{"product_id":"9200-03-24-10-00-bently-nevada-precision-9200-series-velocity-transducer","title":"9200-03-24-10-00 | Bently Nevada Precision 9200 Series Velocity Transducer","description":"\u003ch2\u003e\u003cstrong\u003e9200-03-24-10-00 Bently Nevada Two-Wire Velocity Seismoprobe Transducer\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 9200-03-24-10-00\u003c\/strong\u003e is a two-wire velocity transducer designed to measure casing vibration on rotating machinery. Its sensitivity is 20 mV\/mm\/s (500 mV\/in\/s) when properly terminated and oriented at the calibration angle. Engineers can use its velocity output for machinery condition monitoring when the installation and signal-processing requirements match the application.\u003c\/p\u003e\n\u003cp\u003eThis configuration specifies a 90° mounting orientation, a 4.5 Hz minimum operating frequency, a 24 ft cable option, and a circular mounting base with an M10 × 1 stud. The approval suffix indicates that no agency approvals are required for this configuration.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Bently Nevada\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e 9200-03-24-10-00\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e 9200 Two-Wire Transducer\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e Velocity Seismoprobe Transducer\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondition:\u003c\/strong\u003e New and original in factory packing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory warranty:\u003c\/strong\u003e 12 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e01 | Configuration Tree and Suffix Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cpre\u003e9200 - 03 - 24 - 10 - 00\n  │     │    │    │    └── 00: No agency approvals required\n  │     │    │    └─────── 10: Circular mounting base; M10 × 1 stud\n  │     │    └──────────── 24: 24 ft cable option\n  │     └───────────────── 03: 90° ±2.5° mounting angle;\n  │                          4.5 Hz (270 cpm) minimum operating frequency\n  └──────────────────────── 9200: Two-wire transducer family\u003c\/pre\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering checks:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm the required mounting orientation and available mounting space.\u003c\/li\u003e\n\u003cli\u003eVerify that a 24 ft cable reaches the signal termination point without unsafe routing or extensions.\u003c\/li\u003e\n\u003cli\u003eConfirm the circular base and M10 × 1 stud match the machine mounting arrangement.\u003c\/li\u003e\n\u003cli\u003eCheck site approval requirements before specifying the 00 suffix.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e02 | Technical Specifications and Measurement Limits\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eEngineering consideration\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer type\u003c\/td\u003e\n\u003ctd\u003eTwo-wire velocity transducer\u003c\/td\u003e\n\u003ctd\u003eConfirm the receiving instrument supports the specified sensor output.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e20 mV\/mm\/s (500 mV\/in\/s), ±5%\u003c\/td\u003e\n\u003ctd\u003eAccuracy depends on proper termination and orientation at the calibration angle.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration load\u003c\/td\u003e\n\u003ctd\u003e10 kΩ\u003c\/td\u003e\n\u003ctd\u003eConnect the load between terminals A and B and measure the output across A and B.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd\u003e0.2%\/°C\u003c\/td\u003e\n\u003ctd\u003eConsider temperature-related sensitivity changes when interpreting trend data.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum operating frequency\u003c\/td\u003e\n\u003ctd\u003e4.5 Hz (270 cpm)\u003c\/td\u003e\n\u003ctd\u003eCheck the machine's vibration frequencies before selecting the sensor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDynamic operating range\u003c\/td\u003e\n\u003ctd\u003e2.54 mm (0.100 in) peak-to-peak maximum displacement\u003c\/td\u003e\n\u003ctd\u003eEnsure the expected casing motion remains within the specified limit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVelocity range\u003c\/td\u003e\n\u003ctd\u003e25 mm\/s (1 in\/s), at +22°C casing vibration, 100 Hz, and 10 kΩ load\u003c\/td\u003e\n\u003ctd\u003eThis value applies to the stated test conditions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil resistance\u003c\/td\u003e\n\u003ctd\u003e1.25 kΩ ±5%\u003c\/td\u003e\n\u003ctd\u003eUseful as one diagnostic check when following approved test procedures.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-coil inductance\u003c\/td\u003e\n\u003ctd\u003e125 mH typical\u003c\/td\u003e\n\u003ctd\u003eCompare with applicable manufacturer test procedures.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating and storage temperature\u003c\/td\u003e\n\u003ctd\u003e-29°C to +121°C (-20°F to +250°F)\u003c\/td\u003e\n\u003ctd\u003eApplies to the 9200 transducer.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity\u003c\/td\u003e\n\u003ctd\u003eUp to 95%, noncondensing\u003c\/td\u003e\n\u003ctd\u003ePrevent condensation around terminals and cable connections.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMoisture protection\u003c\/td\u003e\n\u003ctd\u003eDust and moisture resistant\u003c\/td\u003e\n\u003ctd\u003e100% relative humidity, non-submerged, when ordered with integral cable.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase and adapter material\u003c\/td\u003e\n\u003ctd\u003eAnodized A204 aluminum\u003c\/td\u003e\n\u003ctd\u003eConfirm mechanical and environmental suitability for the installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGasket material\u003c\/td\u003e\n\u003ctd\u003eNeoprene\u003c\/td\u003e\n\u003ctd\u003eInspect sealing surfaces during maintenance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e102 mm (4 in) typical\u003c\/td\u003e\n\u003ctd\u003eActual height depends on connector option.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiameter\u003c\/td\u003e\n\u003ctd\u003e41 mm (1.6 in) typical\u003c\/td\u003e\n\u003ctd\u003eAllow sufficient clearance around the mounting location.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical weight\u003c\/td\u003e\n\u003ctd\u003e300 g (10.5 oz)\u003c\/td\u003e\n\u003ctd\u003eTypical sensor weight.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e The 74712 accessory temperature range is listed separately as -29°C to +204°C (-20°F to +400°F). Do not apply that limit to the 9200 transducer itself.