{"product_id":"9200-06-02-01-00-9200-bently-nevada-two-wire-sensor-probe","title":"9200-06-02-01-00 9200 Bently Nevada Two-Wire Sensor Probe","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eBently Nevada 9200-06-02-01-00\u003c\/strong\u003e\u003c\/span\u003e is a self-generating, two-wire electrodynamic velocity sensor designed to measure absolute structural vibration on industrial machinery. As part of the classic \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e9200 Seismoprobe\u003c\/strong\u003e\u003c\/span\u003e series, this transducer operates without external power by utilizing a spring-mass coil moving within a permanent magnetic field. It provides high-output voltage proportional to casing velocity, making it an essential instrument for continuous monitoring on medium-speed rotating machinery.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConfiguration Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eUnderstanding the exact option codes for part number \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e9200-06-02-01-00\u003c\/strong\u003e\u003c\/span\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e9200\u003c\/strong\u003e\u003c\/span\u003e — Base Model: Two-Wire Velocity Seismoprobe Transducer\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e-06\u003c\/strong\u003e — Mounting Angle \u0026amp; Frequency: 0° ±100° orientation; minimum operating frequency of 10 Hz (600 cpm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-02\u003c\/strong\u003e — Connector Type: Side-mount connector (no attached cable assembly)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-01\u003c\/strong\u003e — Mounting Base: Circular base with a 1\/4-20 UNC threaded stud\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-00\u003c\/strong\u003e — Agency Approvals: No hazardous area approvals required (standard industrial construction)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications Matrix\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\" cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35%;\"\u003e\u003cstrong\u003eBrand \u0026amp; Manufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eBently Nevada\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e9200-06-02-01-00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e9200 Seismoprobe Series\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo-wire electrodynamic self-generating velocity sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibrated Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 mV\/mm\/s (500 mV\/in\/s) ±5% with 10 kΩ termination load at calibration angle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDynamic Operating Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.54 mm (0.100 in) peak-to-peak maximum physical displacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVelocity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 mm\/s (1 in\/s) peak vibration at +22°C and 100 Hz into a 10 kΩ load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Electrical Parameters\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCoil resistance: 1.25 kΩ ±5%; Locked coil inductance: 125 mH typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermal Sensitivity Drift\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2% per °C temperature coefficient\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-29°C to +121°C (-20°F to +250°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure \u0026amp; Materials\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnodized aluminum A204 case and adapter; Neoprene internal sealing gaskets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDust and moisture resistant (up to 95% relative humidity, non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Dimensions \u0026amp; Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHeight: 102 mm (4.0 in) typical; Outer Diameter: 41 mm (1.6 in); Weight: 300 g (10.5 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eVariant Comparison \u0026amp; Engineering Recommendations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSelecting the correct \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e9200 Seismoprobe\u003c\/strong\u003e\u003c\/span\u003e variant depends on physical mounting orientation and signal connection preferences:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTarget Variant:\u003c\/strong\u003e \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e9200-06-02-01-00\u003c\/strong\u003e\u003c\/span\u003e features a 0° ±100° mounting angle (primarily vertical\/upward configurations), side-mount connector without attached cabling, and a 1\/4-20 UNC circular stud base.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlternative Variant:\u003c\/strong\u003e Compare with \u003ca href=\"https:\/\/www.plcsparehub.com\/products\/bently-nevada-9200-03-05-05-00-two-wire-velocity-seismoprobe\"\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e9200-03-05-05-00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e. That model provides a 90° ±100° mounting orientation (designed for horizontal shaft measurements), top-mount integral cable connection, and hazardous area approvals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEngineering Selection Tip:\u003c\/strong\u003e Match the option code precisely to your mounting plane. Installing a vertical variant like \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e9200-06-02-01-00\u003c\/strong\u003e\u003c\/span\u003e in a horizontal axis will cause the internal moving coil to rest against its physical stops, resulting in severe signal distortion and clipping.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTarget Applications \u0026amp; Machinery Health Diagnostics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCasing vibration tracking on slow-to-medium speed electric induction motors\u003c\/li\u003e\n\u003cli\u003eAbsolute structural velocity monitoring on heavy industrial fans and blowers\u003c\/li\u003e\n\u003cli\u003eBearing pedestal evaluation on gearboxes and balance-of-plant pumps\u003c\/li\u003e\n\u003cli\u003eDetection of structural unbalance, mechanical looseness, and foundation resonance\u003c\/li\u003e\n\u003cli\u003eFFT spectral analysis for tracking 1X and 2X rotational harmonic frequencies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB Insights \u0026amp; Field Experience\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eBecause the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e9200 Seismoprobe\u003c\/strong\u003e\u003c\/span\u003e relies on a moving mass suspended by internal springs, physical orientation dictates calibration accuracy. In plant audits, our field engineers frequently find erroneous readings caused by using an incorrect option code for a given mounting angle. For the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e9200-06-02-01-00\u003c\/strong\u003e\u003c\/span\u003e, ensure the sensor is installed within 100° of true vertical. Furthermore, since this unit features a side-mount connector without an attached cable, always apply strain relief to the mating field wiring to prevent mechanical wear on the connector pins during high-amplitude machinery vibration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Does the 9200-06-02-01-00 require an external power supply to operate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: No. The moving-coil construction is self-generating, producing a voltage directly proportional to vibration velocity without external excitation power.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the primary cause of signal clipping when commissioning a 9200 series transducer?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: Signal clipping usually occurs when the physical mounting angle deviates beyond the specified calibration range, causing the internal coil assembly to bottom out against its internal housing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: How do I select between a side-mount connector and an integral cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: Choose side-mount connectors like option 02 when tight overhead clearance prevents top-cable entry, or when quick-disconnect cable replacement is required during maintenance overhauls.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Why must the 9200 transducer output be terminated with a 10 kΩ load?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA4: The 20 mV\/mm\/s sensitivity calibration is factory-certified across a 10 kΩ load impedance. Deviating significantly from this load resistance will shift the effective scale factor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: Can this velocity transducer be used to measure high-frequency gear mesh frequencies above 1 kHz?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA5: Electrodynamic velocity probes have moving internal parts with mechanical resonance limits. For frequencies well above 1 kHz, piezoceramic accelerometers are generally recommended over moving-coil velocity transducers.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Fulfillment, Packaging \u0026amp; Warranty Terms\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Condition:\u003c\/strong\u003e Brand new, unused, factory-sealed in original packaging\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging Contents:\u003c\/strong\u003e 1x \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eBently Nevada 9200-06-02-01-00\u003c\/strong\u003e\u003c\/span\u003e Two-Wire Velocity Seismoprobe Transducer\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHandling \u0026amp; Dispatch:\u003c\/strong\u003e Expedited warehouse processing with shipment in 24 to 48 hours\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlobal Logistics:\u003c\/strong\u003e Door-to-door worldwide delivery via express couriers (FedEx, UPS, DHL)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty Coverage:\u003c\/strong\u003e Fully backed by a 12-month comprehensive factory warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/9200_74712.png?v=1784875507\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013971337398,"sku":"9200-06-02-01-00","price":214.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/9200_3_c74e5c17-18ca-461e-85d9-7bcc40efe63a.jpg?v=1784875528","url":"https:\/\/www.plcsparehub.com\/products\/9200-06-02-01-00-9200-bently-nevada-two-wire-sensor-probe","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}