{"product_id":"65uv5-1004qd-fireye-uv-flame-scanner-industrial-burner-sensor","title":"65UV5-1004QD Fireye UV Flame Scanner Industrial Burner Sensor","description":"\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color:#c0392b;\"\u003e65UV5-1004QD\u003c\/span\u003e | Fireye Integrated UV Flame Scanner Platform\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#c0392b;\"\u003eFireye 65UV5-1004QD\u003c\/span\u003e\u003c\/strong\u003e delivers stable ultraviolet flame supervision for industrial combustion systems.\u003c\/p\u003e\n\n\u003cp\u003eThe scanner combines UV sensing, relay outputs, analog monitoring, and fault diagnostics inside one compact industrial enclosure.\u003c\/p\u003e\n\n\u003cp\u003eIts rugged construction supports continuous operation in harsh furnace environments.\u003c\/p\u003e\n\n\u003cp\u003eThe quick-disconnect structure simplifies installation and maintenance procedures.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDesigned for engineers requiring dependable flame discrimination and fast burner shutdown response.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eEngineering Highlights\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eIntegrated UV flame scanner architecture\u003c\/li\u003e\n\u003cli\u003eFast 4-second flame failure response\u003c\/li\u003e\n\u003cli\u003e4-20mA flame signal output standard\u003c\/li\u003e\n\u003cli\u003eSPDT flame relay output\u003c\/li\u003e\n\u003cli\u003eNEMA 4X and IP66 environmental protection\u003c\/li\u003e\n\u003cli\u003eIndustrial cast aluminum housing\u003c\/li\u003e\n\u003cli\u003eQuick-disconnect electrical connection\u003c\/li\u003e\n\u003cli\u003eSupports hazardous industrial locations\u003c\/li\u003e\n\u003cli\u003eOptimized for burner management systems\u003c\/li\u003e\n\u003cli\u003eContinuous flame strength monitoring capability\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eCore Technical Data\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Fireye\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cspan style=\"color:#c0392b;\"\u003e\u003cstrong\u003e65UV5-1004QD\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e UV flame scanner\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetection Principle:\u003c\/strong\u003e Ultraviolet flame sensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e 24 Vdc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 3.8 Watts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Tolerance:\u003c\/strong\u003e +20% \/ -25%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlame Failure Response:\u003c\/strong\u003e 4 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog Signal:\u003c\/strong\u003e 4-20mA DC output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Analog Load:\u003c\/strong\u003e 750 Ohms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Connector:\u003c\/strong\u003e 8-pin quick disconnect\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlame Relay:\u003c\/strong\u003e SPDT (N.O.\/N.C.)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFault Relay:\u003c\/strong\u003e SPST (N.O.)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Contact Rating:\u003c\/strong\u003e 2A @ 240Vac\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing Material:\u003c\/strong\u003e Cast aluminum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurface Finish:\u003c\/strong\u003e Black polyester powder coat\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Rating:\u003c\/strong\u003e NEMA 4X \/ IP66\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to +65°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Range:\u003c\/strong\u003e 0% to 95% non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Style:\u003c\/strong\u003e 1\" NPT female pipe mount\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Air Connection:\u003c\/strong\u003e 3\/4\" NPT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e Approx. 2.5 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Classification:\u003c\/strong\u003e Class I Div 2 \/ Ex II 3 G\/D\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eSystem Construction Logic\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan style=\"color:#c0392b;\"\u003eOptical Detection Module\u003c\/span\u003e\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eDetects UV radiation generated by combustion flame\u003c\/li\u003e\n\u003cli\u003eImproves flame recognition stability in bright furnaces\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan style=\"color:#c0392b;\"\u003eSignal Processing Layer\u003c\/span\u003e\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eProcesses flame intensity and stability conditions\u003c\/li\u003e\n\u003cli\u003eProvides isolated analog feedback to control systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan style=\"color:#c0392b;\"\u003eProtection \u0026amp; Relay Section\u003c\/span\u003e\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eControls flame relay and fault relay operation\u003c\/li\u003e\n\u003cli\u003eSupports burner trip logic integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan style=\"color:#c0392b;\"\u003eDiagnostic Interface\u003c\/span\u003e\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eLED indicators display flame and fault conditions\u003c\/li\u003e\n\u003cli\u003eSupports rapid troubleshooting during commissioning\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eMechanical \u0026amp; Environmental Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eHeavy-duty aluminum enclosure improves durability\u003c\/li\u003e\n\u003cli\u003ePowder-coated surface resists industrial corrosion\u003c\/li\u003e\n\u003cli\u003eIP66 structure protects against water and dust ingress\u003c\/li\u003e\n\u003cli\u003eDesigned for demanding combustion plant environments\u003c\/li\u003e\n\u003cli\u003eSuitable for outdoor burner installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003ePurge Air Engineering Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eUse clean and dry cooling air supply\u003c\/li\u003e\n\u003cli\u003eStandard airflow requirement: 4 SCFM\u003c\/li\u003e\n\u003cli\u003eDust-intensive combustion may require 15 SCFM\u003c\/li\u003e\n\u003cli\u003eCooling pressure must exceed furnace pressure\u003c\/li\u003e\n\u003cli\u003eProper purge air extends optical stability\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#c0392b;\"\u003e65UV5-1004QD\u003c\/span\u003e\u003c\/strong\u003e fits industrial combustion systems requiring stable flame verification with minimal false triggering.