{"product_id":"8920-ps-dc-power-supply-mtl-instruments-8000-is-module","title":"8920-PS-DC Power Supply MTL Instruments 8000 IS Module","description":"\u003ch3\u003e\u003cstrong\u003ePower Distribution \u0026amp; Redundancy Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003e8920-PS-DC\u003c\/strong\u003e engineered by \u003cstrong style=\"color: #0056b3;\"\u003eMTL Instruments\u003c\/strong\u003e within the \u003cstrong style=\"color: #0056b3;\"\u003eMTL8000\u003c\/strong\u003e distributed process I\/O platform functions as a high-reliability DC-to-DC intrinsically safe (IS) module power supply. Delivering a regulated 12 V DC output at up to 5 A capacity, this unit powers up to eight Zone 2\/1 IS I\/O modules simultaneously while supporting active load sharing for N+1 redundant system architectures.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eElectrical \u0026amp; Efficiency Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n      \u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer \u0026amp; Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cstrong style=\"color: #0056b3;\"\u003eMTL Instruments\u003c\/strong\u003e \/ \u003cstrong style=\"color: #0056b3;\"\u003eMTL8000\u003c\/strong\u003e Series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cstrong style=\"color: #0056b3;\"\u003e8920-PS-DC\u003c\/strong\u003e IS Module DC Power Supply\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal \u0026amp; Range Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 V DC nominal (18.5 to 36 V DC wide operational span)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRegulated Output Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e12 V DC ± 5% at 5 A continuous capacity (drives up to 8 IS modules)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFull-Load Conversion Efficiency\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e76% (at 18.5 V \/ 4.1 A); 78% (at 24 V \/ 3.3 A); 76.5% (at 36 V \/ 2.1 A)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eGalvanic \u0026amp; Safety Isolation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e250 V AC rms input-to-output isolation (1500 V AC rms dielectric test); voltage clamped output (Un = 18 V)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRedundancy Capability\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSupports parallel load sharing for fault-tolerant power distribution\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Termination\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDuplicated 2-part screw terminals accepting up to 2.5 mm² conductors\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cstrong\u003eHazardous Area Approvals \u0026amp; Compliance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInstallation Zone Rating:\u003c\/strong\u003e Approved for Safe Area, Class I, Division 2 (Groups A, B, C, D), and Zone 2, IIC T4 hazardous locations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntrinsic Safety Standards:\u003c\/strong\u003e Complies with \u003cstrong style=\"color: #0056b3;\"\u003eFM Class 3610 \/ 3611\u003c\/strong\u003e, \u003cstrong style=\"color: #0056b3;\"\u003eEN 50020:1994\u003c\/strong\u003e (Intrinsic Safety \"i\"), and \u003cstrong style=\"color: #0056b3;\"\u003eATEX Directive 94\/9\/EC\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEMC \u0026amp; Electrical Safety:\u003c\/strong\u003e Tested to \u003cstrong style=\"color: #0056b3;\"\u003eEN 50081-2\u003c\/strong\u003e, \u003cstrong style=\"color: #0056b3;\"\u003eEN 50082-2\u003c\/strong\u003e, \u003cstrong style=\"color: #0056b3;\"\u003eEN 61000-3-2\/3\u003c\/strong\u003e, \u003cstrong style=\"color: #0056b3;\"\u003eEN 61010-1\u003c\/strong\u003e, and \u003cstrong style=\"color: #0056b3;\"\u003eEN 61131-2\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eMechanical \u0026amp; Environmental Resilience\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCarrier Mounting Interface:\u003c\/strong\u003e Mounts directly onto \u003cstrong style=\"color: #0056b3;\"\u003e8724-CA-PS\u003c\/strong\u003e power supply carriers; dimensions 84 (W) × 110 (H) × 160 (D) mm; weight 1290 g.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThermal Operating Envelope:\u003c\/strong\u003e -40 °C to +55 °C at full load (optimum orientation); -40 °C to +50 °C (worst-case orientation); up to +70 °C at 60% load without forced cooling.