{"product_id":"abb-bailey-imdsi02-infi-90-plc-digital-input-interface-module","title":"ABB Bailey IMDSI02 Infi 90 PLC Digital Input Interface Module","description":"\u003ch3\u003e\u003cb\u003eProduct Overview | ABB Bailey IMDSI02\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #1565c0;\"\u003eABB Bailey IMDSI02\u003c\/strong\u003e is a 16-channel Digital Slave Input Module for the \u003cstrong style=\"color: #1565c0;\"\u003eInfi 90 Process Management System\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt acquires discrete field signals and transfers their states to the system for control and monitoring. Typical signal sources include contact closures, switches, and solenoid-operated devices.\u003c\/p\u003e\n\u003cp\u003eThe module supports three nominal input voltage classes: 24 VDC, 125 VDC, and 120 VAC. Individual input jumpers configure the voltage selection and response characteristics.\u003c\/p\u003e\n\u003cp\u003eDC channels offer fast and slow response settings. These settings help engineers manage contact bounce and field-device switching behavior. Front-panel LEDs provide visual channel status during commissioning and maintenance.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eIMDSI02\u003c\/strong\u003e occupies one slot in a standard Infi 90 Module Mounting Unit. Its modular design supports installation and removal without shutting down the entire system.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eTechnical Specifications | Electrical and Functional Data\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB Bailey\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong style=\"color: #1565c0;\"\u003eIMDSI02\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInfi 90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital Slave Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunctional Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital Input \/ Discrete Signal Acquisition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 independent digital inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Input Voltages\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC, 125 VDC, 120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24 VDC Tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e125 VDC Tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e120 VAC Tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Input Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.5 mA at 24 VDC; 5.0 mA at 125 VDC; 7.0 mA at 120 VAC, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC Fast Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC Slow Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLogic Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 VDC ±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Logic Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Logic Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e79 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput-to-Logic Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 V RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput-to-Input Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 V RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOne slot in a standard Infi 90 Module Mounting Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCSA, ordinary non-hazardous locations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cb\u003eInput Signal Thresholds | Switching Characteristics\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIMDSI02\u003c\/strong\u003e uses defined ON and OFF voltage thresholds. These values help engineers evaluate field signal compatibility.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Turn-On Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Turn-Off Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003ctd\u003e21.4 VDC\u003c\/td\u003e\n\u003ctd\u003e12 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e125 VDC\u003c\/td\u003e\n\u003ctd\u003e95.0 VDC\u003c\/td\u003e\n\u003ctd\u003e60 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e120 VAC\u003c\/td\u003e\n\u003ctd\u003e85.0 VAC\u003c\/td\u003e\n\u003ctd\u003e42 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Input Current at Minimum Turn-On Voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e24 VDC: 3 mA at 21.4 VDC.\u003c\/li\u003e\n\u003cli\u003e125 VDC: 3 mA at 95.0 VDC.\u003c\/li\u003e\n\u003cli\u003e120 VAC: 5 mA at 85.0 VAC, 60 Hz.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum OFF-State Leakage Current\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e24 VDC: 10 μA at input voltages up to 12 VDC.\u003c\/li\u003e\n\u003cli\u003e125 VDC: 10 μA at input voltages up to 60 VDC.\u003c\/li\u003e\n\u003cli\u003e120 VAC: 1.6 mA at input voltages up to 42 VAC, 60 Hz.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe voltage difference between ON and OFF thresholds provides switching hysteresis. Engineers should verify field-device output levels against both thresholds.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eResponse Configuration | Fast and Slow DC Inputs\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module provides two selectable DC response modes. Individual input jumpers determine the configured response behavior.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse Setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFast\u003c\/td\u003e\n\u003ctd\u003e1.5 ms\u003c\/td\u003e\n\u003ctd\u003eFaster discrete signal detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlow\u003c\/td\u003e\n\u003ctd\u003e17 ms\u003c\/td\u003e\n\u003ctd\u003eMechanical contacts with longer bounce periods\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eEngineering Selection Guidelines\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSelect fast response for signals requiring quicker state recognition.\u003c\/li\u003e\n\u003cli\u003eSelect slow response when field contacts produce mechanical bounce.\u003c\/li\u003e\n\u003cli\u003eCheck the switching characteristics of connected sensors and relays.\u003c\/li\u003e\n\u003cli\u003eMatch response settings with the required control sequence.\u003c\/li\u003e\n\u003cli\u003eVerify every input jumper before returning the system to operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eResponse time affects signal recognition. It does not define the complete system scan time or control-loop execution time.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eIsolation and Communication Architecture\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #1565c0;\"\u003eIMDSI02\u003c\/strong\u003e uses a passive contact input interface. A Multi-Function Processor or Logic Master Module reads its input states through the slave expander bus.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Structure\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eField devices provide discrete electrical signals.\u003c\/li\u003e\n\u003cli\u003eThe input circuitry detects the corresponding signal states.\u003c\/li\u003e\n\u003cli\u003eFront-panel LEDs indicate individual input conditions.\u003c\/li\u003e\n\u003cli\u003eThe slave expander bus carries input information to the master module.\u003c\/li\u003e\n\u003cli\u003eThe master module processes the acquired information.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput-to-logic circuitry isolation: 300 V RMS.\u003c\/li\u003e\n\u003cli\u003eInput-to-input isolation: 300 V RMS.\u003c\/li\u003e\n\u003cli\u003eCSA approval covers the specified 300 V isolation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis isolation helps separate field signal circuits from logic circuitry. It also reduces unwanted electrical interaction between input circuits.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eTypical Industrial Applications\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcess Monitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCollects discrete status signals from industrial field equipment.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMonitors contactor feedback and auxiliary contact conditions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eValve Control Systems\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAcquires limit-switch and solenoid-related status signals.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEquipment Interlocking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransfers switch and contact states to control logic.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower System Monitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMonitors compatible DC and AC discrete signals.