{"product_id":"abb-ai830-s800-8-channel-rtd-analog-input-module-specs-quote","title":"ABB AI830 S800 8-Channel RTD Analog Input Module Specs \u0026 Quote","description":"\u003ch3\u003eProduct Introduction\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB AI830\u003c\/strong\u003e and \u003cstrong\u003eAI830A\u003c\/strong\u003e belong to the robust \u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/s800-i-o\"\u003e\u003cstrong\u003eS800 I\/O\u003c\/strong\u003e\u003c\/a\u003e series. These units function as high-performance \u003cstrong\u003eAnalog Input Modules\u003c\/strong\u003e designed specifically for precise temperature measurement. Each module features \u003cstrong\u003e8 independent channels\u003c\/strong\u003e supporting \u003cstrong\u003e3-wire connections\u003c\/strong\u003e for industrial RTD and resistive elements. Engineers rely on these devices to ensure isolated, accurate data acquisition in demanding plant environments.\u003c\/p\u003e\n\u003cp\u003eGlobal PLC Spare HUB's Insight: In high-noise industrial environments, deploying the \u003cstrong\u003eAI830\u003c\/strong\u003e module with properly shielded three-wire RTD cables significantly reduces lead-resistance errors. Experienced technicians always verify that the \u003cstrong\u003eMainsFreq\u003c\/strong\u003e parameter matches the local electrical grid to activate the internal notch filter, eliminating disruptive 50 Hz or 60 Hz hum before it reaches the control system.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTechnical Parameter\u003c\/th\u003e\n\u003cth\u003eSpecification Detail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand \u0026amp; Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eABB AI830\u003c\/strong\u003e \/ \u003cstrong\u003eAI830A\u003c\/strong\u003e (S800 Series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Input Module\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e8 channels\u003c\/strong\u003e (Individually configurable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePt100, Cu10, Ni100, Ni120, and resistive potentiometers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e14 Bit resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinearity \u0026amp; Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInternal linearization to Centigrade or Fahrenheit; error dependent on field cable resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUpdate Cycle Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 + 95 × number of active channels ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterference Immunity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCMRR \u0026gt;120 dB at 10Ω load; NMRR \u0026gt;60 dB (50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to +55°C (+32°F to +131°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 protection class; ISA-S71.04 G3 corrosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation \u0026amp; Compatibility Guide\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe \u003cstrong\u003eAI830\u003c\/strong\u003e mounts seamlessly onto modular Termination Units (\u003cstrong\u003eMTUs\u003c\/strong\u003e).\u003c\/li\u003e\n\u003cli\u003eCompatible \u003cstrong\u003eMTUs\u003c\/strong\u003e include \u003cstrong\u003eTU810\u003c\/strong\u003e, \u003cstrong\u003eTU812\u003c\/strong\u003e, \u003cstrong\u003eTU814\u003c\/strong\u003e, \u003cstrong\u003eTU830\u003c\/strong\u003e, and \u003cstrong\u003eTU833\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eVerify that the mechanical \u003cstrong\u003eKeying code AF\u003c\/strong\u003e aligns correctly before insertion.\u003c\/li\u003e\n\u003cli\u003eEnsure vertical mounting limits ambient temperatures to 40°C in compact setups.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDiagnostics \u0026amp; Error Handling\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFront panel LEDs clearly indicate \u003cstrong\u003eF\u003c\/strong\u003eault, \u003cstrong\u003eR\u003c\/strong\u003eun, and \u003cstrong\u003eW\u003c\/strong\u003earning states.\u003c\/li\u003e\n\u003cli\u003eThe system continuously monitors for open-circuit and short-circuit faults.\u003c\/li\u003e\n\u003cli\u003eInternal power supply supervision prevents unflagged reading corruptions.\u003c\/li\u003e\n\u003cli\u003eIndividual channel status indicators isolate faulty field wiring instantly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCertifications \u0026amp; Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Safety:\u003c\/strong\u003e EN 61010-1, UL 61010-1, and IEC standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Locations:\u003c\/strong\u003e C1 Div 2 cULus, C1 Zone 2 cULus, and ATEX Zone 2 approvals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine Standards:\u003c\/strong\u003e Certified by ABS, BV, DNV, and LR for harsh marine environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirectives:\u003c\/strong\u003e Fully compliant with CE, RoHS, and WEEE regulations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLogistics, Package \u0026amp; Warranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Contents:\u003c\/strong\u003e One \u003cstrong\u003eABB AI830\u003c\/strong\u003e or \u003cstrong\u003eAI830A\u003c\/strong\u003e module with plug-in connectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Partners:\u003c\/strong\u003e Fast and reliable dispatch via \u003cstrong\u003eFedEx\u003c\/strong\u003e, \u003cstrong\u003eUPS\u003c\/strong\u003e, and \u003cstrong\u003eDHL\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFulfillment Speed:\u003c\/strong\u003e Orders process and ship within \u003cstrong\u003e24-48 hours\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty Terms:\u003c\/strong\u003e Backed by a standard \u003cstrong\u003e12-month warranty\u003c\/strong\u003e from Global PLC Spare HUB.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTypical Application Scenarios\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower generation turbine bearing temperature monitoring.\u003c\/li\u003e\n\u003cli\u003eChemical reactor core thermal tracking via Pt100 sensors.\u003c\/li\u003e\n\u003cli\u003eHVAC centralized monitoring networks requiring high channel density.\u003c\/li\u003e\n\u003cli\u003eOil and gas pipeline temperature safety interlocks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eQ: Can I mix different RTD sensor types across the 8 channels of the \u003cstrong\u003eAI830\u003c\/strong\u003e?\u003c\/h4\u003e\n\u003cp\u003eYes, every channel on the \u003cstrong\u003eAI830\u003c\/strong\u003e and \u003cstrong\u003eAI830A\u003c\/strong\u003e can be individually configured for Pt100, Cu10, Ni100, Ni120, or raw resistance.\u003c\/p\u003e\n\u003ch4\u003eQ: What causes a channel error on the \u003cstrong\u003eAI830A\u003c\/strong\u003e module during startup?\u003c\/h4\u003e\n\u003cp\u003eChannel errors typically stem from unconfigured open channels, broken sensor wires, or field cable resistance exceeding normal tolerances.\u003c\/p\u003e\n\u003ch4\u003eQ: How do I select the right MTU for the \u003cstrong\u003eAI830\u003c\/strong\u003e?\u003c\/h4\u003e\n\u003cp\u003eChoose a compatible base unit like the \u003cstrong\u003eTU810V1\u003c\/strong\u003e or \u003cstrong\u003eTU830\u003c\/strong\u003e, making sure the physical keying matches the module's \u003cstrong\u003eAF\u003c\/strong\u003e code.\u003c\/p\u003e\n\u003ch4\u003eQ: What is the best buying practice for replacing an older \u003cstrong\u003eAI830\u003c\/strong\u003e unit?\u003c\/h4\u003e\n\u003cp\u003eAlways confirm your exact hardware revision suffix and check your existing \u003cstrong\u003eMTU\u003c\/strong\u003e part number to guarantee immediate plug-and-play compatibility.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45013889122486,"sku":"AI830","price":286.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/AI830A.jpg?v=1787642500","url":"https:\/\/www.plcsparehub.com\/products\/abb-ai830-s800-8-channel-rtd-analog-input-module-specs-quote","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}