{"product_id":"adv151-p50-d5a00-yokogawa-adv151-series-digital-input-module","title":"ADV151-P50\/D5A00 Yokogawa ADV151 Series Digital Input Module","description":"\u003ch3\u003e\u003cstrong\u003eADV151-P50\/D5A00 | Yokogawa 32-Channel Digital Input Module\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #1677c8;\"\u003eYokogawa ADV151-P50\/D5A00\u003c\/span\u003e\u003c\/strong\u003e is a 32-channel digital input module designed for industrial control and distributed control system applications. It accepts 24 V DC sink\/source signals and supports status monitoring, pushbutton edge counting, and sequence of events (SOE) data capture. The \u003cstrong\u003eADV151 series\u003c\/strong\u003e provides an input response time of 8 ms or less for status signals. Its pushbutton input function supports a minimum ON detection time of 20 ms and a maximum ON\/OFF cycle of 25 Hz. This configuration includes a \u003cstrong\u003eKS cable interface adapter, model ATD5A-00\u003c\/strong\u003e, for 32-channel digital input connections. Engineers should verify the host system, cable arrangement, and input logic before installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e01 | Engineering Specifications at a Glance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComplete Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #1677c8;\"\u003eADV151-P50\/D5A00\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eADV151\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC, sink\/source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ON Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18–26.4 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput OFF Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.0 V DC or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.1 mA ±20% per channel at rated input voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Allowable Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30.0 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput-to-System Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 kV AC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommon-to-Common Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC for 1 minute; one common per 16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatus Input Response Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Pushbutton ON Detection Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Pushbutton ON\/OFF Cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 mA at 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePressure clamp terminal, dedicated AKB331 cable, or MIL connector cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface Adapter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKS cable interface adapter, model ATD5A-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification note:\u003c\/strong\u003e The supplied data does not state analog measurement range, frequency response, linearity, or resolution. These parameters do not directly apply to this discrete digital input module.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e02 | Model Configuration and Suffix Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCode Segment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDefinition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEngineering Significance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eADV151\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital Input Module\u003c\/td\u003e\n\u003ctd\u003eIdentifies the 32-channel digital input module family.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWith pushbutton input\u003c\/td\u003e\n\u003ctd\u003eSupports pushbutton edge counting in addition to status input functions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout status display; without explosion protection\u003c\/td\u003e\n\u003ctd\u003eIdentifies the specified display and protection configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic type\u003c\/td\u003e\n\u003ctd\u003eIdentifies the basic configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\/D5A00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKS cable interface adapter for 32-channel digital input\u003c\/td\u003e\n\u003ctd\u003eSpecifies the ATD5A-00 interface adapter configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComplete Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #1677c8;\"\u003eADV151-P50\/D5A00\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIdentifies the full module and interface configuration for ordering and replacement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering recommendation:\u003c\/strong\u003e Verify the complete model code and adapter requirement against the installed hardware. Do not assume another ADV151 configuration includes the same interface accessories.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e03 | Three Input Functions for Control and Event Acquisition\u003c\/strong\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus input\u003c\/strong\u003e The module detects ON\/OFF states from connected field contacts or compatible 24 V DC signals. Its maximum response time is 8 ms for status input.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePushbutton input\u003c\/strong\u003e The module supports pushbutton edge counting. The specified minimum ON detection time is 20 ms, with a maximum ON\/OFF cycle of 25 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSequence of Events input\u003c\/strong\u003e The module supports SOE data capture for applications that require event records. Confirm timestamp handling, time resolution, synchronization, and system-level SOE behavior in the applicable Yokogawa documentation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThese functions serve different engineering purposes. Status input monitors operating conditions, pushbutton input counts transitions, and SOE input supports event analysis.