{"product_id":"991-25-50-01-05-bently-nevada-991-thrust-transmitter","title":"991-25-50-01-05 Bently Nevada 991 Thrust Transmitter","description":"\u003ch3\u003e\u003cstrong\u003eBently Nevada 991-25-50-01-05 | Axial Thrust Transmitter\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #2e74b5;\"\u003eBently Nevada 991-25-50-01-05\u003c\/span\u003e\u003c\/strong\u003e is a DIN-rail-mounted transmitter designed for axial position and thrust-related displacement monitoring. It accepts one compatible \u003cstrong\u003e3300 NSv proximity probe\u003c\/strong\u003e and extension cable, then converts the measured displacement into a two-wire 4–20 mA DC signal.\u003c\/p\u003e\n\u003cp\u003eThis configuration uses a symmetrical \u003cstrong\u003e25-0-25 mil\u003c\/strong\u003e full-scale option and a 5.0 m system-length option. It supports integration with compatible PLC, DCS, and machinery monitoring inputs. Its NOT OK function drives the current output below 3.6 mA when a qualifying measurement-system fault occurs.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConfiguration Map | Decode the Ordering Number\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eConfiguration Meaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e991\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eThrust transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e25\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFull-scale option\u003c\/td\u003e\n\u003ctd\u003e25-0-25 mils\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e50\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem-length option\u003c\/td\u003e\n\u003ctd\u003e5.0 m (16.4 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting option\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN-rail clips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency approval option\u003c\/td\u003e\n\u003ctd\u003eCSA Division 2, ATEX Zone 0, ATEX Zone 2, and ABS maritime approval, as specified for this option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering-code structure:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e991\u003c\/strong\u003e — transmitter model\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-25\u003c\/strong\u003e — 25-0-25 mil full-scale option\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-50\u003c\/strong\u003e — 5.0 m system-length option\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-01\u003c\/strong\u003e — 35 mm DIN-rail mounting option\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-05\u003c\/strong\u003e — specified agency approval package\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlways verify the complete ordering code and the applicable approval documents before replacing a transmitter. Hazardous-area and maritime approvals apply only under their stated conditions and installation requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specification Register\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e991-25-50-01-05\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eThrust transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Purpose\u003c\/td\u003e\n\u003ctd\u003eAxial position \/ thrust-related displacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Input\u003c\/td\u003e\n\u003ctd\u003eOne non-contacting 3300 NSv proximity probe and extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull-Scale Option\u003c\/td\u003e\n\u003ctd\u003e25-0-25 mils\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e0.25–1.65 mm for Prox Out; suitable for 0.6-0-0.6 mm or 25-0-25 mil current-loop linear ranges\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd\u003e4–20 mA DC, two-wire configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e+12 to +35 V DC at transmitter terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Loop Accuracy\u003c\/td\u003e\n\u003ctd\u003eWithin ±1.5% of specified full-scale range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy Test Conditions\u003c\/td\u003e\n\u003ctd\u003eRated from TEST signal input to voltage measured across a 250 Ω loop resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Loop Resistance\u003c\/td\u003e\n\u003ctd\u003e1,000 Ω including cable at 35 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Current Limiting\u003c\/td\u003e\n\u003ctd\u003e23 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero and Span\u003c\/td\u003e\n\u003ctd\u003eNon-interacting external adjustments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOT OK Output Response\u003c\/td\u003e\n\u003ctd\u003eOutput falls below 3.6 mA within 100 μs after a NOT OK condition occurs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Recovery\u003c\/td\u003e\n\u003ctd\u003eOutput restored within 0.1 seconds after the NOT OK condition is removed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e−35°C to +85°C (−31°F to +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter Storage Temperature\u003c\/td\u003e\n\u003ctd\u003e−51°C to +100°C (−60°F to +212°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.43 kg (0.9 lbm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproval Option\u003c\/td\u003e\n\u003ctd\u003eCSA Division 2, ATEX Zone 0, ATEX Zone 2, and ABS maritime approval, subject to official documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eRange clarification:\u003c\/strong\u003e The 25-0-25 mil option describes a bidirectional measurement range around a central reference. Confirm the configured engineering range and scaling in the receiving system. Do not assume that every 4–20 mA channel automatically interprets the signal as a centered axial range.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHow It Fits into an Axial Position Monitoring Loop\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe transmitter converts a proximity probe measurement into a current signal that a compatible control or monitoring system can read. Accurate results depend on the probe assembly, mechanical target, supply voltage, loop resistance, and channel scaling.