{"product_id":"900u02-0100-honeywell-universal-input-output-module-for-safety-manager","title":"900U02-0100 Honeywell Universal Input\/Output Module for Safety Manager","description":"\u003ch3\u003e\u003cstrong\u003eHoneywell 900U02-0100 | Universal I\/O for Safety Manager Systems\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #0066cc;\"\u003eHoneywell 900U02-0100\u003c\/span\u003e\u003c\/strong\u003e is a Safety Universal Input\/Output (UIO) module for Honeywell Safety Manager systems. It combines analog input and analog output capabilities within one module.\u003c\/p\u003e\n\u003cp\u003eThe module handles 4–20 mA field signals and supports HART communication. It accepts 2-wire, 3-wire, and 4-wire current transmitters. Sink-type input transmitters are also supported.\u003c\/p\u003e\n\u003cp\u003eIts configurable I\/O architecture helps engineers allocate channels according to process requirements. The module supports up to 16 analog input channels and up to 8 analog output channels, subject to the selected configuration.\u003c\/p\u003e\n\u003cp\u003eA 10 ms update rate supports process signal acquisition and output control. Channel-level protection and module isolation provide additional electrical protection for field interfaces.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e01 | I\/O Architecture – One Module, Multiple Signal Functions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration Item\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule type\u003c\/td\u003e\n\u003ctd\u003eSafety Universal Input\/Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e900U02-0100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem family\u003c\/td\u003e\n\u003ctd\u003eSafety Manager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput signal\u003c\/td\u003e\n\u003ctd\u003e4–20 mA analog current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput signal\u003c\/td\u003e\n\u003ctd\u003e4–20 mA analog current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART communication\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum analog inputs\u003c\/td\u003e\n\u003ctd\u003e16 channels per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum analog outputs\u003c\/td\u003e\n\u003ctd\u003e8 channels per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal update rate\u003c\/td\u003e\n\u003ctd\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eNon-redundant and redundant configurations supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eChannel allocation:\u003c\/strong\u003e The supplied configuration data lists 16 channels for non-redundant UIO operation and 14 channels for redundant UIO operation. The original non-redundant entry contains a formatting error (\"161 Channels\"). Confirm the exact channel allocation and supported combinations against the Honeywell hardware manual.\u003c\/p\u003e\n\u003cp\u003eThe analog output section lists eight channels as standard, with assignment to channel positions 9–16. Do not assume that the maximum input and output counts can operate simultaneously without checking the approved channel configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e02 | Field Power and Electrical Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module provides a nominal 24 V DC field supply. Its protection architecture includes channel-level electronic short-circuit protection and internal fusing.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical Parameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eField supply voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum field voltage\u003c\/td\u003e\n\u003ctd\u003e22 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum field voltage\u003c\/td\u003e\n\u003ctd\u003e27 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum load per module\u003c\/td\u003e\n\u003ctd\u003e4.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum load per channel\u003c\/td\u003e\n\u003ctd\u003e500 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectronic short-circuit protection\u003c\/td\u003e\n\u003ctd\u003e620 mA per channel, resettable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal channel fuse\u003c\/td\u003e\n\u003ctd\u003e1 A, non-replaceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField supply fuse\u003c\/td\u003e\n\u003ctd\u003e10 A internal electronic fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule-to-rack isolation\u003c\/td\u003e\n\u003ctd\u003e1.5 kV DC, logic side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule-to-module isolation\u003c\/td\u003e\n\u003ctd\u003e1.5 kV DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eProtection distinction:\u003c\/strong\u003e The 620 mA electronic short-circuit protection and 1 A internal fuse serve different protective functions. The electronic protection is resettable. The internal fuse is not field-replaceable.\u003c\/p\u003e\n\u003cp\u003eDo not use the 10 A field supply fuse rating as the permitted module load. The stated maximum load is 4.2 A per module. Check the actual load distribution before connecting field devices.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e03 | Analog Input – Transmitter Acquisition\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe analog input section supports current transmitters in different wiring arrangements. It also supports HART communication and line monitoring.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Parameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput type\u003c\/td\u003e\n\u003ctd\u003eCurrent input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported transmitter wiring\u003c\/td\u003e\n\u003ctd\u003e2-wire, 3-wire, and 4-wire devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter type\u003c\/td\u003e\n\u003ctd\u003eSink-type input transmitters supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum input channels\u003c\/td\u003e\n\u003ctd\u003e16 per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine monitoring\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput range\u003c\/td\u003e\n\u003ctd\u003e4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCut-off limits\u003c\/td\u003e\n\u003ctd\u003e3–22 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\/D converter resolution\u003c\/td\u003e\n\u003ctd\u003e16 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance\u003c\/td\u003e\n\u003ctd\u003e250 Ω nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum input voltage\u003c\/td\u003e\n\u003ctd\u003e0–30 V, referenced to common, no damage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel-to-channel crosstalk\u003c\/td\u003e\n\u003ctd\u003e58 dB, DC to 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter field power conditioning\u003c\/td\u003e\n\u003ctd\u003eCurrent limited to 24 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput filter\u003c\/td\u003e\n\u003ctd\u003eFirst-order low-pass, 1 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eAnalog input hardware accuracy:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Condition\u003c\/th\u003e\n\u003cth\u003eNon-redundant\u003c\/th\u003e\n\u003cth\u003eRedundant\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e23.5 ± 2 °C\u003c\/td\u003e\n\u003ctd\u003e0.1% of full scale\u003c\/td\u003e\n\u003ctd\u003e0.2% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0 to +60 °C\u003c\/td\u003e\n\u003ctd\u003e0.17% of full scale\u003c\/td\u003e\n\u003ctd\u003e0.34% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eEngineering interpretation:\u003c\/strong\u003e The 16-bit A\/D resolution defines the digital conversion granularity. It does not represent the complete measurement accuracy. For loop assessment, consider transmitter accuracy, module accuracy, wiring resistance, and grounding conditions together.