{"product_id":"990-08-xx-03-00-bently-nevada-probe-transmitter-4-20-ma-axial-monitoring","title":"990-08-XX-03-00 Bently Nevada Probe Transmitter | 4-20 mA Axial Monitoring","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview: Axial Motion Monitoring with a 4–20 mA Output\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #2e74b5;\"\u003eBently Nevada 990-08-XX-03-00\u003c\/span\u003e\u003c\/strong\u003e is a probe vibration transmitter configuration for axial displacement monitoring. It converts a compatible proximity probe signal into a standard \u003cstrong\u003e4–20 mA current output\u003c\/strong\u003e for industrial control and monitoring systems.\u003c\/p\u003e\n\u003cp\u003eThe transmitter accepts one non-contacting \u003cstrong\u003e3300 NSv proximity probe\u003c\/strong\u003e and its compatible extension cable. Its two-wire loop design supports integration with PLC analog inputs, DCS controllers, and other compatible current-loop receivers.\u003c\/p\u003e\n\u003cp\u003eThe 08 full-scale option represents \u003cstrong\u003e0–8 mils peak-to-peak (0–200 μm peak-to-peak)\u003c\/strong\u003e. The 03 mounting option specifies DIN clips and screws. The 00 agency approval option indicates that no agency approval is specified by that ordering code.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Bently Nevada\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Number:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color: #2e74b5;\"\u003e990-08-XX-03-00\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Probe vibration transmitter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrdering Model Description:\u003c\/strong\u003e 991 thrust transmitter family, as provided in the ordering information\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Purpose:\u003c\/strong\u003e Axial displacement monitoring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput:\u003c\/strong\u003e 4–20 mA DC, two-wire configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail using clips and screws\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturing Origin:\u003c\/strong\u003e USA, according to the supplied product information\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12 months, subject to supplier terms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #2e74b5;\"\u003e990-08-XX-03-00\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eProbe vibration transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Application\u003c\/td\u003e\n\u003ctd\u003eAxial displacement \/ thrust position monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Input\u003c\/td\u003e\n\u003ctd\u003eOne non-contacting 3300 NSv proximity probe with compatible extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull-Scale Option\u003c\/td\u003e\n\u003ctd\u003e08: 0–8 mils peak-to-peak (0–200 μm peak-to-peak)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Length Option\u003c\/td\u003e\n\u003ctd\u003eXX: Specify the required MOD number\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Option\u003c\/td\u003e\n\u003ctd\u003e03: DIN clips and screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval Option\u003c\/td\u003e\n\u003ctd\u003e00: Not required by the ordering option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e4–20 mA DC, two-wire loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter Supply\u003c\/td\u003e\n\u003ctd\u003e+12 to +35 VDC at the transmitter terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecified Linear Range\u003c\/td\u003e\n\u003ctd\u003e0.25–1.65 mm for Prox Out, according to the supplied specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoop Accuracy\u003c\/td\u003e\n\u003ctd\u003eTypically within ±1.5% of specified full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Loop Resistance\u003c\/td\u003e\n\u003ctd\u003e1,000 Ω, including cable, at 35 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Limiting\u003c\/td\u003e\n\u003ctd\u003e23 mA typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero and Span Adjustment\u003c\/td\u003e\n\u003ctd\u003eExternal, non-interacting adjustments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNot OK Response\u003c\/td\u003e\n\u003ctd\u003eOutput falls below 3.6 mA within 100 μs after a Not OK condition occurs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Recovery\u003c\/td\u003e\n\u003ctd\u003eOutput returns within 0.1 seconds after the Not OK condition clears\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-35°C to +85°C (-31°F to +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-51°C to +100°C (-60°F to +212°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter Weight\u003c\/td\u003e\n\u003ctd\u003e0.43 kg (0.9 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration note:\u003c\/strong\u003e The XX system-length field requires the applicable MOD number. Confirm this value before ordering to match the transmitter with the installed probe system.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHow the Transmitter Supports Machinery Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe transmitter converts a compatible proximity probe measurement into a current signal that downstream equipment can interpret. This arrangement allows control-system engineers to monitor axial movement without relying solely on a local vibration rack display.