{"product_id":"aai143-h50-k4a00-yokogawa-centum-vp-16-channel-hart-analog-input-module","title":"AAI143-H50\/K4A00 Yokogawa CENTUM VP 16-Channel HART Analog Input Module","description":"\u003ch3\u003e\u003cstrong\u003eYokogawa AAI143-H50\/K4A00 | 16-Channel Isolated HART Analog Input Module\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #0066cc;\"\u003eYokogawa AAI143-H50\/K4A00\u003c\/span\u003e\u003c\/strong\u003e is a 16-channel analog input module designed to acquire 4–20 mA signals from industrial field transmitters. It supports HART digital communication and provides isolated input channels for compatible control system configurations.\u003c\/p\u003e\n\u003cp\u003eThis configuration combines the AAI143 analog input function with a KS Cable Interface Adapter. The adapter connects to the AEA4D Terminal Board and carries the model designation \u003cstrong\u003eATK4A-00\u003c\/strong\u003e. Engineers should verify the terminal board, cable arrangement, and host-system compatibility before installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication focus:\u003c\/strong\u003e Process signal acquisition, transmitter integration, and HART-enabled instrument maintenance in compatible Yokogawa control systems.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e01 | Product Identity and Configuration Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #0066cc;\"\u003eAAI143-H50\/K4A00\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAAI143\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 isolated channels, 4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Communication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHART supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface Adapter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKS Cable Interface Adapter, ATK4A-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Board Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAEA4D Terminal Board, subject to system verification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eModel code interpretation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAAI143:\u003c\/strong\u003e Identifies the analog input module model.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eH:\u003c\/strong\u003e Digital communication with the HART protocol.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5:\u003c\/strong\u003e Standard configuration without explosion protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0:\u003c\/strong\u003e Basic type.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eK4A00:\u003c\/strong\u003e KS Cable Interface Adapter configuration for connecting the AEA4D Terminal Board. The specified adapter model is ATK4A-00.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eConfirm the complete ordering code when selecting a replacement. Do not substitute a similar AAI143 variant without checking its communication features, protection type, and terminal interface.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e02 | Electrical Performance and Input Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Input Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16, isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Signal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAllowable Input Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±16 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Update Period\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Resistance, Power ON\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e270 Ω at 20 mA to 350 Ω at 4 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Resistance, Power OFF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 kΩ or greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput-to-System Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1500 V AC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature Drift\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±16 µA per 10°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.0 V or higher at 20 mA; 25.5 V or lower at 0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter Supply Current Limit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 mA at 5 V DC; 540 mA at 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eEngineering note:\u003c\/strong\u003e The 10 ms update period describes the specified data refresh interval. It does not establish the complete HART communication cycle time or the response time of the entire control loop.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e03 | HART Communication and Transmitter Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe HART-enabled \u003cstrong\u003e\u003cspan style=\"color: #0066cc;\"\u003eAAI143-H50\/K4A00\u003c\/span\u003e\u003c\/strong\u003e supports analog current acquisition and HART digital communication. This combination helps engineers integrate process measurements with supported smart field instruments.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog process values:\u003c\/strong\u003e Acquire 4–20 mA signals from compatible transmitters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital instrument access:\u003c\/strong\u003e Support HART communication when the host system, instrument, and configuration permit it.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransmitter wiring:\u003c\/strong\u003e Configure each channel for a 2-wire or 4-wire transmitter using the specified setting pin.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance support:\u003c\/strong\u003e Use available HART data for instrument checks when the control system provides the required functions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHART support does not guarantee that every instrument parameter will be accessible through every host system. Verify the instrument's HART revision, host capabilities, and engineering software configuration before commissioning.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e04 | Cable Interface and Terminal Board Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdapter:\u003c\/strong\u003e KS Cable Interface Adapter, model ATK4A-00.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal board:\u003c\/strong\u003e AEA4D Terminal Board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal connection options:\u003c\/strong\u003e Pressure clamp terminal, MIL connector cable, or dedicated KS1 cable, as applicable to the installed configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplacement check:\u003c\/strong\u003e Verify the actual cable type, connector arrangement, terminal board model, and wiring diagram.