{"product_id":"628h13tde1b-mks-instruments-600-series-precision-absolute-transducer","title":"628H13TDE1B MKS Instruments 600 Series Precision Absolute Transducer","description":"\n\u003ch3\u003e\u003cstrong\u003eMKS Instruments 628H13TDE1B | 100°C Heated Baratron Absolute Pressure Transducer\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #1565C0;\"\u003eMKS Instruments 628H13TDE1B\u003c\/span\u003e\u003c\/strong\u003e is a heated capacitance manometer from the \u003cstrong\u003e\u003cspan style=\"color: #1565C0;\"\u003e628H Series\u003c\/span\u003e\u003c\/strong\u003e within the MKS 600 Series.\u003c\/p\u003e\n\n\u003cp\u003eThis model measures absolute pressure across a 1000 Torr full-scale range. Its internal sensor maintains a controlled temperature of 100°C. The heated architecture supports demanding semiconductor and vacuum process environments.\u003c\/p\u003e\n\n\u003cp\u003eThe instrument combines a 0.25% reading accuracy specification with 0.001% full-scale resolution. Its analog output provides a 0 to +10 VDC pressure signal. A 15-pin D-sub connector supports electrical integration with compatible monitoring equipment.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003e628H13TDE1B\u003c\/strong\u003e also features vertical calibration and Inconel wetted construction. Its compact housing supports integration into semiconductor process equipment and vacuum measurement assemblies.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e01 | Instrument Specification at a Glance\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMKS Instruments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e628H13TDE1B\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e628H Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Family\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHeated Baratron Absolute Pressure Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Principle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCapacitance Manometer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAbsolute Pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull-Scale Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 Torr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration Orientation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to +10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcess Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNW16 ISO-KF, subject to model-code verification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWetted Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInconel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cstrong\u003e02 | Measurement Performance \u0026amp; Resolution\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe 628H series supports multiple pressure ranges and measurement configurations. The specified 1000 Torr version provides the following performance characteristics.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull-Scale Range\u003c\/td\u003e\n\u003ctd\u003e1000 Torr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.25% of Reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy Components\u003c\/td\u003e\n\u003ctd\u003eNon-linearity, hysteresis, and non-repeatability included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001% FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquivalent Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 Torr at 1000 Torr FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarm-Up Time\u003c\/td\u003e\n\u003ctd\u003e2 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Position\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eMeasurement Accuracy:\u003c\/strong\u003e The ±0.25% reading specification includes non-linearity, hysteresis, and non-repeatability. It applies to the 1–25,000 Torr range configurations.\u003c\/p\u003e\n\n\u003cp\u003eAt a 1000 Torr full-scale range, 0.001% FS resolution corresponds to 0.01 Torr. Resolution and accuracy represent different measurement characteristics.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e03 | 628H Series: Available Pressure Range Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe 628H family covers a broad pressure range for different vacuum and process measurement requirements.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eRange Group\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eAvailable Full-Scale Ranges\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUltra-Low Pressure\u003c\/td\u003e\n\u003ctd\u003e0.05, 0.1, 0.25 Torr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Pressure\u003c\/td\u003e\n\u003ctd\u003e1, 2, 10, 20 Torr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedium Pressure\u003c\/td\u003e\n\u003ctd\u003e100, 1000 Torr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Pressure\u003c\/td\u003e\n\u003ctd\u003e2000, 5000, 10000 Torr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtended Pressure\u003c\/td\u003e\n\u003ctd\u003e15000, 20000, 25000 Torr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eRange-Dependent Performance:\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1–25,000 Torr:\u003c\/strong\u003e Accuracy is 0.25% of reading.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0.25, 0.1, and 0.05 Torr:\u003c\/strong\u003e Accuracy is 0.50% of reading.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0.05 Torr Range:\u003c\/strong\u003e Resolution is 0.002% FS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOther Listed Ranges:\u003c\/strong\u003e Resolution is 0.001% FS.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe 628H13TDE1B specifically uses the 1000 Torr configuration. Do not apply the lowest-range specifications to this model.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e04 | Model Suffix \u0026amp; Configuration Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe complete model number identifies the instrument family, pressure range, connection, accuracy class, calibration configuration, and electrical connector.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCode Segment\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eEngineering Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e628H\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003e100°C heated absolute Baratron pressure transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e13T\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePressure Range\u003c\/td\u003e\n\u003ctd\u003e1000 Torr full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFitting Code\u003c\/td\u003e\n\u003ctd\u003eSupplied code description indicates 8 VCR female\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccuracy Class\u003c\/td\u003e\n\u003ctd\u003e±0.25% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eStandard configuration with vertical calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrical Connector\u003c\/td\u003e\n\u003ctd\u003e15-pin D-sub with thread locks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eComplete Model:\u003c\/strong\u003e \u003cspan style=\"color: #1565C0;\"\u003e\u003cstrong\u003e628H13TDE1B\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eConfiguration Verification:\u003c\/strong\u003e The supplied model description contains a fitting discrepancy. The product specification lists NW16 ISO-KF, while the supplied suffix explanation assigns code D to 8 VCR female. Confirm the actual factory configuration before ordering or connecting the instrument.