{"product_id":"abb-do05-symphony-plus-16-channel-relay-output-module","title":"ABB DO05 Symphony Plus 16-Channel Relay Output Module","description":"\u003ch3\u003e\u003cb\u003e\u003cspan style=\"color:#003366;\"\u003eProduct Overview\u003c\/span\u003e\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cb\u003e\u003cspan style=\"color:#003366;\"\u003e8VZZ000167H1\u003c\/span\u003e\u003c\/b\u003e model represents the \u003cb\u003e\u003cspan style=\"color:#003366;\"\u003eDO05\u003c\/span\u003e\u003c\/b\u003e digital output module from the \u003cb\u003e\u003cspan style=\"color:#003366;\"\u003eABB Symphony Plus SD\u003c\/span\u003e\u003c\/b\u003e series. Engineers deploy this unit in distributed control systems for reliable industrial automation switching. Sixteen electromechanical relay channels handle discrete control tasks efficiently. The active lifecycle status ensures long-term system support and availability for modern plant operations.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cb\u003e\u003cspan style=\"color:#003366;\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse: collapse; width: 100%;\"\u003e\n  \u003ctr\u003e\n    \u003cth\u003e\u003cb\u003eParameter Category\u003c\/b\u003e\u003c\/th\u003e\n    \u003cth\u003e\u003cb\u003eSpecification Details\u003c\/b\u003e\u003c\/th\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cb\u003eBrand \u0026amp; Series\u003c\/b\u003e\u003c\/td\u003e\n    \u003ctd\u003e\n\u003cb\u003e\u003cspan style=\"color:#003366;\"\u003eABB\u003c\/span\u003e\u003c\/b\u003e | \u003cb\u003e\u003cspan style=\"color:#003366;\"\u003eSymphony Plus SD Series\u003c\/span\u003e\u003c\/b\u003e\n\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cb\u003eModel \u0026amp; Order No.\u003c\/b\u003e\u003c\/td\u003e\n    \u003ctd\u003eModel: \u003cb\u003e\u003cspan style=\"color:#003366;\"\u003eDO05\u003c\/span\u003e\u003c\/b\u003e | Part Number: \u003cb\u003e\u003cspan style=\"color:#003366;\"\u003e8VZZ000167H1\u003c\/span\u003e\u003c\/b\u003e\n\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cb\u003eChannel Configuration\u003c\/b\u003e\u003c\/td\u003e\n    \u003ctd\u003e16 independent electromechanical relay digital output channels.\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cb\u003eContact Configuration\u003c\/b\u003e\u003c\/td\u003e\n    \u003ctd\u003eForm C (SPDT) silver tin oxide contacts with selectable NO or NC jumper settings.\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cb\u003eSwitching Capacity\u003c\/b\u003e\u003c\/td\u003e\n    \u003ctd\u003eSupports 3.0 A at 24 VDC, 1.0 A at 48 VDC, 250 mA at 125 VDC, and 3.0 A at 120 VAC.\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cb\u003eSensitivity \u0026amp; Resolution\u003c\/b\u003e\u003c\/td\u003e\n    \u003ctd\u003eMinimum switching load operates at 50 mA and 10 V. Discrete 16-bit channel state control.\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cb\u003eElectrical Isolation\u003c\/b\u003e\u003c\/td\u003e\n    \u003ctd\u003eWithstands 1500 V isolation voltage between channels for 1 minute.\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cb\u003eReliability \u0026amp; MTBF\u003c\/b\u003e\u003c\/td\u003e\n    \u003ctd\u003eCalculated MTBF reaches 364,666 hours per MIL-HDBK-217-FN2. MTTR equals 1 hour.\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cb\u003eEnvironmental Tolerance\u003c\/b\u003e\u003c\/td\u003e\n    \u003ctd\u003eDesigned for standard industrial control room and cabinet operating environments.\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cb\u003ePhysical Dimensions\u003c\/b\u003e\u003c\/td\u003e\n    \u003ctd\u003eDimensions measure 190 mm depth, 118 mm height, and 34 mm width. Net weight totals 0.295 kg.\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cb\u003e\u003cspan style=\"color:#003366;\"\u003eInstallation Guide\u003c\/span\u003e\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMount the \u003cb\u003e\u003cspan style=\"color:#003366;\"\u003eDO05\u003c\/span\u003e\u003c\/b\u003e module securely onto standard industrial rails.\u003c\/li\u003e\n  \u003cli\u003eEnsure correct physical orientation for horizontal row or vertical column layouts.\u003c\/li\u003e\n  \u003cli\u003eConnect field wiring directly to the mandatory \u003cb\u003e\u003cspan style=\"color:#003366;\"\u003exBS02-EPD\u003c\/span\u003e\u003c\/b\u003e terminal base.