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDo not assume that a physically similar cable or terminal board provides electrical compatibility. Check the approved system drawings before reconnecting field wiring.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e05 | Compatible Equipment and Industrial Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThis module suits compatible Yokogawa control system installations that require isolated 4–20 mA input acquisition and HART communication. Verify the exact host system and hardware revision before ordering.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure measurement:\u003c\/strong\u003e Acquire signals from compatible pressure transmitters in process pipelines and vessels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature monitoring:\u003c\/strong\u003e Read 4–20 mA outputs from temperature transmitters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow measurement:\u003c\/strong\u003e Integrate compatible flow transmitters into process monitoring systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel measurement:\u003c\/strong\u003e Acquire level transmitter signals from storage tanks and process vessels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChemical processing:\u003c\/strong\u003e Support distributed process measurement where the installed control system permits this module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOil and gas:\u003c\/strong\u003e Support instrument signal acquisition in suitable process monitoring applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWater treatment:\u003c\/strong\u003e Integrate compatible field transmitters into plant monitoring and control architectures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe module is not a universal input card. Confirm the system series, I\/O configuration, terminal board, and applicable project requirements before installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e06 | Installation and Commissioning Procedure\u003c\/strong\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify the part number:\u003c\/strong\u003e Check AAI143-H50\/K4A00 against the approved equipment list.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the host system:\u003c\/strong\u003e Confirm the supported I\/O configuration and hardware revision.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect the interface:\u003c\/strong\u003e Verify the ATK4A-00 adapter, AEA4D terminal board, and applicable cable arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolate power:\u003c\/strong\u003e Follow site procedures before installing or disconnecting the module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck field wiring:\u003c\/strong\u003e Confirm polarity, grounding, shielding, and terminal assignments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSet transmitter type:\u003c\/strong\u003e Configure each channel for the specified 2-wire or 4-wire arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify the signal range:\u003c\/strong\u003e Confirm the configured input range and transmitter output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck HART access:\u003c\/strong\u003e Verify communication through the supported host system and engineering tools.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePerform a loop test:\u003c\/strong\u003e Compare known input current values with the displayed process values.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecord results:\u003c\/strong\u003e Document channel assignments, test values, alarms, and configuration changes.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eFollow the applicable Yokogawa installation manual for module insertion, removal, and energization. Do not assume that hot-swapping is supported.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e07 | Diagnostics and Field Troubleshooting\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eUse a channel-by-channel approach to distinguish instrument faults from wiring, configuration, and module-related problems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncorrect process value:\u003c\/strong\u003e Measure the loop current with an appropriate instrument. Compare the reading with the configured range and engineering units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultiple channels show errors:\u003c\/strong\u003e Inspect shared wiring, common power sources, terminal interfaces, and system configuration before replacing the module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHART communication fails:\u003c\/strong\u003e Confirm instrument support, loop wiring, host configuration, and HART communication settings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal instability:\u003c\/strong\u003e Check shielding, grounding, electrical noise sources, and loose terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature-related deviation:\u003c\/strong\u003e Review ambient conditions and compare observed errors with the specified temperature drift.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnexpected channel behavior:\u003c\/strong\u003e Confirm the 2-wire or 4-wire setting pin and verify the field instrument's wiring diagram.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eField example:\u003c\/strong\u003e A pressure reading remains incorrect after a transmitter replacement. Measure the loop current before changing the input module. If the current is correct but the displayed value is wrong, inspect channel scaling and engineering-unit settings first.\u003c\/p\u003e\n\u003cp\u003eThis example describes a general commissioning method. It does not represent a confirmed model-specific failure pattern.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e08 | Environmental and Certification Verification\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExplosion protection:\u003c\/strong\u003e The specified suffix identifies a version without explosion protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput isolation:\u003c\/strong\u003e The supplied specification lists 1500 V AC withstand voltage between input and system for one minute.