{"product_id":"a06b-6096-h301-fanuc-alpha-series-3-axis-servo-amplifier-module-in-stock","title":"A06B-6096-H301 FANUC Alpha Series 3-Axis Servo Amplifier Module In Stock","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003eFANUC\u003c\/span\u003e\u003c\/b\u003e \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003eA06B-6096-H301\u003c\/span\u003e\u003c\/b\u003e is a high-precision 3-axis servo amplifier module engineered for the \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003eAlpha Series\u003c\/span\u003e\u003c\/b\u003e servo drive family. Operating across an input DC bus voltage range of 283V to 325V, it delivers smooth velocity and position control for L, M, and N motion axes. With an integrated thermal fan management system and built-in hardware protection circuits, the \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003eA06B-6096-H301\u003c\/span\u003e\u003c\/b\u003e provides continuous multi-axis motion synchronization in high-duty CNC machine tools.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eMulti-Axis Drive Architecture \u0026amp; Operational Ratings\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eTriple-Axis Control Matrix:\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eDrives L, M, and N axes independently from a single compact drive housing.\u003c\/li\u003e\n\u003cli\u003eDelivers a continuous output current rating of 3 Amps per axis channel.\u003c\/li\u003e\n\u003cli\u003eProvides a maximum 1.85 kW total power rating for multi-axis servo motors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePower Input and Voltage Dynamics:\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eAccepts rectified DC bus input voltage ranging between 283V DC and 325V DC.\u003c\/li\u003e\n\u003cli\u003eGenerates a maximum 3-phase AC output voltage of 230V AC to connected motor windings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMechanical and Thermal Enclosure Specs:\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eBuilt-in forced-air cooling fan dissipates heat during high-speed feed motion.\u003c\/li\u003e\n\u003cli\u003eWithstands mechanical vibration forces up to 5G across industrial machine frames.\u003c\/li\u003e\n\u003cli\u003eEngineered for stable operation at altitudes up to 1000 meters above sea level.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eTechnical Specifications Parameter Matrix\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #f2f2f2;\"\u003e\u003cb\u003eBrand \/ Manufacturer\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003eFANUC\u003c\/span\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #f2f2f2;\"\u003e\u003cb\u003ePart \/ Model Number\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003eA06B-6096-H301\u003c\/span\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #f2f2f2;\"\u003e\u003cb\u003eProduct Line Series\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003eA06B\u003c\/span\u003e\u003c\/b\u003e \/ \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003eAlpha Series\u003c\/span\u003e\u003c\/b\u003e Servo System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #f2f2f2;\"\u003e\u003cb\u003eModule Hardware Type\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e3-Axis Servo Amplifier Module (SVM3-12\/12\/12)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #f2f2f2;\"\u003e\u003cb\u003eAxis Support Count\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e3 Axes (L-Axis, M-Axis, N-Axis)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #f2f2f2;\"\u003e\u003cb\u003eNominal Output Current\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e3 Amps per axis (L \/ M \/ N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #f2f2f2;\"\u003e\u003cb\u003eInput DC Bus Voltage\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e283V DC to 325V DC (Fed from PSM unit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #f2f2f2;\"\u003e\u003cb\u003eMaximum Output Voltage\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e230V AC 3-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #f2f2f2;\"\u003e\u003cb\u003eMaximum Power Rating\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1.85 kW overall system output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #f2f2f2;\"\u003e\u003cb\u003eOperating Temperature Window\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to +40°C (32°F to 104°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #f2f2f2;\"\u003e\u003cb\u003eModule Weight\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e22.00 lbs (9.98 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #f2f2f2;\"\u003e\u003cb\u003eIntegrated Protections\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eOvercurrent, Overvoltage, Overheating, Short Circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cb\u003eSystem Compatibility \u0026amp; Machinery Deployment\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eHost CNC System Integration:\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eCommunicates via optical fiber interface with \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003eFANUC\u003c\/span\u003e\u003c\/b\u003e 16i, 18i, 21i, and 0i series controllers.\u003c\/li\u003e\n\u003cli\u003eReceives DC power rail connections directly from \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003eAlpha Series\u003c\/span\u003e\u003c\/b\u003e Power Supply Modules (PSM).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eTarget Machinery Applications:\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eMulti-axis CNC milling centers, vertical machining centers (VMC), and high-speed lathes.\u003c\/li\u003e\n\u003cli\u003eAutomated wire-cut EDM machines and robotic material-handling loader arms.