\u003c\/li\u003e\n  \u003cli\u003eVerify jumper positions for normally open or normally closed contact configurations prior to power-up.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003e\u003cspan style=\"color:#003366;\"\u003eCommissioning \u0026amp; Maintenance Ease\u003c\/span\u003e\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFront-panel LED indicators display real-time channel output status for fast diagnostics.\u003c\/li\u003e\n  \u003cli\u003ePlug-and-play base mounting structure simplifies hardware replacement during scheduled maintenance.\u003c\/li\u003e\n  \u003cli\u003eStandardized connection layouts reduce wiring errors during initial system commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003e\u003cspan style=\"color:#003366;\"\u003eCompatibility Statement\u003c\/span\u003e\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCompatible exclusively with the \u003cb\u003e\u003cspan style=\"color:#003366;\"\u003eABB Symphony Plus\u003c\/span\u003e\u003c\/b\u003e control architecture.\u003c\/li\u003e\n  \u003cli\u003eRequires the dedicated \u003cb\u003e\u003cspan style=\"color:#003366;\"\u003exBS02-EPD\u003c\/span\u003e\u003c\/b\u003e terminal base for proper electrical termination.\u003c\/li\u003e\n  \u003cli\u003eNote: This module does not support HART communication protocols, sequence of events (SOE) recording, or hardware redundancy.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003e\u003cspan style=\"color:#003366;\"\u003eCertification Information\u003c\/span\u003e\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eManufactured in compliance with stringent industrial quality standards.\u003c\/li\u003e\n  \u003cli\u003eReliability metrics validated through military handbook calculation methodologies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003e\u003cspan style=\"color:#003366;\"\u003ePackage Contents\u003c\/span\u003e\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOne \u003cb\u003e\u003cspan style=\"color:#003366;\"\u003eABB DO05\u003c\/span\u003e\u003c\/b\u003e digital output module (\u003cb\u003e\u003cspan style=\"color:#003366;\"\u003e8VZZ000167H1\u003c\/span\u003e\u003c\/b\u003e).\u003c\/li\u003e\n  \u003cli\u003eFactory technical instruction sheet.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003e\u003cspan style=\"color:#003366;\"\u003eFrequently Asked Questions (FAQ)\u003c\/span\u003e\u003c\/b\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cb\u003eQ: Which terminal base is required for the DO05 module?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Technicians must install this module onto the \u003cb\u003e\u003cspan style=\"color:#003366;\"\u003exBS02-EPD\u003c\/span\u003e\u003c\/b\u003e terminal base to ensure correct mechanical mounting and signal routing.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eQ: Can this module operate inductive DC loads safely?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, provided that users apply appropriate external freewheeling diodes or suppression circuits to protect relay contacts against inductive kickback.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eQ: How do I select between normally open and normally closed modes?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Users configure the operational mode by adjusting the onboard hardware jumpers located on the module circuit assembly before field deployment.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cb\u003e\u003cspan style=\"color:#003366;\"\u003eBuying Guidance\u003c\/span\u003e\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eWhen expanding your \u003cb\u003e\u003cspan style=\"color:#003366;\"\u003eABB Symphony Plus\u003c\/span\u003e\u003c\/b\u003e control system, verify your cabinet space requirements and ensure your existing system architecture utilizes the \u003cb\u003e\u003cspan style=\"color:#003366;\"\u003exBS02-EPD\u003c\/span\u003e\u003c\/b\u003e base. Contact our sales engineering team today to request a formal quotation or confirm project delivery timelines for part number \u003cb\u003e\u003cspan style=\"color:#003366;\"\u003e8VZZ000167H1\u003c\/span\u003e\u003c\/b\u003e.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":68089031426230,"sku":"8VZZ000167H1","price":205.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/8VZZ000167H1-1.jpg?v=1794971165","url":"https:\/\/www.plcsparehub.com\/products\/abb-do05-symphony-plus-16-channel-relay-output-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}