{"product_id":"abb-apbu-44c-24vdc-acs800-ddcs-communication-module","title":"ABB APBU-44C 24VDC ACS800 DDCS Communication Module","description":"\u003ch3\u003e\u003cb\u003eProduct Overview\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB APBU-44C\u003c\/strong\u003e is a four-channel branching unit for the \u003cstrong\u003eDDCS (Distributed Drives Communication System)\u003c\/strong\u003e. It distributes optical communication links between compatible ABB drive components.\u003c\/p\u003e\n\u003cp\u003eThe unit supports fiber optic connections between drive modules, RDCU control units, PCs, and external trigger interfaces. It provides a practical connection point for coordinating communication across a distributed drive system.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eAPBU-44C\u003c\/strong\u003e supports up to \u003cstrong\u003e4 connected modules\u003c\/strong\u003e. Its interface design includes multiple optical ports and a redundant 24 VDC power input.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable style=\"width: 99.9421%; height: 490px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 21.9077%; height: 19.6px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.1794%; height: 19.6px;\"\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 21.9077%; height: 19.6px;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.1794%; height: 19.6px;\"\u003e\u003cstrong\u003eAPBU-44C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 21.9077%; height: 19.6px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.1794%; height: 19.6px;\"\u003e\u003cstrong\u003e64688391C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 21.9077%; height: 19.6px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.1794%; height: 19.6px;\"\u003eDDCS Optical Fiber Branching Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 21.9077%; height: 39.2px;\"\u003e\u003cstrong\u003eCommunication System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.1794%; height: 39.2px;\"\u003eDDCS – Distributed Drives Communication System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 21.9077%; height: 19.6px;\"\u003e\u003cstrong\u003eOptical Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.1794%; height: 19.6px;\"\u003e4 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 21.9077%; height: 39.2px;\"\u003e\u003cstrong\u003eOptical Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.1794%; height: 39.2px;\"\u003eV1–V36 port designation range; verify individual port assignments against the unit documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 21.9077%; height: 19.6px;\"\u003e\u003cstrong\u003eModule Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.1794%; height: 19.6px;\"\u003eUp to 4 connected modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 21.9077%; height: 19.6px;\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.1794%; height: 19.6px;\"\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 21.9077%; height: 19.6px;\"\u003e\u003cstrong\u003ePower Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.1794%; height: 19.6px;\"\u003eX1 redundant 24 VDC supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 21.9077%; height: 39.2px;\"\u003e\u003cstrong\u003eMaximum Input Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.1794%; height: 39.2px;\"\u003e200–400 mA, as supplied; confirm the applicable configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 21.9077%; height: 19.6px;\"\u003e\u003cstrong\u003eNode Address Setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.1794%; height: 19.6px;\"\u003eS1–S2 rotary switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 21.9077%; height: 19.6px;\"\u003e\u003cstrong\u003eConfiguration Switch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.1794%; height: 19.6px;\"\u003eS3 DIP switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 21.9077%; height: 19.6px;\"\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.1794%; height: 19.6px;\"\u003eDIN rail mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 21.9077%; height: 39.2px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.1794%; height: 39.2px;\"\u003e0 to +50 °C, according to the supplied APBU-44C-specific information\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 21.9077%; height: 19.6px;\"\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.1794%; height: 19.6px;\"\u003e-40 to +70 °C, ACS800 drive-level reference; confirm APBU-specific limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 21.9077%; height: 19.6px;\"\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.1794%; height: 19.6px;\"\u003e5% to 95%, non-condensing; ACS800 drive-level reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 21.9077%; height: 19.6px;\"\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.1794%; height: 19.6px;\"\u003eIP20, internal installation context\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Note:\u003c\/strong\u003e The supplied 200–400 mA current range requires configuration-specific confirmation. Do not treat it as a guaranteed continuous consumption value.\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSwitch Configuration and Installation\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAPBU-44C\u003c\/strong\u003e uses rotary and DIP switches for communication configuration. Confirm the required settings before connecting the unit to an operating system.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eS1–S2:\u003c\/strong\u003e Rotary switches set the DDCS node address.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eS3:\u003c\/strong\u003e DIP switch configures optical power and memory backup functions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eV11:\u003c\/strong\u003e The supplied information associates this setting with optical power configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCR2032:\u003c\/strong\u003e Provides memory backup when the supported battery function is used.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eS3 Position 6:\u003c\/strong\u003e Set to ON when using the specified memory backup battery function.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCheck the exact switch positions against the applicable APBU-44C manual. Incorrect settings can interrupt communication or affect memory backup operation.\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":68105154330806,"sku":"APBU-44C","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/APBU-44C-3.jpg?v=1795074573","url":"https:\/\/www.plcsparehub.com\/products\/abb-apbu-44c-24vdc-acs800-ddcs-communication-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}