{"product_id":"9200-09-01-02-01-bently-nevada-seismoprobe-velocity-transducer","title":"9200-09-01-02-01 Bently Nevada Seismoprobe Velocity Transducer","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview | Two-Wire Velocity Sensing Technology\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #0070c0;\"\u003eBently Nevada 9200-09-01-02-01\u003c\/span\u003e\u003c\/strong\u003e is a Two-Wire Velocity Seismoprobe Transducer for industrial machinery vibration monitoring.\u003c\/p\u003e\n\u003cp\u003eThis transducer converts casing vibration velocity into an electrical signal. Its two-wire configuration supports connection to compatible vibration monitoring circuits.\u003c\/p\u003e\n\u003cp\u003eThe sensor provides a nominal sensitivity of \u003cstrong\u003e20 mV\/mm\/s (500 mV\/in\/s), ±5%\u003c\/strong\u003e. Its specified minimum operating frequency is \u003cstrong\u003e15 Hz (900 cpm)\u003c\/strong\u003e. These characteristics support machinery vibration measurement where velocity monitoring is required.\u003c\/p\u003e\n\u003cp\u003eThe selected configuration includes a \u003cstrong\u003etop-mounted connector without an integral cable\u003c\/strong\u003e. Its circular mounting base uses a \u003cstrong\u003e1\/4-28 UNF stud\u003c\/strong\u003e. The specified mounting orientation is 0° ±180°.\u003c\/p\u003e\n\u003cp\u003eThe housing uses anodized A204 aluminum. A neoprene gasket provides the specified sealing interface. The CSA approval option supports installations requiring the applicable certification.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Engineering Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Type:\u003c\/strong\u003e Two-wire vibration velocity transducer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Sensitivity:\u003c\/strong\u003e 20 mV\/mm\/s, ±5%.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Operating Frequency:\u003c\/strong\u003e 15 Hz (900 cpm).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVelocity Range:\u003c\/strong\u003e 25 mm\/s (1 in\/s) under specified test conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Configuration:\u003c\/strong\u003e Top mount, without integral cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Interface:\u003c\/strong\u003e Circular base with 1\/4-28 UNF stud.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAgency Approval Option:\u003c\/strong\u003e CSA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing Material:\u003c\/strong\u003e Anodized A204 aluminum.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory Warranty:\u003c\/strong\u003e 12 months.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eOrdering Code Architecture | Configuration Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe complete ordering number identifies the transducer type, mounting orientation, connector arrangement, mounting base, and agency approval.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode Segment\u003c\/th\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003eTechnical Meaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e9200\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eTwo-Wire Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-09\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting Angle \/ Minimum Frequency\u003c\/td\u003e\n\u003ctd\u003e0° ±180°, 15 Hz (900 cpm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConnector Option\u003c\/td\u003e\n\u003ctd\u003eTop mount, no cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting Base Option\u003c\/td\u003e\n\u003ctd\u003eCircular base, 1\/4-28 UNF stud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency Approval\u003c\/td\u003e\n\u003ctd\u003eCSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration Identification Tree\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan style=\"color: #0070c0;\"\u003e9200\u003c\/span\u003e — Two-Wire Transducer\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Angle \/ Frequency: -09\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eSpecified orientation: 0° ±180°.\u003c\/li\u003e\n\u003cli\u003eMinimum operating frequency: 15 Hz.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Arrangement: -01\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eTop-mounted connector.\u003c\/li\u003e\n\u003cli\u003eNo integral cable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Base: -02\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eCircular mounting base.\u003c\/li\u003e\n\u003cli\u003e1\/4-28 UNF stud.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAgency Approval: -01\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eCSA approval option.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Verification:\u003c\/strong\u003e Match every suffix against the existing installation. Pay particular attention to connector orientation and mounting-base configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Data | Electrical Measurement Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e9200-09-01-02-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003e9200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eSeismoprobe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTwo-Wire Velocity Seismoprobe Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Principle\u003c\/td\u003e\n\u003ctd\u003eVelocity transduction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Sensitivity\u003c\/td\u003e\n\u003ctd\u003e20 mV\/mm\/s (500 mV\/in\/s), ±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Operating