{"product_id":"990-10-50-03-01-bently-nevada-990-vibration-transmitter","title":"990-10-50-03-01 Bently Nevada 990 Vibration Transmitter","description":"\u003ch3\u003e\u003cstrong\u003eBently Nevada 990-10-50-03-01 | 990 Vibration Transmitter\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #2e74b5;\"\u003eBently Nevada 990-10-50-03-01\u003c\/span\u003e\u003c\/strong\u003e is a two-wire vibration transmitter designed to interface with one compatible \u003cstrong\u003e3300 NSv proximity probe\u003c\/strong\u003e and its extension cable. It converts the probe measurement into a 4–20 mA DC signal for PLC, DCS, and machinery monitoring systems.\u003c\/p\u003e\n\u003cp\u003eThis configuration provides a full-scale range of \u003cstrong\u003e0–10 mils peak-to-peak (0–250 μm peak-to-peak)\u003c\/strong\u003e, a 5.0 m system length, DIN mounting clips and screws, and CSA Division 2 approval. Its NOT OK signal-defeat function drives the output below 3.6 mA when a qualifying transmitter or probe system fault occurs.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e01 | Configuration Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eUse the complete ordering code to distinguish the measuring range, probe-system length, mounting hardware, and approval configuration.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode Segment\u003c\/th\u003e\n\u003cth\u003eSelection\u003c\/th\u003e\n\u003cth\u003eConfiguration Meaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e990\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e990 series\u003c\/td\u003e\n\u003ctd\u003eVibration transmitter platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFull-scale option\u003c\/td\u003e\n\u003ctd\u003e0–10 mils pp (0–250 μm pp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e50\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem length option\u003c\/td\u003e\n\u003ctd\u003e5.0 m (16.4 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e03\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting option\u003c\/td\u003e\n\u003ctd\u003eDIN clips and screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency approval option\u003c\/td\u003e\n\u003ctd\u003eCSA Division 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eComplete model:\u003c\/strong\u003e 990 + 10 + 50 + 03 + 01 = \u003cstrong\u003e990-10-50-03-01\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eConfirm the ordering-code interpretation against the applicable manufacturer documentation before substituting another full-scale range, system length, mounting option, or approval variant.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e02 | Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e990-10-50-03-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/990-991-and-177230-transmitter\"\u003e990 Vibration Transmitter\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Input\u003c\/td\u003e\n\u003ctd\u003eOne non-contacting 3300 NSv proximity probe and extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull-Scale Range\u003c\/td\u003e\n\u003ctd\u003e0–10 mils peak-to-peak (0–250 μm peak-to-peak)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Length Option\u003c\/td\u003e\n\u003ctd\u003e5.0 m (16.4 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e+12 to +35 V DC at the transmitter terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e4–20 mA DC, two-wire configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoop Accuracy\u003c\/td\u003e\n\u003ctd\u003eWithin ±1.5% of specified full-scale range under stated test conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Loop Resistance\u003c\/td\u003e\n\u003ctd\u003e1,000 Ω including cable at 35 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Current Limiting\u003c\/td\u003e\n\u003ctd\u003e23 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero and Span\u003c\/td\u003e\n\u003ctd\u003eNon-interacting external adjustments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e5 Hz to 6,000 Hz, +0\/−3 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Gap\u003c\/td\u003e\n\u003ctd\u003e0.5–1.75 mm (20–55 mils) from target\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Target Size\u003c\/td\u003e\n\u003ctd\u003e9.5 mm (0.375 in) diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProximitor Sensor Output Cable\u003c\/td\u003e\n\u003ctd\u003eMaximum cable distance of 3 m (10 ft) at the BNC connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOT OK Response\u003c\/td\u003e\n\u003ctd\u003eOutput falls below 3.6 mA within 100 μs after a NOT OK condition occurs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Recovery\u003c\/td\u003e\n\u003ctd\u003eTypically restored within 2–3 seconds after the NOT OK condition clears\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN clips and screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproval Option\u003c\/td\u003e\n\u003ctd\u003eCSA Division 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecified Hazardous-Area Context\u003c\/td\u003e\n\u003ctd\u003eNonhazardous, Zone 2, or Division 2 locations, subject to applicable approvals and installation requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Note\u003c\/td\u003e\n\u003ctd\u003e28 V power supply specified for the stated hazardous-area application context; verify the approved installation design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter Weight\u003c\/td\u003e\n\u003ctd\u003e0.43 kg (0.9 lbm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry Information\u003c\/td\u003e\n\u003ctd\u003eSupplied description states Made in U.S.A.; verify marking on the actual unit when required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy note:\u003c\/strong\u003e The stated ±1.5% loop accuracy applies from the TEST signal input to the voltage measured across a 250 Ω loop resistance. This error is additional to the Prox Out incremental scale factor. Do not interpret it as total installed-system accuracy without considering the probe, cable, target, and receiving instrument.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e03 | Signal Path and System Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe transmitter forms part of a non-contacting displacement measurement chain. Correct performance depends on the complete probe, extension cable, target, power supply, and receiving input.