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e04 | Typical Equipment and Application Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePractical Use\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDCS field status acquisition\u003c\/td\u003e\n\u003ctd\u003eCollects discrete signals from auxiliary contacts, relays, and limit switches.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eValve and actuator feedback\u003c\/td\u003e\n\u003ctd\u003eMonitors open\/closed indications and operating-state contacts.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump and motor systems\u003c\/td\u003e\n\u003ctd\u003eAcquires running, stopped, and auxiliary contact signals.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperator pushbutton stations\u003c\/td\u003e\n\u003ctd\u003eCounts pushbutton transitions within the supported timing limits.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess event monitoring\u003c\/td\u003e\n\u003ctd\u003eSupports SOE data capture for event investigation and sequence analysis.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial interlock systems\u003c\/td\u003e\n\u003ctd\u003eProvides discrete input states for controller-based permissive logic.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe module does not independently execute all control logic or guarantee safety-rated protection. Confirm the host system's supported functions and applicable safety requirements before assigning it to critical interlocks.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e05 | Wiring and Installation Planning\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm input logic:\u003c\/strong\u003e Check whether the field device and circuit require sink or source wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify signal voltage:\u003c\/strong\u003e Ensure ON signals meet the 18–26.4 V DC range and OFF signals meet the 5.0 V DC maximum.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRespect voltage limits:\u003c\/strong\u003e Do not exceed the 30.0 V DC maximum allowable input voltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelect the correct interface:\u003c\/strong\u003e Confirm the ATD5A-00 adapter and the required pressure clamp, AKB331, or MIL cable connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck common grouping:\u003c\/strong\u003e Account for the specified common arrangement, with one common per 16 channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect wiring:\u003c\/strong\u003e Check terminal security, conductor condition, labeling, and separation from noise-producing circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify channel mapping:\u003c\/strong\u003e Compare field terminal assignments with the control-system configuration before energizing the circuit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFollow the approved Yokogawa installation manual for terminal assignments, mounting procedures, and connection restrictions. Isolate power according to site procedures before handling field wiring.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e06 | Commissioning and Diagnostic Workflow\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eADV151-P50\/D5A00\u003c\/strong\u003e supports structured input verification through its status, pushbutton, and SOE functions.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eEstablish a baseline:\u003c\/strong\u003e Record the expected state of each connected field contact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest status signals:\u003c\/strong\u003e Operate field devices and confirm that the controller reports the corresponding input state.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck voltage thresholds:\u003c\/strong\u003e Measure the field signal when an input fails to change state.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify pushbutton timing:\u003c\/strong\u003e Confirm that ON duration and switching frequency remain within the specified limits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReview SOE records:\u003c\/strong\u003e Compare recorded events with the actual test sequence and available system time references.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect wiring and configuration:\u003c\/strong\u003e Check channel mapping, common connections, adapter installation, and controller settings.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eField example:\u003c\/strong\u003e A pushbutton press fails to register during a commissioning test. The engineer measures the contact pulse and finds an ON duration shorter than 20 ms. The engineer then checks the pushbutton mechanism and test setup before investigating module hardware. \u003cstrong\u003eDiagnostic limitation:\u003c\/strong\u003e The specifications confirm input functions and timing limits, but they do not define onboard fault codes or independent wire-break detection. Use the host system's documented diagnostics for additional fault isolation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e07 | Compatibility and Replacement Guidance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eBefore purchasing this configuration, verify the following:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe target Yokogawa system supports the ADV151 module and its intended application.\u003c\/li\u003e\n\u003cli\u003eThe system accepts the specified 32-channel input arrangement.\u003c\/li\u003e\n\u003cli\u003eThe field circuit supports 24 V DC sink\/source input requirements.\u003c\/li\u003e\n\u003cli\u003eThe installed interface uses the correct ATD5A-00 adapter or an approved alternative.\u003c\/li\u003e\n\u003cli\u003eThe application requires the pushbutton input and SOE capabilities provided by the selected configuration.\u003c\/li\u003e\n\u003cli\u003eThe installation does not require explosion protection from this configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eReplacement tip:\u003c\/strong\u003e Record the full model code, adapter designation, terminal arrangement, and controller channel mapping before removing the existing unit. This information helps prevent wiring errors and configuration mismatches during recommissioning.