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe measurement:\u003c\/strong\u003e The compatible 3300 NSv probe senses the position of a conductive target without contact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal conversion:\u003c\/strong\u003e The transmitter converts the probe signal into a 4–20 mA output across the configured measurement range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem interface:\u003c\/strong\u003e A PLC, DCS, or monitoring input receives the current signal for display, trending, and alarm logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFault signaling:\u003c\/strong\u003e A qualifying NOT OK condition drives the output below 3.6 mA, allowing compatible receiving equipment to identify an abnormal measurement state.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField adjustment:\u003c\/strong\u003e External zero and span adjustments support calibration of the measurement output within the manufacturer's procedure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe transmitter supplies an axial displacement-related signal. It does not independently determine thrust force. Mechanical thrust interpretation depends on the machine design, probe location, target geometry, and configured alarm limits.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWhere Engineers Commonly Apply This Transmitter\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteam and gas turbines:\u003c\/strong\u003e Monitor axial shaft position as part of a broader machinery condition monitoring arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial compressors:\u003c\/strong\u003e Provide axial displacement data to compatible control and monitoring systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge pumps and rotating machinery:\u003c\/strong\u003e Track changes in shaft position where the equipment design supports proximity-probe measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower generation equipment:\u003c\/strong\u003e Integrate axial position measurements into operator displays, trend histories, and engineered alarm logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine machinery applications:\u003c\/strong\u003e Consider use where the required ABS approval and installation conditions are verified for the specific installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlant retrofits:\u003c\/strong\u003e Replace a matching transmitter where the probe system, range, mounting, power supply, and approvals align with the existing design.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Commissioning: Practical Checks\u003c\/strong\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm the measurement design.\u003c\/strong\u003e Verify the required axial measurement range, the probe's position relative to the target, and the machine manufacturer's measurement recommendations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the complete sensor assembly.\u003c\/strong\u003e Confirm the 3300 NSv probe and extension cable are compatible with the 5.0 m system-length configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect DIN-rail mounting.\u003c\/strong\u003e Secure the transmitter using the specified 35 mm DIN-rail clips and maintain access for wiring and adjustment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify the DC supply.\u003c\/strong\u003e Measure the voltage at the transmitter terminals. Ensure it remains within +12 to +35 V DC under operating load.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalculate loop resistance.\u003c\/strong\u003e Include field wiring, receiving-input resistance, and other series devices. The maximum stated resistance is 1,000 Ω at 35 V DC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfigure the analog input.\u003c\/strong\u003e Set the receiving channel for 4–20 mA and enter the correct bidirectional range and engineering units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck zero and span.\u003c\/strong\u003e Follow the manufacturer's calibration procedure. Avoid adjusting the transmitter to compensate for a mechanical alignment or probe-gap problem.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValidate fault handling.\u003c\/strong\u003e Confirm that the receiving system interprets current below 3.6 mA as intended and that recovery behavior matches the configured logic.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eFor hazardous-area installations, confirm the certificate, equipment marking, wiring method, and installation conditions against the actual site classification. The presence of an approval option does not by itself establish suitability for every hazardous location.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eField Diagnostics | From Symptom to Verification\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSymptom\u003c\/th\u003e\n\u003cth\u003ePotential Cause\u003c\/th\u003e\n\u003cth\u003eRecommended Check\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent output below 3.6 mA\u003c\/td\u003e\n\u003ctd\u003eNOT OK condition, probe fault, cable fault, or measurement-chain problem\u003c\/td\u003e\n\u003ctd\u003eVerify supply voltage, probe and extension-cable connections, and the manufacturer's fault-check procedure.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent reading is stuck at one value\u003c\/td\u003e\n\u003ctd\u003eInput signal issue, incorrect wiring, or a problem with the probe or target\u003c\/td\u003e\n\u003ctd\u003eCheck the loop current, inspect connections, and compare the measurement with a verified mechanical reference where available.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAxial reading has a consistent offset\u003c\/td\u003e\n\u003ctd\u003eIncorrect zero setting, probe positioning, target reference, or channel scaling\u003c\/td\u003e\n\u003ctd\u003eReview the machine's reference position, probe installation, transmitter zero, and receiving-system range.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading changes after maintenance\u003c\/td\u003e\n\u003ctd\u003eProbe position changed, wiring disturbed, or configuration altered\u003c\/td\u003e\n\u003ctd\u003eCompare pre- and post-maintenance records, inspect mounting and cable routing, and verify zero and span.