{"product_id":"900sp1-0100-honeywell-controledge-expansion-processor-module","title":"900SP1-0100 Honeywell ControlEdge Expansion Processor Module","description":"\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color:#c00000;\"\u003e900SP1-0100\u003c\/span\u003e Honeywell Expansion Processor Module\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#c00000;\"\u003e900SP1-0100\u003c\/span\u003e\u003c\/strong\u003e is a dedicated Expansion Processor Module for the \u003cstrong\u003e\u003cspan style=\"color:#c00000;\"\u003eHoneywell ControlEdge 900\u003c\/span\u003e\u003c\/strong\u003e platform.\u003c\/p\u003e\n\n\u003cp\u003eThe module manages communication between expansion I\/O racks and control processor modules.\u003c\/p\u003e\n\n\u003cp\u003eIt enables reliable distributed I\/O integration across industrial automation architectures.\u003c\/p\u003e\n\n\u003cp\u003eThe hardware supports high-speed Ethernet communication and flexible network topology deployment.\u003c\/p\u003e\n\n\u003cp\u003eThe design targets process-critical applications requiring stable rack-to-rack data exchange.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eCore Engineering Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color:#c00000;\"\u003e900SP1-0100\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color:#c00000;\"\u003eControlEdge 900\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Type:\u003c\/strong\u003e Expansion Processor Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain Function:\u003c\/strong\u003e Expansion I\/O communication interface\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessor:\u003c\/strong\u003e Dual Core ARM Cortex-A9\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessor Speed:\u003c\/strong\u003e 667 MHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArchitecture:\u003c\/strong\u003e 32-bit industrial embedded controller\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Addressing:\u003c\/strong\u003e Rotary address switch from 1 to 99\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus Monitoring:\u003c\/strong\u003e Dual tri-color diagnostic LEDs\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eIndustrial Communication Design\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Ports:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Type:\u003c\/strong\u003e Shielded RJ45\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePort Function:\u003c\/strong\u003e Auto-crossover communication\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransmission Speed:\u003c\/strong\u003e 10\/100BaseTx auto-detecting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Protection:\u003c\/strong\u003e 1500 VRMS for 1 minute\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurge Protection:\u003c\/strong\u003e 600W transient suppression capability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePort Diagnostics:\u003c\/strong\u003e Integrated LED indicators on each port\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Protocol:\u003c\/strong\u003e Dedicated I\/O communication\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterference Resistance:\u003c\/strong\u003e Industrial-grade EMC protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Stability:\u003c\/strong\u003e Optimized for continuous process communication\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eNetwork Topology Support\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color:#c00000;\"\u003e900SP1-0100\u003c\/span\u003e\u003c\/strong\u003e module supports multiple industrial Ethernet deployment structures.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSupports Star network topology\u003c\/li\u003e\n\u003cli\u003eSupports Ring network topology\u003c\/li\u003e\n\u003cli\u003eSupports redundant I\/O architectures\u003c\/li\u003e\n\u003cli\u003eSupports non-redundant system layouts\u003c\/li\u003e\n\u003cli\u003eSupports standard 100BaseTx industrial communication\u003c\/li\u003e\n\u003cli\u003eSupports shielded industrial Ethernet cabling\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eIndustrial Cable Distance Capability\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielded Ethernet Distance:\u003c\/strong\u003e 100 meters maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFiber Optic Distance:\u003c\/strong\u003e 5000 meters maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended Copper Cable:\u003c\/strong\u003e Shielded CAT5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended Fiber:\u003c\/strong\u003e Multi-mode duplex 62.5\/125\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFiber Connector Type:\u003c\/strong\u003e SC connector\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eRecommended Industrial Network Equipment\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eMoxa EDS-308 unmanaged Ethernet switch\u003c\/li\u003e\n\u003cli\u003eMoxa EDS-308-MM-SC industrial switch\u003c\/li\u003e\n\u003cli\u003eMoxa EDS-316-MM-SC Ethernet switch\u003c\/li\u003e\n\u003cli\u003eMoxa IMC-101-M-SC fiber converter\u003c\/li\u003e\n\u003cli\u003e24VDC-powered industrial switching equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eElectrical and Environmental Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 2.6W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat Dissipation:\u003c\/strong\u003e 2.6W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Installation:\u003c\/strong\u003e ControlEdge 900 expansion rack\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Suitability:\u003c\/strong\u003e Industrial automation environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnti-Noise Capability:\u003c\/strong\u003e High immunity against communication interference\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong-Term Stability:\u003c\/strong\u003e Designed for continuous industrial