Frequency\u003c\/td\u003e\n\u003ctd\u003e15 Hz (900 cpm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Load\u003c\/td\u003e\n\u003ctd\u003e10 kΩ between terminals A and B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Measurement\u003c\/td\u003e\n\u003ctd\u003eAcross pins A and B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity Temperature Coefficient\u003c\/td\u003e\n\u003ctd\u003e0.2%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDynamic Operating Range\u003c\/td\u003e\n\u003ctd\u003e2.54 mm (0.100 in) peak-to-peak maximum displacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVelocity Range\u003c\/td\u003e\n\u003ctd\u003e25 mm\/s (1 in\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVelocity Test Conditions\u003c\/td\u003e\n\u003ctd\u003e+22°C, 100 Hz casing vibration, 10 kΩ load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Resistance\u003c\/td\u003e\n\u003ctd\u003e1.25 kΩ ±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-Coil Inductance\u003c\/td\u003e\n\u003ctd\u003e125 mH typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Note:\u003c\/strong\u003e The sensitivity specification requires proper termination and orientation at the calibration angle. The 25 mm\/s velocity range also uses specific test conditions.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMechanical Construction | Housing and Mounting Interface\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Orientation\u003c\/td\u003e\n\u003ctd\u003e0° ±180°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Position\u003c\/td\u003e\n\u003ctd\u003eTop mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegral Cable\u003c\/td\u003e\n\u003ctd\u003eNot included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Base\u003c\/td\u003e\n\u003ctd\u003eCircular\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Stud\u003c\/td\u003e\n\u003ctd\u003e1\/4-28 UNF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Material\u003c\/td\u003e\n\u003ctd\u003eAnodized A204 aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGasket Material\u003c\/td\u003e\n\u003ctd\u003eNeoprene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Height\u003c\/td\u003e\n\u003ctd\u003e102 mm (4 in), depending on connector option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Diameter\u003c\/td\u003e\n\u003ctd\u003e41 mm (1.6 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Weight\u003c\/td\u003e\n\u003ctd\u003e300 g (10.5 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe circular base provides a defined mounting interface. The 1\/4-28 UNF stud determines the mechanical connection requirements.\u003c\/p\u003e\n\u003cp\u003eThe top-mounted connector simplifies access from above the mounting position. The no-cable configuration requires a compatible external connection arrangement.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Specifications | Operating Conditions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironmental Parameter\u003c\/th\u003e\n\u003cth\u003e9200 Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-29°C to +121°C (-20°F to +250°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-29°C to +121°C (-20°F to +250°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003eUp to 95%, noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegral Cable Configuration\u003c\/td\u003e\n\u003ctd\u003eUp to 100% humidity, non-submerged, when ordered with integral cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Resistance\u003c\/td\u003e\n\u003ctd\u003eDust and moisture resistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Configuration Notice:\u003c\/strong\u003e The supplied documentation also lists a -29°C to +204°C range for model 74712. This rating does not apply to the standard 9200 transducer.\u003c\/p\u003e\n\u003cp\u003eFor this product, use the specified \u003cstrong\u003e-29°C to +121°C\u003c\/strong\u003e operating and storage limits.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConnector and Signal Interface\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe selected \u003cstrong\u003e-01 connector option\u003c\/strong\u003e uses a top-mounted connection without an integral cable. Engineers must verify the external cable and termination arrangement before commissioning.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Position:\u003c\/strong\u003e Top-mounted.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Configuration:\u003c\/strong\u003e No integral cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Termination:\u003c\/strong\u003e 10 kΩ calibration load between terminals A and B.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Measurement:\u003c\/strong\u003e Across pins A and B.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Sensitivity:\u003c\/strong\u003e 20 mV\/mm\/s.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eMaintain the specified calibration load when checking sensitivity. Different termination conditions may affect the measured output.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/9200_74712_dd4859fa-439b-4791-8da8-cfbb9a032efe.png?v=1795069263\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013882372278,"sku":"9200-09-01-02-01","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/Bently920074712_3_cb573578-83c0-4daa-91c2-e2ee97159437.jpg?v=1795069256","url":"https:\/\/www.plcsparehub.com\/products\/9200-09-01-02-01-bently-nevada-seismoprobe-velocity-transducer","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}