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e03 | Measurement Principle and Diagnostic Capability\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 9200 measures casing vibration velocity through a two-wire transducer arrangement. Its output can support vibration monitoring when the receiving equipment provides the correct load and signal interface.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration trending:\u003c\/strong\u003e Tracks changes in casing vibration velocity against an established operating baseline.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondition comparison:\u003c\/strong\u003e Helps engineers compare vibration behavior across operating loads, speeds, and maintenance periods.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAbnormal vibration investigation:\u003c\/strong\u003e Provides measurement data for investigating changes associated with imbalance, looseness, misalignment, or altered operating conditions. The sensor does not identify these faults independently.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal-chain troubleshooting:\u003c\/strong\u003e Supports checks of wiring continuity, terminal loading, mounting orientation, and receiving-channel configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe transducer is a measurement component, not a standalone diagnostic system. Fault identification requires machine context, suitable monitoring equipment, reliable baseline data, and engineering analysis.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e04 | Typical Equipment and Application Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eEquipment\u003c\/th\u003e\n\u003cth\u003ePotential monitoring use\u003c\/th\u003e\n\u003cth\u003eSelection check\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCentrifugal pumps\u003c\/td\u003e\n\u003ctd\u003eCasing vibration trending during normal operation\u003c\/td\u003e\n\u003ctd\u003eCheck the expected frequency range and mounting location.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial motors\u003c\/td\u003e\n\u003ctd\u003eComparing casing vibration before and after maintenance\u003c\/td\u003e\n\u003ctd\u003eVerify that the mounting surface and measurement direction suit the vibration being monitored.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFans and blowers\u003c\/td\u003e\n\u003ctd\u003eTracking changes in vibration velocity as operating conditions change\u003c\/td\u003e\n\u003ctd\u003eConfirm that the lowest frequency of interest exceeds the sensor's specified minimum.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressors\u003c\/td\u003e\n\u003ctd\u003eMonitoring casing vibration as part of a broader condition-monitoring system\u003c\/td\u003e\n\u003ctd\u003eConfirm the monitoring strategy, sensor position, and signal-processing compatibility.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral rotating machinery\u003c\/td\u003e\n\u003ctd\u003eProviding velocity measurements to a compatible monitoring or data-acquisition channel\u003c\/td\u003e\n\u003ctd\u003eVerify the 10 kΩ calibration load and receiving-instrument interface.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eUse this model where casing vibration velocity is the required measurement. If the application requires shaft-relative displacement, verify whether a proximity-probe system is more appropriate.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e05 | Installation and Commissioning Procedure\u003c\/strong\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm orientation:\u003c\/strong\u003e Install the transducer at its specified calibration angle to maintain the stated sensitivity tolerance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect the mounting base:\u003c\/strong\u003e Verify the circular base, M10 × 1 stud, and contact surface before tightening.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoute the cable:\u003c\/strong\u003e Check the 24 ft cable path for abrasion, heat exposure, crushing, and interference with moving parts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify the termination:\u003c\/strong\u003e Confirm the specified 10 kΩ load and the output measurement points across terminals A and B.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the measurement range:\u003c\/strong\u003e Confirm expected casing displacement and vibration frequency remain within the stated operating limits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEstablish a baseline:\u003c\/strong\u003e Record the operating state, measurement location, and initial vibration values after commissioning.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eFollow the applicable equipment manual and site isolation procedures during installation. Do not alter monitoring alarm thresholds solely to compensate for unexpected sensor readings.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e06 | Global PLC Spare HUB’s Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eFor two-wire velocity transducers, mounting orientation and electrical loading are essential parts of measurement accuracy. A mechanically secure installation can still produce misleading readings if the sensor orientation or receiving load differs from the calibration conditions.\u003c\/p\u003e\n\u003cp\u003eFor example, if a pump's reported vibration changes after sensor replacement, first confirm the mounting angle and terminal load. Then inspect the cable route, connection integrity, and measurement channel settings. Compare readings at similar operating speed and load before concluding that machine vibration has increased.\u003c\/p\u003e\n\u003cp\u003eEngineers should also distinguish casing velocity from shaft-relative displacement. These measurements describe different mechanical behavior and require different sensor arrangements. Select the transducer according to the machine's monitoring objective, not simply the available mounting space.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e07 | Model Selection Comparison\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eCompare the requested model with this alternative: \u003ca href=\"https:\/\/www.plcsparehub.com\/products\/9200-06-02-01-00-9200-bently-nevada-two-wire-sensor-probe\"\u003e\u003cstrong\u003e9200-06-02-01-00 Bently Nevada Two-Wire Sensor Probe\u003c\/strong\u003e\u003c\/a\u003e.