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e05 | Thermal Management \u0026amp; Temperature Compensation\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe internal heating system maintains the sensing element at 100°C. This controlled thermal environment supports measurement stability under changing process conditions.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControlled Sensor Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15–50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarm-Up Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 hours for ranges from 1 to 25,000 Torr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarm-Up Below 1 Torr\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZero Temperature Coefficient\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.002% FS\/°C for 1–25,000 Torr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZero Coefficient, 0.1 and 0.25 Torr\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01% FS\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZero Coefficient, 0.05 Torr\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.02% FS\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpan Temperature Coefficient\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.02% of Reading\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eTemperature compensation values depend on the selected pressure range. The 1000 Torr configuration uses the 0.002% FS\/°C zero coefficient.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e06 | Electrical Connection \u0026amp; Signal Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±15 VDC ±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to +10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreater than 10 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15-pin D-sub\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Locking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThread-locking screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntegrated Relay Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure Signal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalog voltage output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eThe instrument provides an analog pressure signal without integrated relay trip points. Connect it to a compatible analog input module.\u003c\/p\u003e\n\n\u003cp\u003eCheck the receiving input impedance before commissioning. The load must exceed 10 kΩ for the specified output condition.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e07 | Optional Indicators \u0026amp; Semiconductor Switches\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe 628H product family offers optional status indicators and semiconductor switch functions. These options are separate from the standard configuration described for the \u003cstrong\u003e628H13TDE1B\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOptional Function\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOperation\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Status\u003c\/td\u003e\n\u003ctd\u003eSwitch turns ON when the instrument reaches operating temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature LED\u003c\/td\u003e\n\u003ctd\u003eGreen when the sensor reaches temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeater Status\u003c\/td\u003e\n\u003ctd\u003eSwitch turns OFF when heater failure occurs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeater LED\u003c\/td\u003e\n\u003ctd\u003eGreen during normal operation; blinking red during heater failure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Switch Current\u003c\/td\u003e\n\u003ctd\u003e120 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum ON Resistance\u003c\/td\u003e\n\u003ctd\u003e20 Ω at 120 mA and 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Open-Circuit Voltage\u003c\/td\u003e\n\u003ctd\u003e28 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eThe supplied \u003cstrong\u003e628H13TDE1B\u003c\/strong\u003e configuration specifies no heater status LED. Confirm optional switches and indicators separately when the application requires external status monitoring.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e08 | Process Connection \u0026amp; Mechanical Construction\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWetted Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInconel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.3 cc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecified Fitting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNW16 ISO-KF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlternative Fitting Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/2-inch OD tube, 8 VCR female, 8 VCO female, NW25 KF, 1.33-inch OD CF, 2.75-inch OD CF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBody Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.15 in (80.0 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBody Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.87 in (98.4 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStem Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.38 in (35.1 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eThe Inconel wetted construction supports demanding process gas measurement environments. The compact housing simplifies installation in space-constrained equipment.\u003c\/p\u003e\n\n\u003cp\u003eEvaluate fitting geometry before selecting replacement hardware. NW16 ISO-KF and 8 VCR connections require different mating components.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e09 | Pressure Limits \u0026amp; Mechanical Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverpressure Limit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 psia (310 kPa) or 120% FS, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull-Scale Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 Torr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.3 cc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eThe overpressure specification defines a protection limit, not a normal operating target. Avoid pressure spikes beyond the specified limit.\u003c\/p\u003e\n\n\u003cp\u003eFor a 1000 Torr configuration, the stated 45 psia threshold exceeds 120% of full scale. Design pressure protection around the applicable manufacturer rating.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e10 | Installation \u0026amp; Commissioning Recommendations\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eMechanical Preparation\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003col\u003e\n\u003cli\u003eVerify the 1000 Torr full-scale configuration.\u003c\/li\u003e\n\u003cli\u003eConfirm vertical calibration requirements.\u003c\/li\u003e\n\u003cli\u003eCheck the actual fitting against the installation drawing.\u003c\/li\u003e\n\u003cli\u003eInspect the sealing surfaces and vacuum connection.\u003c\/li\u003e\n\u003cli\u003eConfirm process gas compatibility with Inconel.\u003c\/li\u003e\n\u003cli\u003eAllow sufficient clearance around the heated body.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003cp\u003e\u003cstrong\u003eElectrical Preparation\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003col\u003e\n\u003cli\u003eProvide a regulated ±15 VDC power supply.\u003c\/li\u003e\n\u003cli\u003eVerify the voltage polarity and ±5% tolerance.\u003c\/li\u003e\n\u003cli\u003eSecure the 15-pin D-sub connector.\u003c\/li\u003e\n\u003cli\u003eConnect the analog output to a compatible voltage input.