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensing:\u003c\/strong\u003e The compatible 3300 NSv proximity probe measures shaft or target displacement without physical contact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal conversion:\u003c\/strong\u003e The transmitter converts the measurement into a two-wire 4–20 mA signal over its configured full-scale range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl-system interface:\u003c\/strong\u003e A compatible PLC, DCS, or monitoring input receives the current signal for display, trending, and alarm logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFault indication:\u003c\/strong\u003e When a NOT OK condition occurs, the transmitter drives the output below 3.6 mA within the specified response time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop design:\u003c\/strong\u003e The power supply must provide sufficient voltage for the transmitter and the total loop resistance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor a 4–20 mA input, 4 mA generally represents the configured lower measurement limit and 20 mA represents full scale. Confirm the receiving channel's scaling and fault-current interpretation during commissioning.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e04 | Suitable Equipment and Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRotating machinery:\u003c\/strong\u003e Integrate compatible shaft-displacement measurements into monitoring systems for pumps, compressors, and other rotating equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial process skids:\u003c\/strong\u003e Send vibration-related displacement data to PLC or DCS analog inputs for operator monitoring and process response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMachinery condition monitoring:\u003c\/strong\u003e Trend shaft movement over time to help identify changes that warrant further inspection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlant control and alarm systems:\u003c\/strong\u003e Use the 4–20 mA signal as an input to correctly engineered display, alarm, and supervisory logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance and retrofit projects:\u003c\/strong\u003e Replace a matching transmitter where the existing probe system, measurement range, wiring, and mounting arrangement are compatible.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe transmitter provides a displacement-related signal, not a universal vibration velocity or acceleration measurement. Verify the required measurement type and signal scaling before using it in a machinery protection design.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e05 | Installation and Commissioning Procedure\u003c\/strong\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify the part number:\u003c\/strong\u003e Check that the transmitter is 990-10-50-03-01 and that its full-scale, system-length, mounting, and approval options match the application.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the probe system:\u003c\/strong\u003e Confirm compatibility with the 3300 NSv proximity probe and extension cable. Verify the total system length against the approved system documentation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSet the probe gap:\u003c\/strong\u003e Position the probe within the specified 0.5–1.75 mm gap range. Use the manufacturer's setup procedure and appropriate measurement tools.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValidate the target:\u003c\/strong\u003e Confirm that the target diameter meets the 9.5 mm minimum and that target material and surface conditions suit the sensing system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck loop power:\u003c\/strong\u003e Supply +12 to +35 V DC at the transmitter terminals. Calculate the total loop resistance, including wiring and receiving-input resistance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify the receiving channel:\u003c\/strong\u003e Configure the PLC or DCS input for 4–20 mA and enter the correct engineering-unit scaling for the 0–10 mils pp range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest the complete loop:\u003c\/strong\u003e Use an approved test procedure to verify the current output, displayed value, fault response, and recovery behavior.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecord baseline readings:\u003c\/strong\u003e Document the probe gap, loop voltage, loop resistance, zero and span settings, and receiving-channel readings for future maintenance.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eFor installations in hazardous areas, follow the exact approval conditions, site electrical procedures, and manufacturer instructions. The stated 28 V supply context does not replace verification of the complete installation's suitability.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e06 | Diagnostic Guidance for Field Engineers\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSymptom\u003c\/th\u003e\n\u003cth\u003ePossible Cause\u003c\/th\u003e\n\u003cth\u003eRecommended Diagnostic Action\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoop current is below 3.6 mA\u003c\/td\u003e\n\u003ctd\u003eNOT OK condition, probe or cable problem, or loss of valid measurement\u003c\/td\u003e\n\u003ctd\u003eCheck transmitter supply, probe connections, extension cable, gap, and the manufacturer's NOT OK diagnostic procedure.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoop current remains near zero\u003c\/td\u003e\n\u003ctd\u003eOpen loop, missing supply, incorrect polarity, or wiring fault\u003c\/td\u003e\n\u003ctd\u003eMeasure DC voltage at the transmitter terminals and inspect loop continuity and polarity.