{"product_id":"631a13tbeh3-mks-instruments-631a-series-precision-vacuum-sensor","title":"631A13TBEH3 MKS Instruments 631A Series Precision Vacuum Sensor","description":"\u003ch3\u003e\u003cstrong\u003eMKS Instruments 631A13TBEH3 Baratron Heated Pressure Transducer\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e631A13TBEH3\u003c\/strong\u003e is an MKS Instruments Baratron® 631A Series heated capacitance manometer. It measures absolute pressure in vacuum systems that require stable, repeatable process monitoring. Its heated sensor design helps reduce condensation and material buildup when process gases contact the sensing chamber.\u003c\/p\u003e\n\u003cp\u003eThis model provides a \u003cstrong\u003e1,000 Torr full-scale range\u003c\/strong\u003e and a stated accuracy of \u003cstrong\u003e±0.25% of reading\u003c\/strong\u003e. It uses a linear 0–10 VDC analog output and requires ±15 VDC power. These characteristics make it suitable for semiconductor process equipment and other controlled vacuum applications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e1. Model Identification and Configuration Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe complete ordering code identifies the sensor family, pressure range, material configuration, accuracy class, and heater-related option. The available model information supports the following breakdown:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode Segment\u003c\/th\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003eTechnical Interpretation\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e631A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProduct series\u003c\/td\u003e\n\u003ctd\u003eMKS Baratron 631A Series heated absolute capacitance manometer.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e13T\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePressure range\u003c\/td\u003e\n\u003ctd\u003e1,000 Torr full scale, approximately 133.3 kPa.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWetted-material configuration\u003c\/td\u003e\n\u003ctd\u003eThe supplied configuration information identifies Inconel® construction for the sensing chamber and diaphragm.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccuracy option\u003c\/td\u003e\n\u003ctd\u003e±0.25% of reading, as specified in the supplied product information.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eH3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHeater-related option\u003c\/td\u003e\n\u003ctd\u003eHeater temperature and interface configuration code. Confirm the exact factory definition before replacement or ordering.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration verification:\u003c\/strong\u003e The H3 suffix may identify an equipment-specific heater or interface configuration. Do not assume a specific setpoint, connector pinout, or mechanical interface from the suffix alone. Verify these details against the equipment BOM or the applicable MKS configuration record.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e2. Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eMKS Instruments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eBaratron®\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e631A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e631A13TBEH3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eHeated absolute capacitance manometer \/ pressure transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull-Scale Pressure\u003c\/td\u003e\n\u003ctd\u003e1,000 Torr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproximate Pressure Equivalent\u003c\/td\u003e\n\u003ctd\u003e133.3 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.25% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e0–10 VDC, linear analog output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e±15 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensing Construction\u003c\/td\u003e\n\u003ctd\u003eInconel® wetted construction, according to the supplied configuration information\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverpressure Rating\u003c\/td\u003e\n\u003ctd\u003e45 psia, as stated in the supplied product information\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Configuration\u003c\/td\u003e\n\u003ctd\u003eH3 option; exact temperature and interface require confirmation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003e3. Measurement Principle and Process Value\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Baratron capacitance manometer measures pressure through changes in capacitance. Pressure acts on a thin sensing diaphragm and changes its position relative to a reference electrode. The resulting capacitance variation is converted into an electrical signal.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAbsolute pressure measurement:\u003c\/strong\u003e The sensor references an internal vacuum cavity rather than relying on atmospheric pressure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas-independent measurement:\u003c\/strong\u003e Capacitance measurement responds to mechanical pressure on the diaphragm. It does not depend on gas thermal conductivity or ionization behavior.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog process integration:\u003c\/strong\u003e The 0–10 VDC output provides a continuous signal for compatible process controllers and pressure monitoring systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeated sensor operation:\u003c\/strong\u003e Temperature control helps limit condensation and deposits from process gases on internal sensing surfaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor applications involving condensable or reactive process gases, the heated configuration can help maintain measurement stability. However, actual compatibility depends on gas chemistry, temperature, pressure, and the complete wetted-material specification.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e4. Typical Equipment Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCVD equipment:\u003c\/strong\u003e Monitors chamber pressure during deposition processes where stable pressure feedback supports recipe control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEtching systems:\u003c\/strong\u003e Supplies pressure feedback for vacuum control and process repeatability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSemiconductor vacuum platforms:\u003c\/strong\u003e Supports pressure monitoring in process chambers and associated vacuum assemblies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-purity gas processes:\u003c\/strong\u003e Provides absolute pressure measurement where gas-independent sensing is important.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial vacuum systems:\u003c\/strong\u003e Supports process monitoring where a heated sensing element helps reduce condensation-related measurement problems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e5. Installation and Commissioning Considerations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eCorrect installation protects the sensing diaphragm and helps the instrument deliver reliable pressure feedback. Confirm the following points before placing the transducer into service.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify mechanical compatibility:\u003c\/strong\u003e Check the mounting interface, sealing arrangement, and available installation clearance against the equipment drawing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck process-gas compatibility:\u003c\/strong\u003e Confirm that the process chemistry is suitable for the specified wetted materials. Do not rely on the alloy name alone for compatibility approval.