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe Measurement:\u003c\/strong\u003e The 3300 NSv proximity probe senses the position of a compatible conductive target.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Conversion:\u003c\/strong\u003e The transmitter converts the probe system signal into a proportional 4–20 mA output within its configured range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl-System Integration:\u003c\/strong\u003e A compatible PLC, DCS, or monitoring input reads the current signal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm Processing:\u003c\/strong\u003e Engineers configure warning and trip thresholds in the receiving system when the application requires them.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFault Investigation:\u003c\/strong\u003e Technicians compare the current signal with independent measurements and operating conditions.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e The transmitter provides a measurement signal, not a complete machine shutdown function. The receiving system must implement the required alarms, interlocks, and protection logic.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSignal Performance and Loop Design\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eReliable readings depend on correct probe compatibility, system length, loop power, and input configuration. Engineers should verify these parameters before connecting the transmitter to an operating control system.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop Power:\u003c\/strong\u003e Supply 12–35 VDC at the transmitter terminals. Account for voltage drops across the receiver, wiring, and other loop components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad Resistance:\u003c\/strong\u003e Keep the total loop resistance within 1,000 Ω at a 35 VDC supply. Recalculate the allowable load at lower supply voltages.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Scaling:\u003c\/strong\u003e Configure the receiving analog input for 4–20 mA and apply the correct engineering-unit range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e The stated typical accuracy is ±1.5% of full scale under the specified test conditions. The reference uses the TEST signal input and voltage measured across a 250 Ω loop resistance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero and Span:\u003c\/strong\u003e Use the external adjustments during authorized calibration. Record the initial and final readings for traceability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFault Signaling:\u003c\/strong\u003e The specified Not OK response drops below 3.6 mA. Confirm that the receiving device recognizes this condition correctly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 0–8 mils peak-to-peak option describes the ordered full-scale measurement setting. Do not assume that every output configuration has the same engineering-unit scaling.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eRecommended Equipment and Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eEquipment or System\u003c\/th\u003e\n\u003cth\u003eApplication\u003c\/th\u003e\n\u003cth\u003eEngineering Benefit\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSteam Turbines\u003c\/td\u003e\n\u003ctd\u003eAxial shaft position trending\u003c\/td\u003e\n\u003ctd\u003eHelps operators identify changes in thrust position.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressors\u003c\/td\u003e\n\u003ctd\u003eThrust movement monitoring\u003c\/td\u003e\n\u003ctd\u003eSupports investigation of changing axial position during load changes.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial Pumps\u003c\/td\u003e\n\u003ctd\u003eAxial displacement observation\u003c\/td\u003e\n\u003ctd\u003eProvides a current signal for compatible control-system monitoring.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGearboxes\u003c\/td\u003e\n\u003ctd\u003eAxial movement trending\u003c\/td\u003e\n\u003ctd\u003eHelps maintenance teams compare movement across operating conditions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePLC Systems\u003c\/td\u003e\n\u003ctd\u003eAnalog input acquisition\u003c\/td\u003e\n\u003ctd\u003eAllows current-loop measurements to enter the control application.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDCS Systems\u003c\/td\u003e\n\u003ctd\u003eProcess and machinery monitoring\u003c\/td\u003e\n\u003ctd\u003eSupports centralized trend displays and alarm handling.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eUse this transmitter only where the measured variable, probe arrangement, and required protection function match the application. Confirm the equipment manufacturer's requirements before applying it to a critical machine.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Commissioning Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 1 — Confirm the System Length:\u003c\/strong\u003e Identify the required MOD number and verify the complete probe system configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 2 — Mount the Transmitter:\u003c\/strong\u003e Secure the DIN clips and screws to a suitable rail or approved mounting arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 3 — Verify the Probe:\u003c\/strong\u003e Confirm that the installed 3300 NSv probe and extension cable match the transmitter requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 4 — Check the Power Supply:\u003c\/strong\u003e Measure the DC voltage at the transmitter terminals before commissioning.