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSelection factor\u003c\/th\u003e\n\u003cth\u003e9200-03-24-10-00\u003c\/th\u003e\n\u003cth\u003e9200-06-02-01-00\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct family\u003c\/td\u003e\n\u003ctd\u003e9200 Two-Wire Transducer\u003c\/td\u003e\n\u003ctd\u003e9200 family, based on the supplied product reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting angle \/ minimum frequency\u003c\/td\u003e\n\u003ctd\u003e90° ±2.5°; 4.5 Hz (270 cpm)\u003c\/td\u003e\n\u003ctd\u003eVerify from the official part-number documentation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable option\u003c\/td\u003e\n\u003ctd\u003e24 ft\u003c\/td\u003e\n\u003ctd\u003eVerify from the official part-number documentation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting base\u003c\/td\u003e\n\u003ctd\u003eCircular; M10 × 1 stud\u003c\/td\u003e\n\u003ctd\u003eVerify from the official part-number documentation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency approval\u003c\/td\u003e\n\u003ctd\u003e00: No approvals required\u003c\/td\u003e\n\u003ctd\u003eVerify site approval requirements and the exact configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelection recommendation\u003c\/td\u003e\n\u003ctd\u003eSuitable when the specified mounting orientation, cable reach, base, and load conditions match the installation.\u003c\/td\u003e\n\u003ctd\u003eConsider only after confirming its mounting, cable, sensitivity, and approval specifications.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical recommendation:\u003c\/strong\u003e Do not treat the two models as direct replacements based on the shared 9200 family alone. Obtain the full specifications for 9200-06-02-01-00 and compare mounting angle, minimum frequency, cable arrangement, base, and approvals. For critical monitoring channels, verify sensitivity and the 10 kΩ load requirements before returning the system to service.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e08 | Troubleshooting and Maintenance Notes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow or unexpected output:\u003c\/strong\u003e Verify the terminal load, output measurement points, wiring continuity, and receiving-channel configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReadings change after installation:\u003c\/strong\u003e Check the mounting angle and installation surface before changing alarm thresholds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnstable trends:\u003c\/strong\u003e Inspect cable connections and routing, then compare measurements under similar machine operating conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuspected coil fault:\u003c\/strong\u003e Measure resistance only with the sensor safely isolated and according to the approved procedure. Compare the result with the specified 1.25 kΩ ±5% value.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-frequency monitoring concern:\u003c\/strong\u003e Confirm that the required measurement frequency is not below the specified 4.5 Hz minimum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e09 | Warranty, Packing, and Shipping\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondition:\u003c\/strong\u003e New and original in factory packing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory warranty:\u003c\/strong\u003e 12 months, subject to the applicable purchase terms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping options:\u003c\/strong\u003e FedEx, UPS, and DHL, subject to destination and service availability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder verification:\u003c\/strong\u003e Confirm the complete model number, cable option, mounting base, and approval requirements before ordering.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e10 | Frequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1. What should I send when asking for a quotation for this transducer?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eProvide the full part number, required quantity, destination country, and application details. If replacing an installed unit, include photos of its label, mounting base, and cable termination to help verify the configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2. Can I use this sensor if my machine operates below 4.5 Hz?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe listed minimum operating frequency is 4.5 Hz. If the required measurement includes lower frequencies, consult the manufacturer documentation and select a sensor with a suitable specified frequency response.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3. Why is the calibration load important when commissioning the sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe specified sensitivity assumes a 10 kΩ load and the correct mounting orientation. A different load or installation angle may affect the measured output, so verify both before comparing readings with historical data.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4. Should I choose a velocity transducer or a proximity probe for shaft vibration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA velocity transducer measures vibration velocity associated with its mounting point, typically the machine casing. A proximity probe measures displacement relative to a suitable target, commonly a shaft. Select according to the required measurement and monitoring architecture.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5. What should I verify before replacing a sensor in a critical monitoring channel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConfirm the mounting angle, frequency range, cable length, base thread, receiving load, and approval requirements. After installation, verify signal behavior and document the new baseline before relying on the channel for condition assessment.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eRequest a Quote\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eContact \u003cstrong\u003eGlobal PLC Spare HUB\u003c\/strong\u003e with model \u003cstrong\u003e9200-03-24-10-00\u003c\/strong\u003e, the required quantity, and your installation details. We can help review the listed configuration and available shipping options before you place an order.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/920074712.png?v=1784875671\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013929033910,"sku":"9200-03-24-10-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/9200_1_89fabb21-7cae-4d62-b875-dc1c631e4333.jpg?v=1792468242","url":"https:\/\/www.plcsparehub.com\/products\/9200-03-24-10-00-bently-nevada-precision-9200-series-velocity-transducer","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}