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm heater requirements:\u003c\/strong\u003e Verify the H3 temperature setting, power requirements, and connector arrangement before connecting the sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck electrical supply:\u003c\/strong\u003e Provide the specified ±15 VDC supply and confirm polarity and wiring against the applicable pinout.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValidate the analog interface:\u003c\/strong\u003e Confirm that the receiving controller accepts a 0–10 VDC signal and uses the correct pressure scaling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAllow thermal stabilization:\u003c\/strong\u003e Follow the equipment and manufacturer procedures before evaluating measurement accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the pressure response:\u003c\/strong\u003e Compare the sensor output with a suitable reference instrument during commissioning.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eNever apply process pressure beyond the specified overpressure limit. Also avoid mechanical shock, contamination, or unapproved cleaning methods that could affect the sensing diaphragm.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e6. Selection and Replacement Guidance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWhen replacing a 631A-series pressure transducer, matching the full-scale range alone is not sufficient. Engineering teams should compare the complete configuration before approving a substitute.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure range:\u003c\/strong\u003e Confirm the 1,000 Torr full-scale range and the operating pressure window of the process.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e Check that the replacement meets the required accuracy specification across the actual operating range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeater configuration:\u003c\/strong\u003e Match the heater setpoint and control arrangement. A different thermal configuration may affect process compatibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWetted materials:\u003c\/strong\u003e Verify the diaphragm and chamber materials against the process-gas specification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical interface:\u003c\/strong\u003e Confirm supply voltage, output scaling, connector type, and pin assignment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical fit:\u003c\/strong\u003e Check mounting dimensions and sealing details before installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor equipment-specific configurations such as H3, use the complete part number and the original equipment documentation during procurement. This reduces the risk of receiving a sensor with a similar range but an incompatible heater or connection arrangement.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e7. Maintenance and Fault Diagnosis\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eObserved Condition\u003c\/th\u003e\n\u003cth\u003ePossible Check\u003c\/th\u003e\n\u003cth\u003eRecommended Action\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure reading drifts after startup\u003c\/td\u003e\n\u003ctd\u003eThermal stabilization and heater operation\u003c\/td\u003e\n\u003ctd\u003eConfirm the heater reaches its specified operating condition before evaluating the reading.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController reading differs from the reference gauge\u003c\/td\u003e\n\u003ctd\u003eOutput scaling and analog input configuration\u003c\/td\u003e\n\u003ctd\u003eCheck the 0–10 VDC conversion and controller engineering-unit settings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading changes after process maintenance\u003c\/td\u003e\n\u003ctd\u003ePossible contamination or process residue\u003c\/td\u003e\n\u003ctd\u003eInspect the installation and review the process-gas exposure history.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput remains fixed or becomes unstable\u003c\/td\u003e\n\u003ctd\u003ePower supply, wiring, and signal input\u003c\/td\u003e\n\u003ctd\u003eVerify the ±15 VDC supply and signal connections before condemning the sensor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eDo not open the sealed sensing assembly or attempt field adjustment without an approved service procedure. Record the sensor output, reference pressure, heater status, and process conditions during troubleshooting. These measurements help separate sensor faults from wiring or controller problems.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e8. Supply, Warranty and Shipping\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct:\u003c\/strong\u003e MKS Instruments 631A13TBEH3 Baratron heated pressure transducer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12-month warranty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping methods:\u003c\/strong\u003e FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder verification:\u003c\/strong\u003e Please provide the complete model number and equipment requirements when requesting a quotation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTechnical confirmation:\u003c\/strong\u003e Heater temperature, connector details, and equipment-specific configuration should be checked before order confirmation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e9. Frequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What information should an engineer record before removing an installed pressure transducer?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecord the complete part number, wiring arrangement, controller scaling, heater behavior, and pressure reading under known process conditions. Photographs of the mounting interface and connector can also help prevent replacement errors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: How can a team determine whether an unstable reading comes from the sensor or the control system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCompare the transducer output with an independent reference gauge while monitoring the controller input. If the analog output remains stable but the displayed value changes, investigate the input channel, grounding, wiring, and scaling first.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Should a replacement sensor be selected only by matching its 1,000 Torr range?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. A matching range does not guarantee interchangeability. Engineers should also compare the heater configuration, accuracy class, wetted materials, output signal, supply requirements, connector, and mechanical interface.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What should procurement request when the H3 suffix is not fully documented?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRequest the original equipment configuration record or a manufacturer confirmation of the heater setpoint, connector interface, and any equipment-specific options. This step is especially important when replacing a sensor in a qualified semiconductor process tool.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: When should a pressure transducer be replaced instead of recalibrated or further investigated?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConsider replacement when the sensor cannot maintain its specified performance after external power, wiring, thermal, and controller issues have been ruled out. Before making the decision, review calibration history, process exposure, output stability, and the availability of an approved service procedure.\u003c\/p\u003e","brand":"MKS Instruments","offers":[{"title":"Default Title","offer_id":68142252753078,"sku":"631A13TBEH3","price":196.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/631D11T8FHBB-1_781da4d1-a5fc-4902-8bfb-ee36d2a07bff.jpg?v=1795504617","url":"https:\/\/www.plcsparehub.com\/products\/631a13tbeh3-mks-instruments-631a-series-precision-vacuum-sensor","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}