\u003c\/li\u003e\n\u003cli\u003eCheck the receiving impedance above 10 kΩ.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003cp\u003e\u003cstrong\u003eStartup and Calibration Checks\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003col\u003e\n\u003cli\u003ePower the instrument and allow two hours for warm-up.\u003c\/li\u003e\n\u003cli\u003eMaintain stable ambient conditions within 15–50°C.\u003c\/li\u003e\n\u003cli\u003eVerify the vertical installation orientation.\u003c\/li\u003e\n\u003cli\u003eCheck zero output under suitable reference conditions.\u003c\/li\u003e\n\u003cli\u003eCompare pressure readings against a calibrated reference.\u003c\/li\u003e\n\u003cli\u003eRecord baseline readings for future maintenance comparisons.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003e\u003cstrong\u003e11 | Maintenance \u0026amp; Application Troubleshooting\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero Shift:\u003c\/strong\u003e Check thermal stabilization, mounting orientation, and reference pressure conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Saturation:\u003c\/strong\u003e Verify actual pressure and analog input scaling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlow Startup:\u003c\/strong\u003e Allow the specified warm-up period before evaluating measurement performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVacuum Leakage:\u003c\/strong\u003e Inspect the KF or VCR mating surfaces and sealing components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnexpected Pressure Changes:\u003c\/strong\u003e Check chamber pressure behavior and process-line isolation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eUse a traceable pressure reference during calibration verification. Avoid changing the instrument's calibration without approved service procedures.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e12 | Typical Industrial \u0026amp; Semiconductor Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSemiconductor Process Chambers:\u003c\/strong\u003e Absolute pressure monitoring in controlled manufacturing environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVacuum Systems:\u003c\/strong\u003e Pressure measurement in vacuum equipment and process lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThin-Film Processing:\u003c\/strong\u003e Pressure feedback for deposition equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Processing:\u003c\/strong\u003e Pressure monitoring in elevated-temperature manufacturing systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Delivery Equipment:\u003c\/strong\u003e Pressure measurement in compatible gas distribution assemblies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe 100°C heated sensor design supports applications requiring controlled sensing temperature. Engineers should verify gas compatibility, pressure limits, and fitting configuration before installation.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e13 | Compliance \u0026amp; Package Verification\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCE compliant according to the supplied product specification.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 × MKS Instruments 628H13TDE1B Heated Baratron Pressure Transducer.\u003c\/li\u003e\n\u003cli\u003eProduct identification and model information.\u003c\/li\u003e\n\u003cli\u003eApplicable technical documentation, subject to order confirmation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eConfirm cables, mounting accessories, connection adapters, and optional indicators separately. Do not assume optional accessories are included in the standard package.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e14 | Professional FAQ: Engineering Selection \u0026amp; Field Application\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ1: Why does vertical calibration matter when installing this pressure transducer?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eCalibration orientation defines the instrument's specified reference position. A different mounting position may introduce measurement deviations. Maintain the vertical orientation unless the manufacturer approves another configuration.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: How should engineers interpret the overpressure protection specification?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe instrument uses the greater value between 45 psia and 120% of full scale. This rating does not authorize continuous operation at the protection limit. Use suitable pressure regulation and isolation devices.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: Is the 628H13TDE1B suitable for applications requiring pressure alarm relays?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe specified configuration provides analog output only. It has no integrated relay trip points. Use an external pressure controller or PLC to implement alarm thresholds and interlocks.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ4: When should buyers select a 1000 Torr range instead of a 100 Torr range?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eReview the maximum expected chamber pressure and normal operating window. A 100 Torr range provides a smaller full-scale measurement span. A 1000 Torr range accommodates higher pressure conditions. Select a range that balances measurement requirements and process operating limits.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ5: What should maintenance engineers record during periodic performance checks?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eRecord zero readings, reference pressure comparisons, ambient temperature, and startup time. Also document the supply voltage and analog output condition. Historical measurements help identify gradual drift and installation-related problems.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB | Industrial Instrumentation Supply\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eGlobal PLC Spare HUB supports industrial automation and semiconductor equipment sourcing. Our team assists with product identification and configuration verification.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e12-Month Warranty:\u003c\/strong\u003e Coverage according to confirmed sales terms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTechnical Assistance:\u003c\/strong\u003e Support with model identification and interface verification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternational Shipping:\u003c\/strong\u003e FedEx, UPS, and DHL options.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch Arrangement:\u003c\/strong\u003e Typically 24–48 hours, subject to stock confirmation and order processing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eRequest a Quote for MKS 628H13TDE1B\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eLooking for the \u003cstrong\u003eMKS Instruments 628H13TDE1B\u003c\/strong\u003e? Contact Global PLC Spare HUB with your required quantity and installation details. Our team can assist with technical verification and quotation arrangements.\u003c\/p\u003e\n","brand":"MKS Instruments","offers":[{"title":"Default Title","offer_id":68020095877302,"sku":"628H13TDE1B","price":115.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/628H13TDE1B.jpg?v=1794208448","url":"https:\/\/www.plcsparehub.com\/products\/628h13tde1b-mks-instruments-600-series-precision-absolute-transducer","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}