\u003c\/p\u003e\n\n\u003cp\u003eThe isolated 4-20mA output supports combustion trend monitoring and predictive diagnostics.\u003c\/p\u003e\n\n\u003cp\u003eThe quick-disconnect design reduces maintenance downtime during burner inspections.\u003c\/p\u003e\n\n\u003cp\u003eThe scanner performs effectively in applications with fluctuating thermal radiation conditions.\u003c\/p\u003e\n\n\u003cp\u003eIts environmental protection ratings support long-term operation in heavy industrial facilities.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eRecommended Equipment Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eIndustrial boilers\u003c\/li\u003e\n\u003cli\u003eGas-fired burners\u003c\/li\u003e\n\u003cli\u003eOil combustion systems\u003c\/li\u003e\n\u003cli\u003eThermal processing furnaces\u003c\/li\u003e\n\u003cli\u003ePetrochemical heaters\u003c\/li\u003e\n\u003cli\u003eSteam generation units\u003c\/li\u003e\n\u003cli\u003eIndustrial ovens and kilns\u003c\/li\u003e\n\u003cli\u003eCombustion safety management systems\u003c\/li\u003e\n\u003cli\u003eBurner management controllers\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eDiagnostic Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eContinuous flame signal analysis\u003c\/li\u003e\n\u003cli\u003eWeak flame condition monitoring\u003c\/li\u003e\n\u003cli\u003eFlame instability detection\u003c\/li\u003e\n\u003cli\u003eRelay fault indication\u003c\/li\u003e\n\u003cli\u003eBurner startup verification\u003c\/li\u003e\n\u003cli\u003eFlame presence confirmation\u003c\/li\u003e\n\u003cli\u003eCombustion trend monitoring through analog output\u003c\/li\u003e\n\u003cli\u003eSignal integrity verification during commissioning\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eCable \u0026amp; Wiring Information\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eRecommended cable: Fireye 59-598-xx\u003c\/li\u003e\n\u003cli\u003e8-conductor shielded cable configuration\u003c\/li\u003e\n\u003cli\u003e#18 AWG color-coded wiring\u003c\/li\u003e\n\u003cli\u003ePLTC-ER industrial cable rating\u003c\/li\u003e\n\u003cli\u003eUV-resistant and oil-resistant jacket available\u003c\/li\u003e\n\u003cli\u003eMaximum cable diameter: 12.2 mm\u003c\/li\u003e\n\u003cli\u003eOperating temperature up to 105°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eIndustrial Certification\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eFM approved quick-disconnect configuration\u003c\/li\u003e\n\u003cli\u003eRoHS compliant cable specification\u003c\/li\u003e\n\u003cli\u003eHazardous location certified structure\u003c\/li\u003e\n\u003cli\u003eSuitable for industrial combustion safety systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eShipping \u0026amp; Service Support\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eWorldwide shipment available\u003c\/li\u003e\n\u003cli\u003eFedEx, DHL, and UPS express delivery supported\u003c\/li\u003e\n\u003cli\u003eDispatch within 24-48 hours\u003c\/li\u003e\n\u003cli\u003eProtective export packaging included\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eWarranty Information\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e12-month warranty support\u003c\/li\u003e\n\u003cli\u003ePre-shipment inspection available\u003c\/li\u003e\n\u003cli\u003eTechnical support during operation period\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eProfessional FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy does purge airflow matter for UV scanners?\u003c\/strong\u003e\n\u003cp\u003eProper airflow prevents contamination buildup on the optical sensing window.\u003c\/p\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eHow should engineers position the scanner sight pipe?\u003c\/strong\u003e\n\u003cp\u003ePosition the scanner toward the stable flame root while avoiding refractory reflections.\u003c\/p\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eWhat advantage does the 4-20mA output provide?\u003c\/strong\u003e\n\u003cp\u003eThe analog signal supports flame trend analysis and combustion stability monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eWhen should users select the quick-disconnect version?\u003c\/strong\u003e\n\u003cp\u003eChoose quick-disconnect models when maintenance access and replacement speed are important.\u003c\/p\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cstrong\u003eWhat should buyers confirm before ordering?\u003c\/strong\u003e\n\u003cp\u003eVerify mounting thread standard, hazardous area requirements, relay compatibility, and cable type.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fireye","offers":[{"title":"Default Title","offer_id":45126461948086,"sku":"65UV5-1004QD","price":210.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/65UV5-1004QD.jpg?v=1778829313","url":"https:\/\/www.plcsparehub.com\/products\/65uv5-1004qd-fireye-uv-flame-scanner-industrial-burner-sensor","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}