{"product_id":"84661-15-interconnect-cables-bently-nevada-armored-lead","title":"84661-15 Interconnect Cables Bently Nevada Armored Lead","description":"\u003ch3\u003e\u003cb\u003eEngineering Overview \u0026amp; Configuration Breakdown\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e84661-15\u003c\/span\u003e\u003c\/strong\u003e from \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eBently Nevada\u003c\/span\u003e\u003c\/strong\u003e represents an industrial-grade interconnect cable assembly engineered for vibration monitoring architectures.\u003cbr\u003eThis product configuration follows a structured taxonomy for mechanical protection and signal integrity:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Model\u003c\/strong\u003e: \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e84661\u003c\/span\u003e\u003c\/strong\u003e - Standard interconnect extension cable series.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength Suffix (-15)\u003c\/strong\u003e: Denotes an exact factory-assembled length of 15 feet (4.57 meters).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Architecture\u003c\/strong\u003e: Two-conductor twisted, shielded 22 AWG layout.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Shielding\u003c\/strong\u003e: Integrated flexible metallic armor for severe industrial environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTermination Design A\u003c\/strong\u003e: Two-socket moisture-resistant female connector on the probe interface side.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTermination Design B\u003c\/strong\u003e: Robust terminal lugs on the monitoring hardware connection side.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eTechnical Specifications Matrix\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse: collapse; width: 100%;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter Category\u003c\/th\u003e\n\u003cth\u003eTechnical Metric\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eBently Nevada\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e84661-15\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Category\u003c\/td\u003e\n\u003ctd\u003eInterconnect Extension and Lead Assemblies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Construction\u003c\/td\u003e\n\u003ctd\u003e2-conductor twisted, shielded 22 AWG with outer armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Length Option\u003c\/td\u003e\n\u003ctd\u003e15 feet (approx. 4.57 meters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength Boundaries\u003c\/td\u003e\n\u003ctd\u003eMinimum: 3.0 ft (0.9 m) \/ Maximum: 96 ft (29 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Interface (End 1)\u003c\/td\u003e\n\u003ctd\u003eMoisture-resistant, two-socket female connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Interface (End 2)\u003c\/td\u003e\n\u003ctd\u003eIndustrial-grade terminal lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cb\u003eGlobal PLC Spare HUB Insight \u0026amp; Field Experience\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eField instrumentation technicians frequently select the \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e84661-15\u003c\/span\u003e\u003c\/strong\u003e when routing signals from hazardous turbine decks to local junction boxes.\u003cbr\u003eOur engineering deployments show that the external metallic armor protects internal 22 AWG conductors from physical crushing during heavy plant maintenance.\u003cbr\u003eUsing moisture-resistant female connectors successfully prevents condensation-induced signal grounding in outdoor gas turbine enclosures.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eTarget Machinery and Diagnostic Capabilities\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThis interconnect cable is optimized for integration with eddy current transducer systems monitoring:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHeavy-duty industrial steam and gas turbines\u003c\/li\u003e\n\u003cli\u003eCentrifugal and axial compressors in petrochemical plants\u003c\/li\u003e\n\u003cli\u003eLarge multi-stage boiler feed water pumps\u003c\/li\u003e\n\u003cli\u003eCritical hydro-electric generator bearings\u003c\/li\u003e\n\u003cli\u003eReal-time shaft radial vibration and axial position telemetry diagnostics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eWarranty, Logistics, and Fulfillment\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eGlobal PLC Spare HUB\u003c\/span\u003e\u003c\/strong\u003e backs the \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e84661-15\u003c\/span\u003e\u003c\/strong\u003e with a comprehensive 12-month quality warranty.\u003cbr\u003eExpedited global logistics are handled through trusted express couriers including FedEx, UPS, and DHL.\u003cbr\u003eStandard orders are processed, securely packaged, and dispatched within 24 to 48 hours to minimize industrial downtime.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eModel Comparison and Selection Guide\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eEvaluate alternative length variants within the same product family:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e84661-15\u003c\/span\u003e\u003c\/strong\u003e: Factory configuration featuring a 15-foot physical span.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.plcsparehub.com\/products\/84661-17-interconnect-cables-bently-nevada-armored-lead-assembly\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e84661-17\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e: Alternative configuration featuring a 17-foot physical span.\u003c\/li\u003e\n\u003cli\u003e\n\u003cem\u003eSelection Advice\u003c\/em\u003e: Always measure exact cable tray routing paths from the probe housing to the monitor rack before choosing length suffixes, ensuring total loop capacitance remains within system manufacturer specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eFrequently Asked Questions (FAQ)\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion\u003c\/strong\u003e: What is the primary function of the metallic armor on the \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e84661-15\u003c\/span\u003e\u003c\/strong\u003e cable?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnswer\u003c\/strong\u003e: The outer armor provides mechanical protection against abrasion, crushing, and cutting hazards present in harsh turbine operating environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion\u003c\/strong\u003e: Can I cut or splice the \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e84661-15\u003c\/span\u003e\u003c\/strong\u003e cable in the field if it is too long?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnswer\u003c\/strong\u003e: Field modification of eddy current extension cables alters total loop resistance and capacitance, which negatively impacts calibration accuracy; always order the exact pre-fabricated length required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion\u003c\/strong\u003e: How does the moisture-resistant connector prevent false vibration trips?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnswer\u003c\/strong\u003e: It forms a tight environmental seal over the pin connection, stopping humidity and oil mist from creating leakage currents that distort high-frequency vibration signals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion\u003c\/strong\u003e: What is the recommended procedure for securing the terminal lugs at End 2?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnswer\u003c\/strong\u003e: Ensure terminal screws are torqued to specified rack manufacturer values and verify shield continuity to ground to maintain electromagnetic interference rejection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion\u003c\/strong\u003e: How should I determine whether to use the \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e84661-15\u003c\/span\u003e\u003c\/strong\u003e or a longer variant like the \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e84661-17\u003c\/span\u003e\u003c\/strong\u003e?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnswer\u003c\/strong\u003e: Map out the physical cable tray route allowing for slack loops; if a 15-foot run leaves the terminal ends taut, step up to the 17-foot option to avoid mechanical tension on the connector pins.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013971009718,"sku":"84661-15","price":135.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/84661Bently_1.jpg?v=1791603813","url":"https:\/\/www.plcsparehub.com\/products\/84661-15-interconnect-cables-bently-nevada-armored-lead","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}