{"product_id":"89477-80-bently-nevada-interconnect-cable-shielded-sensor-wire","title":"89477-80 Bently Nevada Interconnect Cable Shielded Sensor Wire","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eBently Nevada 89477-80\u003c\/strong\u003e\u003c\/span\u003e is a heavy-duty industrial signal cable designed specifically for vibration transducers, including velocity sensors and accelerometers. As part of the genuine \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e89477 Cable Series\u003c\/strong\u003e\u003c\/span\u003e, this assembly features a 2-conductor 18 AWG twisted-pair shielded construction. It establishes reliable low-noise signal paths between field-mounted dynamic transducers and monitoring instrumentation over long plant distances.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eConfiguration Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eDecoding the part numbering logic for \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e89477-80\u003c\/strong\u003e\u003c\/span\u003e:\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e89477\u003c\/strong\u003e\u003c\/span\u003e — Base Model: Two-Conductor Shielded Interconnect Cable Assembly\n    \u003cul\u003e\n      \u003cli\u003e\n\u003cstrong\u003e-80\u003c\/strong\u003e — Cable Length Designation: 80 Feet (approximately 24.4 Meters) total length\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eEnd A Termination\u003c\/strong\u003e — Molded 90-degree right-angle two-socket plug for tight clearance connection\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eEnd B Termination\u003c\/strong\u003e — Pre-crimped terminal lugs designed for barrier strip connection inside junction boxes\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications Matrix\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"width: 35%;\"\u003e\u003cstrong\u003eBrand \u0026amp; Manufacturer\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eBently Nevada\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eFull Part Number\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e89477-80\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e89477 Interconnect Series\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eConductor Gauge \u0026amp; Type\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e18 AWG, two-conductor tinned copper twisted pair\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eShielding Construction\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e100% coverage braid\/foil shield with integrated drain wire for EMI noise immunity\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003ePhysical Length\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e80.0 Feet \/ 24.4 Meters (Factory standard range: 2.0 ft to 99 ft)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eConnector A Interface\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eRight-angle 2-socket female connector (designed for top\/side sensor mounts)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eConnector B Interface\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eFork\/spade terminal lugs for terminal block wiring\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eJacket Material \u0026amp; Durability\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eHigh-flex elastomer insulation resistant to industrial oils, chemicals, and mechanical abrasion\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eEnvironmental Resistance\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eMoisture-resistant molded strain relief boots on sensor termination point\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cstrong\u003eVariant Comparison \u0026amp; Engineering Recommendations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSelecting the appropriate \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e89477 Cable Series\u003c\/strong\u003e\u003c\/span\u003e length is critical for maintaining signal integrity without introducing excess loop impedance or physical cable clutter:\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTarget Model:\u003c\/strong\u003e \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e89477-80\u003c\/strong\u003e\u003c\/span\u003e offers a 80-foot continuous run, ideal for direct routing from high-overhead bearing pedestals down to field marshalling cabinets without intermediate splices.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShort-Run Alternative:\u003c\/strong\u003e Compare with \u003ca href=\"https:\/\/www.plcsparehub.com\/products\/89477-17-bently-nevada-interconnect-signal-cable-17-ft\"\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e89477-17\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e. That 17-foot option is designed for close-coupled local junction box connections directly on skid assemblies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eTechnical Selection Advice:\u003c\/strong\u003e Avoid coiling excess cable lengths inside junction boxes. If your sensor sits within 15 feet of an intermediate terminal housing, select \u003ca href=\"https:\/\/www.plcsparehub.com\/products\/89477-17-bently-nevada-interconnect-signal-cable-17-ft\"\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e89477-17\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e to minimize inductive pickup. Use the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e89477-80\u003c\/strong\u003e\u003c\/span\u003e when home-running signals directly back to remote monitoring racks across large equipment decks.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTarget Applications \u0026amp; Machinery Diagnostics Support\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eConnecting velocity seismoprobes (such as 9200 series) to 3500 monitoring systems\u003c\/li\u003e\n  \u003cli\u003eInterfacing casing accelerometers on large industrial steam turbines and gearboxes\u003c\/li\u003e\n  \u003cli\u003eSignal transmission in high-noise environments near heavy variable frequency drives (VFDs)\u003c\/li\u003e\n  \u003cli\u003eContinuous dynamic signal monitoring for fast Fourier transform (FFT) vibration analysis\u003c\/li\u003e\n  \u003cli\u003ePreventing ground loop interference through floating shield configurations\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB Insights \u0026amp; Field Experience\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eIn power generation and petrochemical facilities, our field engineers frequently trace intermittent 50\/60 Hz noise spikes back to improper cable routing or damaged outer shielding on sensor leads. The \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e89477-80\u003c\/strong\u003e\u003c\/span\u003e uses heavy 18 AWG twisted conductors that reduce voltage drop over its entire 80-foot span. When installing this long cable run through rigid conduit, always verify that the right-angle plug boot remains untwisted during threading. Securing the shield drain wire exclusively at the monitoring system end prevents ground loop currents from corrupting raw vibration waveform data.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ1: What is the primary advantage of the right-angle connector on the 89477-80?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: The 90-degree plug provides low-profile clearance when sensors are installed in narrow machinery guards or tight turbine casing enclosures, preventing cable kink strain.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: Should both ends of the shield drain wire be connected to ground?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: No. Connect the shield drain wire at the rack\/monitor end only. Grounding both ends creates ground loops that introduce electrical interference into dynamic signal paths.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: Can the terminal lugs on End B be trimmed and re-stripped for screw-terminal blocks?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: Yes. Field technicians can shorten or re-terminate the terminal lug end as needed, provided proper stripping tools are used to avoid nicking the internal 18 AWG conductors.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ4: How does 18 AWG wiring perform over an 80-foot cable span compared to lighter gauge wires?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA4: The thicker 18 AWG cross-section provides lower loop resistance, minimizing signal attenuation and preserving amplitude accuracy across high frequency ranges.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ5: Is this cable rated for direct exposure to industrial lubricants and moisture?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA5: The heavy elastomer jacket is oil and moisture resistant, though liquid-tight flexible conduit is still recommended for permanent submerged or high-washdown zones.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eOrder Fulfillment, Packaging \u0026amp; Warranty Terms\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSupply Condition:\u003c\/strong\u003e Brand new, genuine original factory-sealed unit\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePackage Contents:\u003c\/strong\u003e 1x \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eBently Nevada 89477-80\u003c\/strong\u003e\u003c\/span\u003e Interconnect Cable Assembly (80 Feet)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDispatch Lead Time:\u003c\/strong\u003e Fast warehouse dispatch within 24 to 48 hours of order clearance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGlobal Delivery:\u003c\/strong\u003e Worldwide express freight options via FedEx, UPS, and DHL\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWarranty Protection:\u003c\/strong\u003e Fully covered under a comprehensive 12-month factory warranty\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013971271862,"sku":"89477-80","price":142.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/Bently89477_4.jpg?v=1784876351","url":"https:\/\/www.plcsparehub.com\/products\/89477-80-bently-nevada-interconnect-cable-shielded-sensor-wire","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}