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading is consistently offset\u003c\/td\u003e\n\u003ctd\u003eIncorrect probe gap, zero setting, target geometry, or receiving-channel scaling\u003c\/td\u003e\n\u003ctd\u003eRecheck the physical gap, zero adjustment, target dimensions, and PLC\/DCS range configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading fluctuates unexpectedly\u003c\/td\u003e\n\u003ctd\u003eLoose connections, electrical interference, mechanical movement, or unstable target conditions\u003c\/td\u003e\n\u003ctd\u003eInspect the wiring and mounting, compare local measurements with the control-system trend, and review machine operating conditions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal does not reach 20 mA at expected full scale\u003c\/td\u003e\n\u003ctd\u003eIncorrect span, incompatible probe-system configuration, insufficient loop voltage, or scaling mismatch\u003c\/td\u003e\n\u003ctd\u003eVerify the transmitter range, probe and cable compatibility, loop voltage under load, and receiving-channel configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal does not recover promptly after a fault\u003c\/td\u003e\n\u003ctd\u003eThe NOT OK condition remains, or the probe\/cable fault persists\u003c\/td\u003e\n\u003ctd\u003eConfirm the fault has cleared and allow the specified 2–3 second recovery interval before investigating further.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e The NOT OK output is a fault-indication behavior, not proof that every possible probe, cable, transmitter, or wiring fault will be detected. Follow the manufacturer's diagnostic procedure and validate the full measurement chain.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e07 | Global PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eFor the \u003cstrong\u003e990-10-50-03-01\u003c\/strong\u003e, three checks deserve priority during replacement and commissioning: probe-system compatibility, mechanical gap, and current-loop headroom. A transmitter may receive power and produce a plausible current even when the receiving channel uses the wrong engineering range. That error can distort alarm thresholds and historical trends.\u003c\/p\u003e\n\u003cp\u003eEngineers should calculate the total loop resistance at the actual supply voltage rather than relying only on the 1,000 Ω maximum stated at 35 V DC. Cable resistance, input resistance, and other series devices all consume available voltage. Confirm the required transmitter terminal voltage under the worst-case loop load.\u003c\/p\u003e\n\u003cp\u003eWhen a NOT OK signal appears, investigate the probe and extension cable before changing zero or span. Adjustments cannot correct a defective connection or an incompatible sensor system. After maintenance, compare the transmitter output with the receiving system and record the baseline for future trend analysis.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e08 | Frequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How do I determine whether the 5.0 m system-length option matches my installed probe assembly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIdentify the installed 3300 NSv probe and extension cable part numbers, then compare their approved combined system length with the transmitter configuration. Do not assume that physical cable length alone establishes electrical compatibility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What should I consider when connecting this transmitter to a PLC analog input?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConfirm that the input supports two-wire 4–20 mA loops, check the input resistance, and verify the supply voltage remaining at the transmitter. Configure the engineering range for 0–10 mils pp or 0–250 μm pp as required, and confirm how the PLC handles currents below 3.6 mA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can I use this model to measure vibration velocity directly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis model is specified for a 3300 NSv proximity probe and a displacement full-scale range. It does not directly provide a velocity measurement based on the supplied specifications. Select a suitable sensing and signal-conditioning system if the application requires velocity or acceleration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Why should the loop be tested at the receiving input as well as at the transmitter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe transmitter's output accuracy does not include every error introduced by field wiring, input resistance, channel configuration, or control-system scaling. Checking both ends helps identify wiring drops, incorrect input settings, and discrepancies between measured current and displayed engineering units.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What information should I provide when requesting a replacement quotation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eProvide the full transmitter part number, installed probe and extension-cable models, required measurement range, loop supply voltage, receiving-input type, mounting requirements, and hazardous-area classification. These details help verify configuration compatibility and reduce the risk of ordering a transmitter with the wrong options.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e09 | Warranty, Shipping, and Package Details\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct:\u003c\/strong\u003e Bently Nevada 990-10-50-03-01 vibration transmitter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12-month warranty, subject to the seller's applicable terms and conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping methods:\u003c\/strong\u003e FedEx, UPS, and DHL, subject to destination and shipment arrangements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage contents:\u003c\/strong\u003e One 990-10-50-03-01 transmitter. Probe, extension cable, and additional accessories are included only when explicitly listed in the quotation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrdering support:\u003c\/strong\u003e Provide the full part number and existing system details to help confirm compatibility and availability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRequest a quotation from Global PLC Spare HUB\u003c\/strong\u003e for the \u003cstrong\u003eBently Nevada 990-10-50-03-01\u003c\/strong\u003e. Our team can review your application details to help verify the required configuration before ordering.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/990_Graphs_and_Figures_8ba4a14f-832f-4772-a484-c09fd48b12f9.png?v=1784875470\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013924446390,"sku":"990-10-50-03-01","price":106.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/BentlyNevada990_2_909c33ab-170e-4915-ab06-911d600cec81.jpg?v=1792733812","url":"https:\/\/www.plcsparehub.com\/products\/990-10-50-03-01-bently-nevada-990-vibration-transmitter","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}