{"product_id":"991-25-50-02-01-bently-nevada-991-series-thrust-position-transmitter-4-20ma","title":"991-25-50-02-01 Bently Nevada 991 Series Thrust Position Transmitter 4-20mA","description":"\u003ch3\u003e\u003cb\u003e01 | Instrument Overview\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #008000;\"\u003eBently Nevada 991-25-50-02-01\u003c\/strong\u003e is a 991 Series thrust position transmitter for axial machinery monitoring.\u003c\/p\u003e\n\u003cp\u003eIt converts displacement measurements from a compatible \u003cstrong\u003e3300 NSv Proximity Probe\u003c\/strong\u003e system into a standardized 4–20 mA output.\u003c\/p\u003e\n\u003cp\u003eThe transmitter accepts one non-contacting proximity probe and its extension cable. It provides a two-wire current-loop signal for connection to PLC, DCS, and machinery monitoring systems.\u003c\/p\u003e\n\u003cp\u003eThis configuration includes a 25-0-25 mil full-scale option, a 5.0 m system length, bulkhead screw mounting, and CSA Division 2 approval.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e02 | Technical Specification Matrix\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong style=\"color: #008000;\"\u003e991-25-50-02-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e991 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThrust Position Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturing Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMade in U.S.A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Direction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAxial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull-Scale Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25-0-25 mils\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.0 m (16.4 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBulkhead Screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOne 3300 NSv Non-Contacting Proximity Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Signal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4–20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo-Wire Current Loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+12 to +35 VDC at transmitter terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProx Output Linear Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.25 to 1.65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull-Scale Current-Loop Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.6-0-0.6 mm or 25-0-25 mils\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Loop Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±1.5% of specified full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Loop Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000 Ω, including cable, at 35 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Limiting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23 mA Typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-35°C to +85°C (-31°F to +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-51°C to +100°C (-60°F to +212°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.43 kg (0.9 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cb\u003e03 | Ordering Code Architecture\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eEach suffix identifies a specific measurement, installation, or approval configuration.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCode Segment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSelected Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration Meaning\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong style=\"color: #008000;\"\u003e991\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eThrust Position Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong style=\"color: #008000;\"\u003e-25\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFull-Scale Option\u003c\/td\u003e\n\u003ctd\u003e25-0-25 mils\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong style=\"color: #008000;\"\u003e-50\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem Length\u003c\/td\u003e\n\u003ctd\u003e5.0 m (16.4 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong style=\"color: #008000;\"\u003e-02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting Option\u003c\/td\u003e\n\u003ctd\u003eBulkhead Screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong style=\"color: #008000;\"\u003e-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency Approval\u003c\/td\u003e\n\u003ctd\u003eCSA Division 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Configuration Summary\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransmitter:\u003c\/strong\u003e 991 Thrust Position Transmitter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 25-0-25 mils.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Cable Length:\u003c\/strong\u003e 5.0 m.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Mounting:\u003c\/strong\u003e Bulkhead screws.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApproval Selection:\u003c\/strong\u003e CSA Division 2.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Interface:\u003c\/strong\u003e Two-wire 4–20 mA DC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003e04 | Measurement Principle and Signal Processing\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe transmitter receives displacement information from a compatible 3300 NSv proximity measurement system. It converts the measurement into a proportional current-loop signal.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Condition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Behavior\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Full-Scale Position\u003c\/td\u003e\n\u003ctd\u003e4 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMidpoint Reference\u003c\/td\u003e\n\u003ctd\u003e12 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Full-Scale Position\u003c\/td\u003e\n\u003ctd\u003e20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNot OK Condition\u003c\/td\u003e\n\u003ctd\u003eBelow 3.6 mA within 100 μs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Recovery\u003c\/td\u003e\n\u003ctd\u003eWithin 0.1 seconds after fault removal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Interpretation:\u003c\/strong\u003e The 4–20 mA output represents the configured axial measurement range. The receiving controller must use the correct engineering-unit scaling.\u003c\/p\u003e\n\u003cp\u003eThe transmitter also provides a Not OK\/Signal Defeat function. It drives the output below 3.6 mA when a Not OK condition occurs.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e05 | Electrical Performance and Loop Design\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply Requirements\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRequired input: +12 to +35 VDC.\u003c\/li\u003e\n\u003cli\u003eMeasure supply voltage at the transmitter terminals.\u003c\/li\u003e\n\u003cli\u003eMaintain sufficient voltage for the complete current-loop load.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent-Loop Characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput:\u003c\/strong\u003e 4–20 mA DC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e Typically within ±1.5% of specified full scale.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Loop Resistance:\u003c\/strong\u003e 1,000 Ω, including cable, at 35 VDC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Limiting:\u003c\/strong\u003e Approximately 23 mA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero Adjustment:\u003c\/strong\u003e External adjustment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpan Adjustment:\u003c\/strong\u003e External adjustment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustment Interaction:\u003c\/strong\u003e Zero and span adjustments operate independently.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy Test Reference:\u003c\/strong\u003e The specified accuracy uses the TEST signal input and voltage measurement across a 250 Ω loop resistance.\u003c\/p\u003e\n\u003cp\u003eWhen designing the receiving circuit, calculate the total loop resistance. Include input resistance, cable resistance, and other series-connected loads.\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/991_524659a5-cbca-478a-b812-374d1b70ec8e.png?v=1784875246\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013885976758,"sku":"991-25-50-02-01","price":215.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/991_1_cf7479f4-d249-4cb6-8560-99177135bd8a.jpg?v=1792734099","url":"https:\/\/www.plcsparehub.com\/products\/991-25-50-02-01-bently-nevada-991-series-thrust-position-transmitter-4-20ma","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}