{"product_id":"abb-ci867ak01-3bse043660r1-modbus-tcp-ac-800m-module","title":"ABB CI867AK01 3BSE043660R1 Modbus TCP AC 800M Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #004085;\"\u003eABB CI867AK01\u003c\/strong\u003e (\u003cstrong style=\"color: #004085;\"\u003e3BSE043660R1\u003c\/strong\u003e) provides Modbus TCP communication for \u003cstrong style=\"color: #004085;\"\u003eAC 800M\u003c\/strong\u003e automation networks.\u003c\/p\u003e\n\u003cp\u003eThis complete hardware package includes the \u003cstrong style=\"color: #004085;\"\u003eCI867A\u003c\/strong\u003e communication interface and the \u003cstrong style=\"color: #004085;\"\u003eTP867\u003c\/strong\u003e baseplate.\u003c\/p\u003e\n\u003cp\u003eIt establishes reliable connections between process controllers and external Ethernet devices.\u003c\/p\u003e\n\u003cp\u003eEngineers utilize this unit for high-speed master and slave data messaging.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong style=\"color: #004085;\"\u003eABB\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel \/ Kit Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong style=\"color: #004085;\"\u003eCI867AK01\u003c\/strong\u003e \/ \u003cstrong style=\"color: #004085;\"\u003e3BSE043660R1\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong style=\"color: #004085;\"\u003e3BSE092689R1\u003c\/strong\u003e (\u003cstrong style=\"color: #004085;\"\u003eCI867A\u003c\/strong\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong style=\"color: #004085;\"\u003eSystem 800xA\u003c\/strong\u003e \/ \u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/ac-800m\"\u003e\u003cstrong style=\"color: #004085;\"\u003eAC 800M\u003c\/strong\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus TCP (OSI Layer 7 Application Messaging)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 RJ-45 Port (100 Mbit\/s Full Duplex)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaster \/ Slave Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 8 Masters and 70 Slaves per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCEX Bus Limit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaximum 12 modules per controller station\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to +55 °C (+32 to +131 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 °C (-40 to +158 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG3 Conformal Coating (ISA 71.04), IP20 Ingress Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 2000 meters (IEC\/EN 61131-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Certifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, UL 61010-1, UL 60079-15 Class 1 Zone 2, DNV-GL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Compatibility \u0026amp; Software Support\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRequires \u003cstrong style=\"color: #004085;\"\u003eSystem 800xA\u003c\/strong\u003e software version 6.0.3.3, 6.1.1, or subsequent releases.\u003c\/li\u003e\n\u003cli\u003eIntegrates directly with standard \u003cstrong style=\"color: #004085;\"\u003eAC 800M\u003c\/strong\u003e controllers.\u003c\/li\u003e\n\u003cli\u003eFully compatible with High Integrity (\u003cstrong style=\"color: #004085;\"\u003eHI\u003c\/strong\u003e) controller configurations.\u003c\/li\u003e\n\u003cli\u003eSupports paired redundant hardware setups for high-availability applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide \u0026amp; Commissioning\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the \u003cstrong style=\"color: #004085;\"\u003eTP867\u003c\/strong\u003e baseplate onto the standard CEX-Bus rail.\u003c\/li\u003e\n\u003cli\u003eConnect an 8-pin RJ-45 Ethernet cable to your network switch.\u003c\/li\u003e\n\u003cli\u003eThe internal converter draws regulated power from the +24V CEX supply.\u003c\/li\u003e\n\u003cli\u003eHot-swap capability permits module replacement without stopping controller execution.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagnostics \u0026amp; Operational Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMonitors Ethernet frame transmission traffic continuously.\u003c\/li\u003e\n\u003cli\u003eProvides front-panel status indicators for instant optical verification.\u003c\/li\u003e\n\u003cli\u003eDetects communication timeouts and illegal function code requests automatically.\u003c\/li\u003e\n\u003cli\u003eReports hardware fault events directly to the system diagnostic log.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Application Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLinking variable speed drives to primary process control loops.\u003c\/li\u003e\n\u003cli\u003eInterfacing intelligent power meters and protection relays to DCS system.\u003c\/li\u003e\n\u003cli\u003eConnecting third-party PLCs into the centralized supervisory control network.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eIn power station retrofits, engineers often integrate sub-station power monitors into \u003cstrong style=\"color: #004085;\"\u003eSystem 800xA\u003c\/strong\u003e controllers.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #004085;\"\u003eABB CI867AK01\u003c\/strong\u003e processes complex Modbus registers without increasing controller CPU load.\u003c\/p\u003e\n\u003cp\u003eDeploying dual interface modules eliminates single points of failure across critical Ethernet networks.\u003c\/p\u003e\n\u003cp\u003eConformal G3 coating ensures long-term operational stability inside high-vibration motor control rooms.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSelection \u0026amp; Procurement Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eChoose the \u003cstrong style=\"color: #004085;\"\u003eCI867A\u003c\/strong\u003e interface when high-speed 100 Mbps throughput is essential.\u003c\/li\u003e\n\u003cli\u003eVerify system software levels before upgrading older communication modules.\u003c\/li\u003e\n\u003cli\u003eOrder two units per controller station if your process demands module redundancy.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage List \u0026amp; Delivery Terms\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIncluded Items: One \u003cstrong style=\"color: #004085;\"\u003eCI867A\u003c\/strong\u003e communication module and one \u003cstrong style=\"color: #004085;\"\u003eTP867\u003c\/strong\u003e baseplate.\u003c\/li\u003e\n\u003cli\u003eWarranty Term: Complete 12-month factory coverage.\u003c\/li\u003e\n\u003cli\u003eDispatch Speed: Ships within 24 to 48 hours.\u003c\/li\u003e\n\u003cli\u003eExpress Logistics: Delivered via FedEx, UPS, or DHL.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What software release is mandatory for this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: The module requires \u003cstrong style=\"color: #004085;\"\u003eSystem 800xA\u003c\/strong\u003e version 6.0.3.3, 6.1.1, or higher.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can engineers replace this module while system power remains on?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: Yes, the unit supports complete hot-swap functionality during system operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: How many slave devices can one module manage?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: A single interface supports up to 70 slave units and 8 master units.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: How does this model differ from legacy interface units?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA4: This updated model features one dedicated 100 Mbps full-duplex Ethernet port.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45370321961142,"sku":"CI867AK01","price":203.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/CI867AK01.jpg?v=1787196832","url":"https:\/\/www.plcsparehub.com\/products\/abb-ci867ak01-3bse043660r1-modbus-tcp-ac-800m-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}