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e04 | Analog Output – Current Loop Control\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe output section provides 4–20 mA current-loop signals for control valves, positioners, and other compatible field devices. HART communication is supported.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Parameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput type\u003c\/td\u003e\n\u003ctd\u003e4–20 mA current loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum output channels\u003c\/td\u003e\n\u003ctd\u003e8 per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel assignment\u003c\/td\u003e\n\u003ctd\u003eAssignable as channels 9–16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine monitoring\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput accuracy at 25 °C\u003c\/td\u003e\n\u003ctd\u003eLess than 0.5% of full scale, including linearity, over the operating temperature range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundant output accuracy\u003c\/td\u003e\n\u003ctd\u003eLess than 1% of full scale, including linearity, over the operating temperature range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput ripple\u003c\/td\u003e\n\u003ctd\u003e≤125 mV peak-to-peak at power-line frequency, across 250 Ω load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput readback accuracy\u003c\/td\u003e\n\u003ctd\u003e0.17% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput current linearity\u003c\/td\u003e\n\u003ctd\u003e±0.1% of full scale, nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirectly settable output range\u003c\/td\u003e\n\u003ctd\u003e2.4–21 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum resistive load\u003c\/td\u003e\n\u003ctd\u003e250 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum resistive load\u003c\/td\u003e\n\u003ctd\u003e750 Ω, subject to confirmation against the original specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum output compliance voltage\u003c\/td\u003e\n\u003ctd\u003e14 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum open-circuit voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum load capacitance\u003c\/td\u003e\n\u003ctd\u003eLess than 1 µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eOutput load considerations:\u003c\/strong\u003e The output circuit must operate within its specified load and compliance limits. Check the field device input resistance, cable resistance, and any series-connected barriers or isolators.\u003c\/p\u003e\n\u003cp\u003eThe source data lists the maximum resistive load as \"7504 Ohms\". This page interprets it as 750 Ω, but the value should be confirmed with the official Honeywell documentation before publication.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e05 | Signal Processing and Application Considerations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess measurement:\u003c\/strong\u003e Connect compatible 4–20 mA transmitters for pressure, temperature, flow, and level measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFinal element control:\u003c\/strong\u003e Use the analog output channels for compatible current-controlled actuators and positioners.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHART instrument integration:\u003c\/strong\u003e Support compatible HART field devices for digital instrument communication.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel monitoring:\u003c\/strong\u003e Use line monitoring to assist with field-loop fault identification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant architecture:\u003c\/strong\u003e Apply the approved redundant UIO configuration where the safety system design requires it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe module combines signal acquisition and output functions. This can reduce the need for separate analog input and output modules in suitable system configurations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e06 | Commissioning Checks for Field Engineers\u003c\/strong\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm the module identity.\u003c\/strong\u003e Verify 900U02-0100 against the system bill of materials and hardware configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReview channel allocation.\u003c\/strong\u003e Confirm the input and output assignments match the approved engineering configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck transmitter wiring.\u003c\/strong\u003e Verify the 2-wire, 3-wire, or 4-wire connection method and transmitter current direction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasure field supply voltage.\u003c\/strong\u003e Check the voltage at the module and at the field device under operating load.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify current-loop loading.\u003c\/strong\u003e Include device resistance, cable resistance, and additional loop components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest input scaling.\u003c\/strong\u003e Apply known current values and compare the engineering-unit readings with the configured range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest output response.\u003c\/strong\u003e Check commanded current and measured loop current at several operating points.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReview diagnostics.\u003c\/strong\u003e Check channel status, line monitoring, and protection indications before returning the system to service.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":68112957702326,"sku":"900U02-0100","price":163.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/900U02-0100-1.jpg?v=1795162165","url":"https:\/\/www.plcsparehub.com\/products\/900u02-0100-honeywell-universal-input-output-module-for-safety-manager","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}