\u003c\/li\u003e\n\u003cli\u003eAuxiliary axis positioning assemblies, rotary tables, and tool-changer mechanisms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eDiagnostic Capabilities \u0026amp; Alarm Protection\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eIntegrated Hardware Safety Features:\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eInstantaneous overcurrent detection trips power switches to protect motor windings.\u003c\/li\u003e\n\u003cli\u003eDC bus overvoltage monitoring halts operation during excessive regenerative braking.\u003c\/li\u003e\n\u003cli\u003eOnboard thermal sensors shut down drive logic during heatsink cooling breakdown.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eVisual Seven-Segment Alarm Status:\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eFront-panel status display outputs standard \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003eFANUC\u003c\/span\u003e\u003c\/b\u003e alarm codes (e.g., Alarm 8, 9, or A).\u003c\/li\u003e\n\u003cli\u003eAccelerates fault isolation between DC bus supply drops, motor insulation shorts, or feedback encoder loss.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eSupply Chain \u0026amp; Warranty Guarantees\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003ePackage Contents:\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eOne original \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003eFANUC\u003c\/span\u003e\u003c\/b\u003e \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003eA06B-6096-H301\u003c\/span\u003e\u003c\/b\u003e 3-axis servo amplifier module.\u003c\/li\u003e\n\u003cli\u003eAntistatic protective wrap sealed inside a heavy-duty cardboard shipping crate.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eWarranty Policy:\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eBacked by a full 12-month operational replacement warranty from date of shipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eExpress Shipping Logistics:\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eDispatched within 24 to 48 hours following order confirmation.\u003c\/li\u003e\n\u003cli\u003eGlobal express delivery supported by FedEx, UPS, or DHL.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eGlobal PLC Spare HUB's Insight\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eWhen servicing \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003eFANUC Alpha Series\u003c\/span\u003e\u003c\/b\u003e drive cabinets, site technicians frequently encounter IPM (Intelligent Power Module) overcurrent trips on multi-axis drives like the \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003eA06B-6096-H301\u003c\/span\u003e\u003c\/b\u003e. Because a single drive housing handles three distinct motor channels (L, M, and N), determining whether a fault originates inside the module or out in the machine bed requires a systematic insulation audit.\u003c\/p\u003e\n\u003cp\u003eDuring an emergency call at a precision machining facility, a CNC lathe threw a recurring alarm on the X\/Z auxiliary axis drive. Our field engineers disconnected the power output cables from terminals L, M, and N and measured phase-to-ground resistance on each motor cable using a 500V megohmmeter. The test revealed a breakdown in the M-axis motor power cable caused by coolant degradation. Replacing the harness preserved the \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003eA06B-6096-H301\u003c\/span\u003e\u003c\/b\u003e amplifier from internal transistor failure. We recommend verifying cabinet fan rotation airflow during preventative maintenance shutdowns, as dust buildup on the internal heatsink fins drastically accelerates thermal alarm trips.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eFrequently Asked Questions (FAQ)\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eQ: What is the primary function of the L, M, and N designations on the A06B-6096-H301 drive module?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: The L, M, and N labels designate the three independent servo motor output channels controlled by this single amplifier board.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ: Can the A06B-6096-H301 operate directly from a 3-phase 220V AC wall line?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. It requires a rectified 283V to 325V DC bus supply generated by an upstream \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003eFANUC\u003c\/span\u003e\u003c\/b\u003e Alpha Power Supply Module (PSM).\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ: What should I check first if the internal cooling fan on the A06B-6096-H301 stops rotating?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Inspect the fan connector for metal chips or debris. If power is present but the fan does not spin, replace the fan assembly immediately to avoid thermal trips.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ: Is it safe to swap out the A06B-6096-H301 drive while the main DC bus voltage LED is illuminated?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. Always wait for the power supply DC bus discharge indicator LED to extinguish completely (measuring under 50V DC) before removing any wiring.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ: How can I isolate whether an overcurrent alarm is caused by the A06B-6096-H301 or a shorted servo motor?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Disconnect output leads for L, M, and N channels. Power up the drive; if the overcurrent alarm persists with no cables attached, the amplifier module itself requires servicing.\u003c\/p\u003e","brand":"FANUC","offers":[{"title":"Default Title","offer_id":45013998108854,"sku":"A06B-6096-H301","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/A06B-6096-H301_79467491-33d1-4db7-a720-7a47212e1f2e.jpg?v=1788335193","url":"https:\/\/www.plcsparehub.com\/products\/a06b-6096-h301-fanuc-alpha-series-3-axis-servo-amplifier-module-in-stock","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}