, subject to destination and service availability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch target:\u003c\/strong\u003e Typically 24–48 hours after order confirmation, subject to stock and payment verification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12 months, subject to the seller's written warranty terms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eContact Global PLC Spare HUB to confirm stock, cable requirements, dispatch timing, and warranty coverage before ordering.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e11 | Frequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1. Why might a connected solenoid remain energized after the output turns OFF?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the field wiring, external supply, load characteristics, and possible parallel current paths. The module specifies up to 0.1 mA OFF-state leakage, so confirm that the load tolerates this value.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2. How should I choose between standard status output and pulse-width output?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse status output for normal ON\/OFF commands. Select pulse-width output when the application needs a defined pulse duration. Verify minimum pulse width, output delay, and the field device's mechanical response.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3. What should I investigate when output timing differs from the controller command?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMeasure the waveform at the field connection and compare it with the configured pulse width. Consider the stated 8 ms resolution, possible delay of up to 1 ms, and the applicable response-time specification.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4. Can all 64 outputs operate at their maximum load current simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe supplied data gives a maximum of 100 mA per channel but does not establish the full simultaneous-load or common-group limits. Verify aggregate loading, thermal restrictions, and power-distribution requirements in the official manual.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5. What details should I provide when sourcing a replacement for an existing output module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eProvide the full model number, host-system configuration, field-load types, cable arrangement, and required pulse functions. Include load-current details when possible so the supplier can help check application suitability.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eRequest a Quote for ADV561-P50\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNeed a \u003cstrong\u003e\u003cspan style=\"color: #1677c8;\"\u003eYokogawa ADV561-P50\u003c\/span\u003e\u003c\/strong\u003e for a control-system upgrade, output replacement, or timed switching application? Contact \u003cstrong\u003eGlobal PLC Spare HUB\u003c\/strong\u003e with the complete model number, required quantity, host-system details, and delivery destination. Our team can help review configuration requirements and confirm shipping options through FedEx, UPS, or DHL.\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/ADV161_ADV561_dd7d7f39-0815-4da6-8114-931f3440db4b.png?v=1792568071\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":67707470839990,"sku":"ADV561-P50","price":152.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/ADV561-P50.jpg?v=1792568071","url":"https:\/\/www.plcsparehub.com\/products\/adv561-p50-yokogawa-adv561-series-isolated-24v-dc-output-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}