{"product_id":"abb-tb826-optical-media-converter-abb-3bse061637r1-s800-i-o","title":"ABB TB826 Optical Media Converter | ABB 3BSE061637R1 S800 I\/O","description":"\u003ch3\u003e\u003cstrong\u003eEngineering Synopsis\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003eABB 3BSE061637R1\u003c\/strong\u003e (\u003cstrong style=\"color: #0056b3;\"\u003eTB826\u003c\/strong\u003e) is a long-range optical media converter engineered specifically for the \u003cstrong style=\"color: #0056b3;\"\u003eS800 I\/O\u003c\/strong\u003e and \u003cstrong style=\"color: #0056b3;\"\u003eS800L\u003c\/strong\u003e distributed control ecosystem. Operating as a slave node on the ModuleBus, this DIN-rail mounted module bridges local plastic\/HCS versatile link fiber optics with high-capacity single-mode field fiber systems utilizing SC connectors, enabling cluster bus extension up to 5,000 meters in star topologies.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003ePerformance Matrix \u0026amp; Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003e\u003cstrong\u003eTechnical Attribute\u003c\/strong\u003e\u003c\/th\u003e\n      \u003cth\u003e\u003cstrong\u003eEngineering Specification\u003c\/strong\u003e\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer Brand \u0026amp; Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cstrong style=\"color: #0056b3;\"\u003eABB\u003c\/strong\u003e — \u003cstrong style=\"color: #0056b3;\"\u003eS800 I\/O\u003c\/strong\u003e \/ S800L System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCatalog Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cstrong style=\"color: #0056b3;\"\u003e3BSE061637R1\u003c\/strong\u003e (Model \u003cstrong style=\"color: #0056b3;\"\u003eTB826\u003c\/strong\u003e)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDevice Classification\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLong-Range Optical Media Converter (ModuleBus Slave)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFiber Conversion Media\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePlastic \/ HCS fiber (Versatile Link) to Single-Mode glass fiber (SC Connector)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Bus Extension\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUp to 5,000 meters per cluster in star configuration\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTypical 96 mA at 24 VDC supply voltage\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDIN Rail \u0026amp; Enclosure Specs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eS800L compact mechanics; IP20 protection class (EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePhysical Dimensions \u0026amp; Mass\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e85.6 mm (W) × 136 mm (H including latch) × 58.5 mm (D); Mass: 0.21 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eThermal Operating Limits\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0°C to +55°C operational (+5°C to +55°C approved); Storage: -40°C to +70°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEnvironmental \u0026amp; Corrosion\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eISA-S71.04 G3 harsh corrosion protection; Pollution Degree 2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHazardous Area Approvals\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ecULus Class I Div 2, Class I Zone 2, and ATEX Zone 2 certified\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cstrong\u003ePhysical Integration \u0026amp; Deployment Procedure\u003c\/strong\u003e\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVerify Vertical Mounting Derating:\u003c\/strong\u003e Ensure ambient temperatures remain at or below 40°C if mounting the \u003cstrong style=\"color: #0056b3;\"\u003eTB826\u003c\/strong\u003e vertically in dense marshalling cabinets.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSnap onto DIN Rail:\u003c\/strong\u003e Secure the \u003cstrong style=\"color: #0056b3;\"\u003e3BSE061637R1\u003c\/strong\u003e housing firmly onto standard DIN mounting rails within the S800L I\/O node enclosure.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTerminate 24V Power:\u003c\/strong\u003e Connect isolated 24VDC supply leads, verifying current delivery headroom for the typical 96 mA load.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePlug Optical Jumpers:\u003c\/strong\u003e Mate versatile link plastic\/HCS fibers from parent controllers and single-mode SC fiber cables for long-haul runs.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003e\u003cstrong\u003eDiagnostics \u0026amp; Maintenance Protocols\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOptical Attenuation Check:\u003c\/strong\u003e Monitor single-mode SC link signal strength periodically to prevent excessive insertion loss over 5 km runs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eG3 Corrosion Inspection:\u003c\/strong\u003e Verify cabinet air filtration during scheduled turnarounds to maintain ISA-S71.04 G3 corrosion resistance in chemical plants.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCluster Status Verification:\u003c\/strong\u003e Check controller diagnostic LEDs to ensure error-free ModuleBus packet transmission across star-configured clusters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eSystem Compatibility \u0026amp; Compliance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eController Interoperability:\u003c\/strong\u003e Fully compatible with ABB HI Controllers and standard S800 ModuleBus master interfaces.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGlobal Standards:\u003c\/strong\u003e Complies with EN\/UL 61010-1 electrical safety directives, EU\/CN\/UAE RoHS, and WEEE regulations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 × \u003cstrong style=\"color: #0056b3;\"\u003eABB 3BSE061637R1 TB826\u003c\/strong\u003e Optical Media Converter Unit\u003c\/li\u003e\n  \u003cli\u003eDust caps for SC optical transceiver ports\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eEngineering Selection Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSpecify the \u003cstrong style=\"color: #0056b3;\"\u003e3BSE061637R1\u003c\/strong\u003e converter when remote \u003cstrong style=\"color: #0056b3;\"\u003eS800 I\/O\u003c\/strong\u003e racks exceed standard copper or plastic fiber distance limits, requiring single-mode glass fiber distribution up to 5 km. Note that this unit does not support hot-swapping or line\/module redundancy.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Why does the TB826 restrict vertical mounting operating temperatures to +40°C compared to +55°C horizontally?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: Vertical orientation restricts natural convective airflow across the S800L plastic housing, necessitating a lower ambient ceiling to prevent internal electronic component thermal stress.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: Can the 3BSE061637R1 module be hot-swapped on an active S800 ModuleBus cluster?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: No, the TB826 lacks hot-swap capabilities; power must be isolated from the node before extracting or inserting the unit on the DIN rail.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: What precise fiber optic connector types are supported on both sides of this media converter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: The local side utilizes versatile link connectors for plastic or HCS fibers, while the remote long-haul side features standard SC connectors for single-mode glass fiber.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ4: How does the ISA-S71.04 G3 corrosion rating protect the unit in harsh chemical environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA4: G3 conformal coating on internal PCB traces prevents atmospheric sulfur and chlorine compounds from causing micro-corrosion and electrical bridging on circuit traces.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ5: What troubleshooting steps should I take if ModuleBus communication drops across a 4 km single-mode link?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA5: Inspect SC patch cords for microscopic dust contamination, use an optical time-domain reflectometer (OTDR) to check for macro-bends in the fiber run, and verify that received optical power matches transceiver receiver sensitivity thresholds.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":68078291353782,"sku":"3BSE061637R1","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/3BSE061637R1-3.jpg?v=1794810847","url":"https:\/\/www.plcsparehub.com\/products\/abb-tb826-optical-media-converter-abb-3bse061637r1-s800-i-o","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}