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature and humidity limits:\u003c\/strong\u003e Confirm the applicable installation limits in the official hardware documentation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProject compliance:\u003c\/strong\u003e Check area classification, cabinet requirements, and instrument-loop documentation before installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNo additional certification details were supplied for this exact configuration. Request official documentation if the project requires specific approvals or formal compliance evidence.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e09 | Packaging, Warranty, and Delivery\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct:\u003c\/strong\u003e Yokogawa AAI143-H50\/K4A00 Analog Input Module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterface configuration:\u003c\/strong\u003e KS Cable Interface Adapter for the AEA4D Terminal Board, model ATK4A-00.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging:\u003c\/strong\u003e Protective packaging suitable for transport.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccessories:\u003c\/strong\u003e Confirm whether cables, terminal boards, and additional accessories are included in the quotation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12-month warranty, subject to the supplier's applicable terms and conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping methods:\u003c\/strong\u003e FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch estimate:\u003c\/strong\u003e Typically 24–48 hours after order confirmation, subject to stock and payment verification.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eContact the sales team to confirm availability, included items, warranty coverage, and the estimated delivery schedule before ordering.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e10 | Global PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWhen replacing an analog input module, engineers should verify more than the channel count and current range. The terminal interface and transmitter wiring configuration can determine whether an otherwise similar module fits the installed system.\u003c\/p\u003e\n\u003cp\u003eFor this configuration, the \u003cstrong\u003e\u003cspan style=\"color: #0066cc;\"\u003eK4A00\u003c\/span\u003e\u003c\/strong\u003e suffix identifies the KS Cable Interface Adapter arrangement for the AEA4D Terminal Board. Check the adapter model, cable type, and approved wiring drawings before disconnecting the existing installation.\u003c\/p\u003e\n\u003cp\u003eThe 16 isolated channels and HART support also help define the module's role in instrument integration. However, HART access depends on the host system and instrument configuration. Confirm the required digital functions during engineering review rather than assuming full device-management support.\u003c\/p\u003e\n\u003cp\u003eFor a replacement quotation, provide the complete model, installed terminal board, required quantity, and host-system information. These details reduce configuration uncertainty and help avoid delays during commissioning.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e11 | Frequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. How can engineers confirm the module's measurement accuracy during commissioning?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eApply known current values with a suitable loop calibrator. Compare the displayed values against the configured scaling and specified accuracy of ±16 µA. Record results across representative channels and investigate deviations before returning the loop to service.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. What should be checked when only one input channel reports an incorrect value?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInspect that channel's transmitter, wiring, setting pin, and scaling configuration first. Compare its behavior with a known-good channel when site procedures permit. Avoid replacing the entire module until field-side causes have been checked.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. Can a 4–20 mA transmitter use HART communication on this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module supports HART communication. Successful digital access also depends on the transmitter, host system, wiring, and engineering software. Verify these elements before planning device configuration or diagnostics through HART.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. What details matter most when selecting a replacement for an installed AAI143 module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMatch the complete model code, explosion-protection option, communication capability, terminal board, and cable interface. Also confirm the installed control system's hardware compatibility and the required transmitter wiring arrangement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e5. How should engineers investigate temperature-related signal deviations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck cabinet temperature, loop current, wiring integrity, and transmitter stability. The supplied specification lists a drift of ±16 µA per 10°C. Confirm the applicable measurement conditions and manufacturer guidance before attributing the deviation to the module.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eRequest a Quotation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eLooking for the \u003cstrong\u003e\u003cspan style=\"color: #0066cc;\"\u003eYokogawa AAI143-H50\/K4A00\u003c\/span\u003e\u003c\/strong\u003e isolated analog input module? Contact Global PLC Spare HUB for pricing, availability, and shipping options.\u003c\/p\u003e\n\u003cp\u003ePlease provide the required quantity, host-system model, and terminal board configuration. Our team can review the part identification and quotation requirements before order confirmation.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/AAI141_AAV141_AAV142_AAV144_AAI841_AAB841_AAV542_AAV544_AAI143_AAI543_AAT141.png?v=1792565856\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":67706857586870,"sku":"AAI143-H50\/K4A00","price":125.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/AAI143-H50-K4A00_d8b9917e-cab2-49c6-97a1-b1e8834adf1d.jpg?v=1792565797","url":"https:\/\/www.plcsparehub.com\/products\/aai143-h50-k4a00-yokogawa-centum-vp-16-channel-hart-analog-input-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}