{"product_id":"8750-ca-ns-ge-fanuc-pac8000-controller-carrier-base-module","title":"8750-CA-NS GE Fanuc PAC8000 Controller Carrier Base Module","description":"\u003ch3\u003e\u003cb\u003eSystem Architecture \u0026amp; Platform Overview\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cfont color=\"#0056b3\"\u003e\u003cb\u003e8750-CA-NS\u003c\/b\u003e\u003c\/font\u003e engineered by \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eGE Fanuc\u003c\/b\u003e\u003c\/font\u003e functions as a robust controller carrier designed specifically for the \u003cfont color=\"#0056b3\"\u003e\u003cb\u003ePAC8000\u003c\/b\u003e\u003c\/font\u003e modular automation ecosystem. Control system architects deploy this specialized base carrier to mount dual controller or EBIM modules alongside dedicated power supply monitors in hazardous process environments.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cb\u003eCarrier Mounting \u0026amp; Compatible Modules\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003e\u003cb\u003eMounting Category\u003c\/b\u003e\u003c\/th\u003e\n      \u003cth\u003e\u003cb\u003eSupported Hardware \/ Component\u003c\/b\u003e\u003c\/th\u003e\n      \u003cth\u003e\u003cb\u003eDesign Part Number\u003c\/b\u003e\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eController \/ EBIM Sockets\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003eDual processor or Ethernet\/Bus Interface Module slots\u003c\/td\u003e\n      \u003ctd\u003e\u003cfont color=\"#0056b3\"\u003e\u003cb\u003e8521-XX-XX\u003c\/b\u003e\u003c\/font\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003ePower Supply Monitor\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003eDedicated power health monitoring module slot\u003c\/td\u003e\n      \u003ctd\u003e\u003cfont color=\"#0056b3\"\u003e\u003cb\u003e8410-NS-PS\u003c\/b\u003e\u003c\/font\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cb\u003eMultidimensional Technical Specifications Matrix\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003e\u003cb\u003eEngineering Domain\u003c\/b\u003e\u003c\/th\u003e\n      \u003cth\u003e\u003cb\u003eParameter Subsystem\u003c\/b\u003e\u003c\/th\u003e\n      \u003cth\u003e\u003cb\u003eTechnical Specification Metric\u003c\/b\u003e\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eBrand \u0026amp; Series\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003eManufacturer \u0026amp; Platform Line\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cfont color=\"#0056b3\"\u003e\u003cb\u003eGE Fanuc\u003c\/b\u003e\u003c\/font\u003e \/ \u003cfont color=\"#0056b3\"\u003e\u003cb\u003ePAC8000\u003c\/b\u003e\u003c\/font\u003e Series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eModule Identification\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003ePart Number \u0026amp; Carrier Type\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cfont color=\"#0056b3\"\u003e\u003cb\u003e8750-CA-NS\u003c\/b\u003e\u003c\/font\u003e (Controller Carrier Base)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eHazardous Approvals\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003eZone \u0026amp; Division Ratings\u003c\/td\u003e\n      \u003ctd\u003eZone 2 IIC T6 \/ Class 1 Div 2 Groups A-D (FM, CSA, ATEX Type n)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eElectrical Interface\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003eConnectors \u0026amp; Terminals\u003c\/td\u003e\n      \u003ctd\u003eMale Railbus out, Dual 9-pin D-type serial ports, 7 power screw terminal pairs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eDC Power Architecture\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003eExternal Power \u0026amp; Top Bus\u003c\/td\u003e\n      \u003ctd\u003e12.0 V DC ($\\pm 5\\%$) via 6-pin top connector for expansion modules\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003ePhysical Dimensions\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003eFootprint \u0026amp; Overall Height\u003c\/td\u003e\n      \u003ctd\u003e200 x 253 mm footprint, 55 mm overall height, approx. 1.43 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eEnvironmental Range\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003eOperating Temp \u0026amp; Humidity\u003c\/td\u003e\n      \u003ctd\u003e$-40\\ \\text{°C}$ to $+70\\ \\text{°C}$, 5 to 95% RH non-condensing\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cb\u003eInstallation \u0026amp; Power Distribution Guidelines\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cb\u003eFlat Panel Mounting:\u003c\/b\u003e Secure the \u003cfont color=\"#0056b3\"\u003e\u003cb\u003e8750-CA-NS\u003c\/b\u003e\u003c\/font\u003e carrier firmly to control cabinet backplanes using the four designated M4 mounting fixings.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eTop Power Feed Connection:\u003c\/b\u003e Apply clean 12.0 V DC power to the 6-pin connector located at the top of the carrier to energize connected expansion modules.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eGrounding Compliance:\u003c\/b\u003e Fasten grounding leads directly to the dual M4 screw terminals to maintain electromagnetic shielding integrity in industrial plants.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eSystem Compliance \u0026amp; Certifications\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cb\u003eExplosion Protection:\u003c\/b\u003e Fully certified under Factory Mutual (Class 3611), CSA C22.2 No. 213, and ATEX EN50021 standards for hazardous gas atmospheres.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eRugged ZINTEC Construction:\u003c\/b\u003e Built using painted 1.6 mm ZINTEC steel conforming to BS EN 10152 alongside an epoxy resin glass laminate PCB.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eStandard Package Contents\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cb\u003eCore Hardware:\u003c\/b\u003e 1 x \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eGE Fanuc 8750-CA-NS\u003c\/b\u003e\u003c\/font\u003e PAC8000 Controller Carrier\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eMounting Hardware:\u003c\/b\u003e Integrated M4 ground terminals and backplane fixing provisions\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eEngineering Application \u0026amp; Selection Insights\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eSpecify the \u003cfont color=\"#0056b3\"\u003e\u003cb\u003e8750-CA-NS\u003c\/b\u003e\u003c\/font\u003e carrier when constructing distributed \u003cfont color=\"#0056b3\"\u003e\u003cb\u003ePAC8000\u003c\/b\u003e\u003c\/font\u003e nodes in hazardous process zones requiring redundant controller capabilities. Always verify that external 12V DC power supplies maintain strict $\\pm 5\\%$ regulation to prevent bus reset events across linked carriers.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cb\u003eExpert Frequently Asked Questions (FAQ)\u003c\/b\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cb\u003eQ1: Does the 6-pin top connector on the 8750-CA-NS supply power directly to the main controllers?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA1: No, the 12V DC top connection powers the power supply monitor and secondary modules on linked carriers, whereas controllers draw power through internal backplane paths.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eQ2: What specific hazardous area certifications validate this carrier for Zone 2 installation?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA2: The module complies with ATEX Category 3 (EN50021 type 'n'), Factory Mutual Class 3611, and CSA C22.2 No. 213 for Class 1 Division 2 locations.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eQ3: How many serial communication ports are built directly into the carrier base?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA3: The carrier provides two standard 9-pin D-type female serial communication ports for local device integration and diagnostics.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eQ4: What material composition provides corrosion resistance in harsh industrial facilities?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA4: The chassis is constructed from painted 1.6 mm ZINTEC steel manufactured to BS EN 10152 specifications, paired with an epoxy glass laminate board.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eQ5: What preventive checks are recommended if power health monitoring circuits report voltage drops?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA5: Inspect the 7 pairs of power screw terminals and verify that external 12V DC supplies do not drift outside the $\\pm 5\\%$ voltage tolerance window.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":68094371725494,"sku":"8750-CA-NS","price":114.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/8750-CA-NS-1.jpg?v=1794989424","url":"https:\/\/www.plcsparehub.com\/products\/8750-ca-ns-ge-fanuc-pac8000-controller-carrier-base-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}