runtime\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eImproves distributed I\/O communication reliability\u003c\/li\u003e\n\u003cli\u003eSupports scalable automation system expansion\u003c\/li\u003e\n\u003cli\u003eReduces communication latency between racks\u003c\/li\u003e\n\u003cli\u003eSupports long-distance industrial fiber deployment\u003c\/li\u003e\n\u003cli\u003eSimplifies redundant network architecture implementation\u003c\/li\u003e\n\u003cli\u003eProvides stable communication in harsh electrical environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eDiagnostic Capability\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eLED indicators display communication health status\u003c\/li\u003e\n\u003cli\u003eSupports quick Ethernet port fault identification\u003c\/li\u003e\n\u003cli\u003eDetects communication interruption conditions rapidly\u003c\/li\u003e\n\u003cli\u003eImproves rack-level troubleshooting efficiency\u003c\/li\u003e\n\u003cli\u003eSupports maintenance visibility during commissioning\u003c\/li\u003e\n\u003cli\u003eHelps engineers isolate network topology issues\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eSuitable Equipment and Industrial Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eDistributed control systems\u003c\/li\u003e\n\u003cli\u003eProcess automation cabinets\u003c\/li\u003e\n\u003cli\u003eIndustrial Ethernet control networks\u003c\/li\u003e\n\u003cli\u003ePlant-wide I\/O communication systems\u003c\/li\u003e\n\u003cli\u003eOil and gas automation systems\u003c\/li\u003e\n\u003cli\u003ePower generation control platforms\u003c\/li\u003e\n\u003cli\u003eChemical processing facilities\u003c\/li\u003e\n\u003cli\u003eWater treatment automation systems\u003c\/li\u003e\n\u003cli\u003eLarge-scale PLC and DCS integration projects\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB Review\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#c00000;\"\u003e900SP1-0100\u003c\/span\u003e\u003c\/strong\u003e delivers dependable communication performance in distributed industrial control architectures.\u003c\/p\u003e\n\n\u003cp\u003eThe module performs efficiently in applications requiring stable rack-level Ethernet communication.\u003c\/p\u003e\n\n\u003cp\u003eIts dual-core processor improves data exchange responsiveness between expansion I\/O systems.\u003c\/p\u003e\n\n\u003cp\u003eIndustrial engineers value the module for flexible network topology deployment.\u003c\/p\u003e\n\n\u003cp\u003eThe integrated diagnostic indicators simplify commissioning and maintenance operations.\u003c\/p\u003e\n\n\u003cp\u003eThe module suits modern process industries requiring scalable and redundant automation infrastructure.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eInstallation Recommendations\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eInstall the module inside approved ControlEdge 900 racks\u003c\/li\u003e\n\u003cli\u003eUse shielded Ethernet cabling for communication stability\u003c\/li\u003e\n\u003cli\u003eVerify rack address settings before startup\u003c\/li\u003e\n\u003cli\u003eSeparate communication cables from high-voltage wiring\u003c\/li\u003e\n\u003cli\u003eConfirm network topology before commissioning\u003c\/li\u003e\n\u003cli\u003eUse qualified industrial Ethernet switches only\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eLogistics and Delivery Information\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eFast dispatch within 24–48 hours\u003c\/li\u003e\n\u003cli\u003eWorldwide shipping support available\u003c\/li\u003e\n\u003cli\u003eFedEx international delivery service available\u003c\/li\u003e\n\u003cli\u003eUPS industrial logistics support available\u003c\/li\u003e\n\u003cli\u003eDHL express shipping available\u003c\/li\u003e\n\u003cli\u003eProtective anti-static industrial packaging included\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eWarranty and Service Terms\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e12-month warranty included\u003c\/li\u003e\n\u003cli\u003eTechnical support during warranty coverage\u003c\/li\u003e\n\u003cli\u003ePre-shipment inspection completed before delivery\u003c\/li\u003e\n\u003cli\u003eProfessional industrial packing process applied\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eProfessional FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy does the system require an Expansion Processor Module?\u003c\/strong\u003e\n\u003cp\u003eThe module enables communication between remote expansion I\/O racks and CPM racks.\u003c\/p\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eWhen should engineers choose fiber optic communication?\u003c\/strong\u003e\n\u003cp\u003eFiber communication suits long-distance installations and high electromagnetic interference environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eWhat is the practical benefit of Ring topology?\u003c\/strong\u003e\n\u003cp\u003eRing topology improves communication redundancy during network interruption conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eHow can technicians identify communication faults quickly?\u003c\/strong\u003e\n\u003cp\u003eThe onboard diagnostic LEDs help identify Ethernet link and communication status immediately.\u003c\/p\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eWhat should buyers verify before selecting \u003cspan style=\"color:#c00000;\"\u003e900SP1-0100\u003c\/span\u003e?\u003c\/strong\u003e\n\u003cp\u003eConfirm ControlEdge 900 compatibility, rack quantity, network topology, and communication distance requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45013999091894,"sku":"900SP1-0100","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/900SP1-0100_a191f4b0-705b-4457-be66-1b6db39d72d6.jpg?v=1779787191","url":"https:\/\/www.plcsparehub.com\/products\/900sp1-0100-honeywell-controledge-expansion-processor-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}