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndustrial Alarm Systems\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCollects equipment status and process alarm inputs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cb\u003eInstallation Guide | Mounting and Configuration\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module occupies one slot in a standard Infi 90 Module Mounting Unit.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eConfirm the system uses a compatible Infi 90 mounting unit.\u003c\/li\u003e\n\u003cli\u003eCheck the module identification and physical condition.\u003c\/li\u003e\n\u003cli\u003eReview the field signal voltage for each input.\u003c\/li\u003e\n\u003cli\u003eSet individual voltage jumpers according to the application.\u003c\/li\u003e\n\u003cli\u003eSelect fast or slow response for applicable DC inputs.\u003c\/li\u003e\n\u003cli\u003eVerify all jumper positions against the wiring documentation.\u003c\/li\u003e\n\u003cli\u003eInstall the module in the designated mounting slot.\u003c\/li\u003e\n\u003cli\u003eConnect the field signal wiring according to the system drawings.\u003c\/li\u003e\n\u003cli\u003eRestore or maintain system operation according to approved procedures.\u003c\/li\u003e\n\u003cli\u003eCheck front-panel LEDs and confirm input status.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swapping Capability:\u003c\/strong\u003e The module supports installation and removal without powering down the system. Follow the approved site maintenance procedure before handling any module.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eCommissioning, Diagnostics and Maintenance\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe front-panel LED indicators simplify channel-level inspection. Engineers can compare physical field conditions with the displayed input states.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRecommended Commissioning Checks\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the input voltage class for every channel.\u003c\/li\u003e\n\u003cli\u003eMeasure field voltage under actual operating conditions.\u003c\/li\u003e\n\u003cli\u003eCheck ON and OFF switching thresholds.\u003c\/li\u003e\n\u003cli\u003eConfirm the selected DC response mode.\u003c\/li\u003e\n\u003cli\u003eCompare LED indications with field-device states.\u003c\/li\u003e\n\u003cli\u003eVerify communication through the slave expander bus.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePreventive Maintenance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInspect module seating and mounting contacts.\u003c\/li\u003e\n\u003cli\u003eCheck field wiring for loose or damaged connections.\u003c\/li\u003e\n\u003cli\u003eReview jumper positions after wiring modifications.\u003c\/li\u003e\n\u003cli\u003eInvestigate unexpected LED status changes.\u003c\/li\u003e\n\u003cli\u003eCheck for excessive electrical noise or unstable field supplies.\u003c\/li\u003e\n\u003cli\u003eRecord input assignments and configuration changes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eCompatibility and System Integration\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB Bailey Infi 90 Process Management System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Family\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInfi 90 Digital Slave Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaster Modules\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMulti-Function Processor or Logic Master Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSlave expander bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 digital input signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Signals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC, 125 VDC, and 120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard Infi 90 Module Mounting Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eCompatibility Note:\u003c\/strong\u003e Verify the system generation, mounting unit, master module, and expander bus configuration before ordering. Also confirm the required voltage and response settings for every field channel.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eEnvironmental Specifications and Certifications\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 70°C (32°F to 158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–95% up to 55°C, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHigh-Temperature Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–45% at 70°C, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAtmospheric Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSea level to 3 km altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAir Quality\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-corrosive atmosphere\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 V RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCSA certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApproved Location\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOrdinary, non-hazardous locations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe CSA certification applies to process control equipment in ordinary locations. Do not assume hazardous-area approval without separate documentation.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003ePackaging and Commercial Information\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 × ABB Bailey IMDSI02 Digital Slave Input Module.\u003c\/li\u003e\n\u003cli\u003eProduct identification and model verification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondition:\u003c\/strong\u003e New \u0026amp; Original in Factory Packing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e Factory Warranty: 12 Months.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping:\u003c\/strong\u003e FedEx, UPS, and DHL available.\u003c\/li\u003e\n\u003cli\u003eAdditional accessories: Confirm separately according to order requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eFrequently Asked Questions | Engineering and Selection\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can the IMDSI02 monitor AC and DC signals within the same installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The module supports 24 VDC, 125 VDC, and 120 VAC input classes. Engineers must configure each input using the appropriate voltage jumper. Always verify the channel wiring and jumper arrangement before energizing the circuit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: How should engineers select the correct input voltage configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStart with the field device's nominal output voltage. Then check its actual operating range against the module's ON and OFF thresholds. Consider supply variation and voltage drop across long cables. Select the corresponding input configuration only after confirming these values.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What should engineers investigate when an input LED remains ON after the field contact opens?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMeasure the voltage at the module input terminal. Compare the reading with the specified maximum OFF threshold. Check leakage current from electronic sensors, relay contacts, and connected suppression components. Also inspect wiring for unintended voltage coupling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Does the hot-swap feature eliminate all electrical maintenance precautions?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Hot-swapping allows module replacement without shutting down the entire system. However, field circuits may still carry hazardous voltage. Follow site isolation procedures and verify the electrical safety requirements before removing or installing the module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What details should buyers provide when sourcing an IMDSI02 replacement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eProvide the complete model number and existing system configuration. Include the required input voltage classes and DC response settings. Confirm the mounting unit and master module compatibility. These details help prevent incorrect selection and reduce commissioning delays.\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IMDSO04.png?v=1795419956\" alt=\"\"\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":68128837992630,"sku":"IMDSI02","price":113.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IMDSI02-1.jpg?v=1795420009","url":"https:\/\/www.plcsparehub.com\/products\/abb-bailey-imdsi02-infi-90-plc-digital-input-interface-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}