{"product_id":"8710-ca-04-ge-fanuc-pac8000-4-module-carrier-railbus-base","title":"8710-CA-04 GE Fanuc PAC8000 4-Module Carrier Railbus Base","description":"\u003ch3\u003e\u003cb\u003e\u003cspan style=\"color: #003366;\"\u003ePAC8000 System Architecture \u0026amp; Carrier Design\u003c\/span\u003e\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cb\u003e\u003cspan style=\"color: #003366;\"\u003e8710-CA-04\u003c\/span\u003e\u003c\/b\u003e functions as a rugged 4-module carrier engineered for the \u003cb\u003e\u003cspan style=\"color: #003366;\"\u003eGE Fanuc PAC8000 I\/O\u003c\/span\u003e\u003c\/b\u003e platform. Built from modified polyphenylene oxide molding with an integrated epoxy resin glass laminate printed wiring board, this carrier supports up to four general-purpose I\/O modules and field terminals while managing a 32-slot address bus. It distributes internal DC power, routes bussed field power, and carries critical control signals and data streams across the high-speed Railbus backplane.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e\u003cspan style=\"color: #003366;\"\u003eCore Specifications \u0026amp; Engineering Matrix\u003c\/span\u003e\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse: collapse; width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cb\u003eParameter Classification\u003c\/b\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cb\u003eTechnical Specification Details\u003c\/b\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eManufacturer \u0026amp; Series\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003e\u003cspan style=\"color: #003366;\"\u003eGE Fanuc\u003c\/span\u003e\u003c\/b\u003e | \u003cb\u003e\u003cspan style=\"color: #003366;\"\u003ePAC8000 I\/O\u003c\/span\u003e\u003c\/b\u003e Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eModel Number \u0026amp; Type\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: \u003cb\u003e\u003cspan style=\"color: #003366;\"\u003e8710-CA-04\u003c\/span\u003e\u003c\/b\u003e (4-Module DIN\/Panel Carrier)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eModule Capacity\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eAccepts up to four general-purpose I\/O modules and corresponding field terminals.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eAddress Bus Range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e32-slot address bus capability with individual module address range spanning 1–32.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eRailbus Interconnects\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eEquipped with female-in and male-out Railbus connectors for daisy-chain data distribution.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eBussed Field Power Supply\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional 8-pin connector situated at the top rear routes external supplies through specific I\/O modules to power field instruments.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eEarthing \u0026amp; Shield Protection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated isolated earthing bar designed for secure cable screen and shield termination.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePhysical Dimensions \u0026amp; Weight\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e178 mm (Width) × 170 mm (Depth) × 22 mm (Height); Net weight: 350 g.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cb\u003e\u003cspan style=\"color: #003366;\"\u003eHazardous Area \u0026amp; Environmental Compliance\u003c\/span\u003e\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eNode Classification:\u003c\/b\u003e Approved for Class 1, Div 2, Groups A, B, C, D T4 and Zone 2, IIC T4 hazardous operating locations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eField Wiring Location:\u003c\/b\u003e Certified for installation matching the primary node hazardous area classification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eThermal Operating Envelope:\u003c\/b\u003e Continuous operation rated from –40°C to +70°C; storage temperature range from –40°C to +85°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eHumidity Tolerance:\u003c\/b\u003e Supports 5% to 95% relative humidity under non-condensing operating conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMechanical Resilience:\u003c\/b\u003e Built to withstand industrial vibration and shock profiles as defined in system specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003e\u003cspan style=\"color: #003366;\"\u003eMechanical Mounting Guidelines\u003c\/span\u003e\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eMounting Flexibility:\u003c\/b\u003e Supports flat panel screw mounting or snap-on DIN-rail installation inside control enclosures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCompatible Rail Profiles:\u003c\/b\u003e Accepts standard 'top hat' 35 x 7.5 mm or 35 x 15 mm rails (EN 50022) as well as G-section rails (EN 50035).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003e\u003cspan style=\"color: #003366;\"\u003eFrequently Asked Questions (FAQ)\u003c\/span\u003e\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eQ: How does the 8710-CA-04 carrier distribute power to connected field instrumentation?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: An 8-pin connector located at the top rear of the carrier accepts external power supplies, routing them through specific I\/O modules to energize field loops without separate marshalling strips.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ: Can this 4-module carrier be installed directly into Class 1 Div 2 hazardous locations?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, the unit carries official certification for Class 1, Div 2, Groups A, B, C, D T4 and Zone 2, IIC T4 hazardous areas when deployed within a compliant system architecture.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ: What is the primary function of the isolated earthing bar on the carrier housing?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: The isolated earthing bar provides a dedicated mechanical and electrical tie-point for cable screens and shields, effectively mitigating electromagnetic interference in industrial environments.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ: Which DIN-rail standards are supported by the mechanical mounting brackets?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: The enclosure accommodates standard 35 mm 'top hat' rails conforming to EN 50022 and G-section rails conforming to EN 50035, alongside direct flat panel mounting.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ: How do connected modules interface with the 32-slot address bus architecture?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Each module slot maps into a designated segment of the 32-slot address range (1–32), transmitting control signals and diagnostic data deterministically over the integrated Railbus backplane.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e\u003cspan style=\"color: #003366;\"\u003eProcurement \u0026amp; System Integration Guidance\u003c\/span\u003e\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eWhen expanding your \u003cb\u003e\u003cspan style=\"color: #003366;\"\u003ePAC8000 I\/O\u003c\/span\u003e\u003c\/b\u003e architecture with the \u003cb\u003e\u003cspan style=\"color: #003366;\"\u003e8710-CA-04\u003c\/span\u003e\u003c\/b\u003e carrier, verify your cabinet DIN-rail profile and ensure bussed field power connections match your loop voltage requirements. Contact our engineering sales team today to request a formal quotation, verify live factory inventory, and secure rapid logistics delivery for your automation project.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/8710-CA-04.png?v=1794989750\" alt=\"\"\u003e\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":68094458429622,"sku":"8710-CA-04","price":119.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/8710-CA-04-3.jpg?v=1794989750","url":"https:\/\/www.plcsparehub.com\/products\/8710-ca-04-ge-fanuc-pac8000-4-module-carrier-railbus-base","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}