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStorage \u0026amp; Humidity:\u003c\/strong\u003e -40 °C to +85 °C storage range; 5% to 95% non-condensing relative humidity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMechanical Shock \u0026amp; Vibration:\u003c\/strong\u003e 2 g vibration (10–100 Hz per BS EN 60068-2-6) and 10 g shock (11 ms pulse per BS EN 60068-2-27).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCorrosion \u0026amp; Reliability:\u003c\/strong\u003e ISA SP71.04 Level G3 corrosive atmosphere tolerance inside suitable enclosures; IP20 ingress protection; 80,000 hours MTBF at 50 °C external ambient.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eInstallation \u0026amp; Commissioning Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCarrier Alignment:\u003c\/strong\u003e Seat the \u003cstrong style=\"color: #0056b3;\"\u003e8920-PS-DC\u003c\/strong\u003e firmly onto the \u003cstrong style=\"color: #0056b3;\"\u003e8724-CA-PS\u003c\/strong\u003e carrier backplane and verify all supply connectors lock mechanically to maintain IP20 rating.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDuplicated Bus Wiring:\u003c\/strong\u003e Utilize the duplicated 2-part screw terminals (max 2.5 mm² wire) to daisy-chain 24 V DC bulk power cleanly across adjacent carriers without external terminal blocks.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOrientation Planning:\u003c\/strong\u003e Mount carriers in the manufacturer-specified optimum orientation to preserve the full +55 °C continuous full-load thermal rating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 × \u003cstrong style=\"color: #0056b3;\"\u003eMTL Instruments 8920-PS-DC\u003c\/strong\u003e IS Module DC Power Supply\u003c\/li\u003e\n  \u003cli\u003e1 × Duplicated 2-Part Input Screw Terminal Connector Set\u003c\/li\u003e\n  \u003cli\u003e1 × Hazardous Area Control Drawing \u0026amp; Safety Instruction Sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eEngineering FAQ \u0026amp; Field Troubleshooting\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ1: How does carrier mounting orientation impact maximum allowable cabinet ambient temperature?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA1:\u003c\/strong\u003e Mounting the \u003cstrong style=\"color: #0056b3;\"\u003e8724-CA-PS\u003c\/strong\u003e carrier in its optimum vertical airflow orientation allows full 5 A load operation up to +55 °C. Horizontal or restricted-airflow orientations derate the continuous full-load ceiling to +50 °C due to natural convection limits.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: What happens if a single power supply fails in a dual-redundant load-sharing configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e Because the \u003cstrong style=\"color: #0056b3;\"\u003e8920-PS-DC\u003c\/strong\u003e incorporates active load-sharing circuitry, the surviving parallel unit seamlessly assumes 100% of the 12 V DC bus load (up to 8 IS modules) without voltage dip or process I\/O interruption.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: Why is the 12 V DC output voltage clamped at Un = 18 V?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e Intrinsic safety barrier certification (\u003cstrong style=\"color: #0056b3;\"\u003eEN 50020\u003c\/strong\u003e \/ \u003cstrong style=\"color: #0056b3;\"\u003eFM 3610\u003c\/strong\u003e) mandates infallible crowbar\/zener voltage clamping so fault transients never inject incendive energy levels into downstream Zone 1 or Division 1 field circuits.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ4: Can this power supply operate reliably from unregulated 24 V DC battery backup banks?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA4:\u003c\/strong\u003e Yes. Its wide 18.5 V to 36 V DC input window accommodates deep battery discharge states as well as float-charging voltage spikes while holding output regulation within ±5%.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ5: What preventive maintenance checks preserve the 80,000-hour MTBF rating in harsh chemical plants?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA5:\u003c\/strong\u003e Inspect cabinet door seals regularly to maintain ISA G3 corrosive gas protection, verify screw terminal torque on the 2.5 mm² DC input lines annually, and keep convection vents free of conductive dust accumulation.\u003c\/p\u003e","brand":"MTL","offers":[{"title":"Default Title","offer_id":68094359699638,"sku":"8920-PS-DC","price":101.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/8920-PS-DC-1.jpg?v=1794989359","url":"https:\/\/www.plcsparehub.com\/products\/8920-ps-dc-power-supply-mtl-instruments-8000-is-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}