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 5 — Inspect the Loop:\u003c\/strong\u003e Check polarity, terminal tightness, cable continuity, and total loop resistance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 6 — Configure the Analog Input:\u003c\/strong\u003e Select 4–20 mA operation and set the correct engineering-unit scaling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 7 — Verify the Output:\u003c\/strong\u003e Compare the current output against an approved test signal or known operating condition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 8 — Test Fault Handling:\u003c\/strong\u003e Verify how the PLC or DCS responds when the transmitter reports a Not OK condition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 9 — Document the Results:\u003c\/strong\u003e Record the MOD number, calibration settings, supply voltage, output values, and alarm thresholds.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFollow approved site procedures before disconnecting any machinery protection circuit. Do not adjust zero or span while relying on unverified process measurements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagnostic Capabilities and Field Troubleshooting\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe transmitter's current output gives technicians a useful starting point for diagnosing measurement-loop problems. Correct interpretation requires the configured measurement range and the receiver's fault-handling logic.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eObserved Condition\u003c\/th\u003e\n\u003cth\u003ePossible Cause\u003c\/th\u003e\n\u003cth\u003eRecommended Check\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput below 3.6 mA\u003c\/td\u003e\n\u003ctd\u003eNot OK condition, probe-system fault, or wiring issue\u003c\/td\u003e\n\u003ctd\u003eCheck transmitter status, probe connections, supply voltage, and the receiver's fault interpretation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput remains near 4 mA\u003c\/td\u003e\n\u003ctd\u003eLow measured value, incorrect scaling, or incorrect adjustment\u003c\/td\u003e\n\u003ctd\u003eVerify the actual axial position, configured range, and zero setting.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput remains near 20 mA\u003c\/td\u003e\n\u003ctd\u003eHigh measured value, incorrect scaling, or span adjustment issue\u003c\/td\u003e\n\u003ctd\u003eCheck the operating position and confirm the intended full-scale configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal fluctuates unexpectedly\u003c\/td\u003e\n\u003ctd\u003eLoose wiring, electrical interference, unstable probe readings, or machine movement\u003c\/td\u003e\n\u003ctd\u003eCompare loop current with independent measurements and inspect wiring and mounting.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePLC and field readings disagree\u003c\/td\u003e\n\u003ctd\u003eIncorrect input scaling, loop resistance, or analog input configuration\u003c\/td\u003e\n\u003ctd\u003eMeasure the loop current and verify the PLC input configuration and engineering-unit conversion.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFault clears but readings remain abnormal\u003c\/td\u003e\n\u003ctd\u003ePersistent probe, cable, calibration, or mechanical issue\u003c\/td\u003e\n\u003ctd\u003eCheck the complete probe system and confirm the calibration against an approved reference.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eField example:\u003c\/strong\u003e A turbine axial-position trend may suddenly fall below its normal operating range after maintenance. Before changing alarm limits, technicians should check the transmitter supply, probe connections, current loop, and receiving-channel scaling.\u003c\/p\u003e\n\u003cp\u003eThese checks help distinguish electrical faults from genuine shaft movement. They do not replace the machine manufacturer's protection procedures or an independent mechanical assessment.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMechanical and Environmental Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe Tip:\u003c\/strong\u003e Polyphenylene sulfide (PPS).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe Case:\u003c\/strong\u003e AISI 303 or 304 stainless steel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe Cable:\u003c\/strong\u003e 75 Ω coaxial cable with fluoroethylene propylene (FEP) insulation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Cable Armor:\u003c\/strong\u003e Flexible AISI 302 stainless steel, with an optional FEP outer jacket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Specified Tensile Strength:\u003c\/strong\u003e 222 N (50 lbf) between the probe case and probe lead.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransmitter Temperature:\u003c\/strong\u003e -35°C to +85°C during operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -51°C to +100°C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProtect probe leads from sharp bends, crushing, abrasion, and excessive pulling force. Route signal cables away from high-current conductors where practical, and follow the approved grounding and shielding scheme.