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e08 | Global PLC Spare HUB Review\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eFrom an engineering perspective, the key advantage of the \u003cstrong\u003eADV151-P50\/D5A00\u003c\/strong\u003e is its combination of 32-channel status acquisition, pushbutton edge counting, and SOE support. These functions serve different operational needs. A valve limit switch requires reliable state acquisition, while an operator pushbutton may require transition counting. An event-analysis application may also need SOE records to reconstruct the order of field changes. During troubleshooting, engineers should verify electrical thresholds and timing requirements before replacing the module. A short pushbutton pulse, incorrect sink\/source wiring, or mismatched channel assignment can create symptoms that resemble hardware failure. For replacement projects, confirm the \u003cstrong\u003eATD5A-00\u003c\/strong\u003e interface adapter and complete suffix code. This check reduces procurement errors and helps preserve the intended wiring arrangement.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e09 | Environmental and Compliance Considerations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe suffix code \u003cstrong\u003e5\u003c\/strong\u003e identifies a configuration without status display and without explosion protection, according to the supplied model description. The provided specifications do not establish a separate operating temperature range, ingress-protection rating, EMC certification, or hazardous-area approval. Verify the manufacturer's documentation against the site's environmental and regulatory requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e10 | Packaging, Shipping, and Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct:\u003c\/strong\u003e Yokogawa ADV151-P50\/D5A00 digital input module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecified interface adapter:\u003c\/strong\u003e KS cable interface adapter, model ATD5A-00.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOther accessories:\u003c\/strong\u003e Confirm cables, terminals, and mounting hardware against the order confirmation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping methods:\u003c\/strong\u003e FedEx, UPS, and DHL, subject to destination and service availability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch target:\u003c\/strong\u003e Typically 24–48 hours after order confirmation, subject to stock and payment verification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12 months, subject to the seller's written warranty terms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eContact Global PLC Spare HUB to verify stock, included accessories, delivery arrangements, and warranty coverage before ordering.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e11 | Frequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1. How do I determine whether a field signal meets the module's ON threshold?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMeasure the voltage at the relevant input under operating conditions. The specified ON range is 18–26.4 V DC. Also check common wiring and the field device's output behavior.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2. Why can a pushbutton counter miss rapid operator actions?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe input function specifies a minimum ON detection time of 20 ms and a maximum ON\/OFF cycle of 25 Hz. Shorter pulses or faster transitions may fall outside the stated operating limits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3. What should I verify when replacing an ADV151 module with an existing cable assembly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConfirm the complete suffix code, ATD5A-00 adapter requirement, connector type, channel assignments, and wiring diagram. Check that the replacement configuration matches the existing hardware and intended functions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4. How can SOE functionality help investigate intermittent process trips?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSOE records can help engineers compare event sequences and identify which input changes occurred before a trip. Reliable conclusions also depend on system time synchronization, event resolution, and the controller's diagnostic capabilities.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5. Is this configuration suitable for a hazardous industrial area?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe supplied suffix definition states that code 5 provides no explosion protection. Verify area classification and required approvals before selecting the module for hazardous locations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eRequest a Quote for ADV151-P50\/D5A00\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNeed a \u003cstrong\u003e\u003cspan style=\"color: #1677c8;\"\u003eYokogawa ADV151-P50\/D5A00\u003c\/span\u003e\u003c\/strong\u003e for a DCS upgrade, maintenance project, or replacement requirement? Contact \u003cstrong\u003eGlobal PLC Spare HUB\u003c\/strong\u003e with the full model code, required quantity, host-system details, and delivery destination. Our team can help review configuration requirements and confirm shipping options through FedEx, UPS, or DHL.\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/ADV151_ADV551_aac20101-49b7-4396-b95b-fc5e7acd70da.png?v=1792567044\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":67706907328694,"sku":"ADV151-P50\/D5A00","price":163.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/ADV151-P50-D5A00_6ffe883f-ffad-438d-b611-2de08ef174a3.jpg?v=1792567098","url":"https:\/\/www.plcsparehub.com\/products\/adv151-p50-d5a00-yokogawa-adv151-series-digital-input-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}