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent signal is unstable\u003c\/td\u003e\n\u003ctd\u003eLoose connections, unstable supply, electrical interference, or mechanical movement\u003c\/td\u003e\n\u003ctd\u003eMeasure supply voltage under load, inspect terminals and shielding practices, and compare local measurements with the trend.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePLC\/DCS display disagrees with the measured loop current\u003c\/td\u003e\n\u003ctd\u003eIncorrect channel scaling, range direction, or engineering-unit conversion\u003c\/td\u003e\n\u003ctd\u003eVerify the 4–20 mA input configuration and confirm that the bidirectional 25-0-25 mil range is mapped correctly.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic caution:\u003c\/strong\u003e The NOT OK output helps identify a qualifying abnormal measurement condition, but it does not guarantee detection of every possible mechanical, wiring, or control-system fault. Diagnose the complete measurement loop rather than relying on current output alone.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eFor axial position monitoring, correct reference setup matters as much as the transmitter's electrical performance. A 25-0-25 mil range is centered around a reference point, so engineers must confirm the zero position and range direction before assigning alarm thresholds. A reversed or incorrectly scaled PLC\/DCS channel can make normal shaft movement appear abnormal—or hide a meaningful change.\u003c\/p\u003e\n\u003cp\u003eDuring a transmitter replacement, retain the original probe gap, cable identification, channel scaling, and calibration records where available. After installation, compare the displayed value against the transmitter loop current and the machine's documented reference position. If the reading changes after maintenance, investigate probe positioning and scaling before altering the span.\u003c\/p\u003e\n\u003cp\u003eFor turbine, compressor, and other critical rotating machinery, integrate the measurement into an engineered monitoring strategy. Confirm that alarm settings, trip logic, and any required independent protection functions follow the equipment manufacturer's and site's approved design.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How can I tell whether a centered 25-0-25 mil range is configured correctly in my DCS?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eReview the channel's lower and upper engineering limits, zero reference, and signal direction. Confirm the mapping against the transmitter configuration and a known reference condition. Do not assume a standard 4–20 mA input automatically supports a centered range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What should I compare when the new transmitter does not match the old unit's reading?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCompare the full ordering code, probe and extension-cable combination, probe position, zero and span settings, and receiving-channel scaling. Record loop current and displayed engineering units at the same operating condition to isolate the source of the discrepancy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Does the 5.0 m system-length option mean I can use any 5 m cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. System length refers to the compatible probe and extension-cable arrangement specified by the manufacturer. Confirm cable type, probe model, and the approved combined system configuration instead of selecting a cable based only on physical length.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: How should I assess whether this model suits a marine or hazardous-area installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMatch the equipment marking and approval documents to the installation's actual classification and applicable requirements. Confirm the full model suffix, environmental conditions, mounting, wiring method, and any vessel or site-specific approval requirements before purchase.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What information helps prevent ordering the wrong replacement transmitter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eProvide the complete model number, required axial range, installed probe and extension-cable details, mounting arrangement, supply voltage, analog input configuration, and required approvals. If possible, include the existing transmitter's nameplate information and the receiving channel's configured range.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWarranty, Shipping, and Package Details\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct:\u003c\/strong\u003e Bently Nevada 991-25-50-01-05 thrust transmitter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12-month warranty, subject to the seller's applicable terms and conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping options:\u003c\/strong\u003e FedEx, UPS, and DHL, subject to destination and shipment arrangements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage contents:\u003c\/strong\u003e One transmitter. Probe, extension cable, and other accessories are included only when explicitly listed in the quotation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder verification:\u003c\/strong\u003e Provide the complete model and application details to help confirm configuration compatibility and availability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRequest a quotation from Global PLC Spare HUB\u003c\/strong\u003e for the \u003cstrong\u003e991-25-50-01-05\u003c\/strong\u003e. Share your probe-system details and required approval conditions so the configuration can be checked before ordering.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/991_524659a5-cbca-478a-b812-374d1b70ec8e.png?v=1784875246\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013885878454,"sku":"991-25-50-01-05","price":218.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/991_6_954fc031-f274-4a97-9145-39a21afce672.jpg?v=1792734099","url":"https:\/\/www.plcsparehub.com\/products\/991-25-50-01-05-bently-nevada-991-thrust-transmitter","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}