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eFor axial monitoring, engineers should prioritize correct system length and signal scaling before investigating small changes in the 4–20 mA trend. An incorrect MOD number or receiver range can create misleading readings even when the loop appears electrically healthy.\u003c\/p\u003e\n\u003cp\u003eDuring a turbine overhaul, for example, a maintenance team may replace a proximity probe while retaining the existing transmitter. The team should verify the replacement probe's compatibility, extension cable arrangement, and system length before returning the channel to service.\u003c\/p\u003e\n\u003cp\u003eAfter commissioning, technicians should record the current output at a known operating condition. They should also document the configured zero, span, alarm thresholds, and response to a Not OK condition.\u003c\/p\u003e\n\u003cp\u003eThis approach improves fault isolation and helps prevent unnecessary transmitter replacement. It also gives the next maintenance team a clear reference for evaluating changes in axial position.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePackaging, Warranty, and Shipping\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct:\u003c\/strong\u003e Bently Nevada 990-08-XX-03-00 probe vibration transmitter configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12 months, subject to the supplier's applicable terms and conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Carriers:\u003c\/strong\u003e FedEx, UPS, and DHL, subject to destination and service availability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch Target:\u003c\/strong\u003e 24–48 hours after order confirmation, subject to stock verification and order processing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder Verification:\u003c\/strong\u003e Confirm the complete part number and required MOD number before dispatch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Contents:\u003c\/strong\u003e Confirm the transmitter, mounting accessories, and included documentation against the supplier's packing list.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Why does the XX code require confirmation before purchase?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe XX field represents a system-length option that requires a MOD number. The correct value depends on the intended probe system configuration. Confirm the existing system documentation before ordering a replacement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: How should engineers interpret a current output that changes after a machine load change?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFirst, compare the change with the expected axial movement and the configured measurement range. Check the machine operating condition and verify the signal against independent data before treating the change as a fault.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What is the most useful commissioning record for future troubleshooting?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecord the MOD number, transmitter supply voltage, loop current, analog input scaling, and normal operating readings. Include alarm thresholds and the observed response to a verified Not OK condition.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: How can a buyer determine whether this transmitter suits an existing control cabinet?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConfirm the DIN mounting arrangement, available DC supply, input resistance, and two-wire 4–20 mA interface. Check the required engineering-unit range and the receiving input's handling of signals below 3.6 mA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: When should a technician adjust zero and span instead of replacing the transmitter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAdjustments may be appropriate when an approved calibration test identifies a correctable offset or scaling error. Verify the probe system, MOD number, supply voltage, and loop configuration first. Replace components only after testing identifies a fault and approved procedures permit the change.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eRequest Pricing and Technical Confirmation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eContact Global PLC Spare HUB to request a quotation for the \u003cstrong\u003e\u003cspan style=\"color: #2e74b5;\"\u003eBently Nevada 990-08-XX-03-00\u003c\/span\u003e\u003c\/strong\u003e. Provide the required MOD number, quantity, and intended application to help verify system compatibility before purchase.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/990_Graphs_and_Figures_8ba4a14f-832f-4772-a484-c09fd48b12f9.png?v=1784875470\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013971796150,"sku":"990-08-XX-03-00","price":145.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/BentlyNevada990_5_1ccb7293-c5e2-4bc9-83a3-eb4bf01d7f67.jpg?v=1792463940","url":"https:\/\/www.plcsparehub.com\/products\/990-08-xx-03-00-bently-nevada-probe-transmitter-4-20-ma-axial-monitoring","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}