{"product_id":"626d13tbe-mks-instruments-capacitance-manometer-pressure-sensor","title":"626D13TBE MKS Instruments Capacitance Manometer Pressure Sensor","description":"\u003ch3\u003eGlobal PLC Spare HUB's Insight: Engineering Evaluation\u003c\/h3\u003e\n\u003cp\u003eTechnical specialists at \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eGlobal PLC Spare HUB\u003c\/strong\u003e\u003c\/span\u003e evaluate the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e626D13TBE\u003c\/strong\u003e\u003c\/span\u003e as an exceptional unheated absolute pressure transducer. Manufactured by \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eMKS Instruments\u003c\/strong\u003e\u003c\/span\u003e within their renowned \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e626D\u003c\/strong\u003e\u003c\/span\u003e Baratron series, this 1000 Torr manometer features high-purity 316 stainless steel wetted surfaces to resist aggressive process gases. Field experience confirms its stable 0 to 10 VDC analog output and 15-pin D-sub architecture ensure seamless integration into semiconductor processing and vacuum chamber control loops.\u003c\/p\u003e\n\u003ch3\u003eConfiguration Breakdown (Model Suffix Architecture)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e626D\u003c\/strong\u003e\u003c\/span\u003e — Base Unheated Capacitance Manometer Platform\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e13T\u003c\/strong\u003e — Full Scale Pressure Range: 1000 Torr (1.33 bar) full scale capacity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eB\u003c\/strong\u003e — Process Fitting Type: 8 VCR Female (8-Cajon VCR swivel nut style fitting)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eE\u003c\/strong\u003e — Calibration \u0026amp; Output Suffix: Standard analog configuration with 15-pin Sub-D connector\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications Matrix\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eMKS Instruments\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number \u0026amp; Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e626D13TBE\u003c\/strong\u003e\u003c\/span\u003e \/ \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e626D\u003c\/strong\u003e\u003c\/span\u003e Baratron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAbsolute Capacitance Manometer (Diaphragm deflection sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Scale Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 Torr (compatible with Pa, Torr, and mbar units)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.25% of reading (accuracy range spanning 0.05% to 1%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Power Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±15 VDC (±5%) at 35 mA current draw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Signal Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 10 VDC linear proportional output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15-pin Sub-D Male miniature plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWetted Materials\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e316 Stainless Steel exposed vacuum components\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermal Operating Limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperating: 50.0 °C (122 °F); Storage: 80.0 °C (176 °F); Bakeout: ≤50.0 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting \u0026amp; Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAny orientation recommended; CE \u0026amp; RoHS compliant; Integrated electronics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation \u0026amp; Mechanical Setup Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e626D13TBE\u003c\/strong\u003e\u003c\/span\u003e directly to a clean 8 VCR male process port using a new nickel gasket to prevent virtual leaks. Although the sensor operates in any orientation, vertical mounting with the port facing downward helps prevent particulate accumulation on the sensing diaphragm. Connect the shielded 15-pin D-sub cable securely, ensuring the outer shield is tied to earth ground to eliminate electromagnetic interference.\u003c\/p\u003e\n\u003ch3\u003eEquipment Compatibility \u0026amp; Industrial Applications\u003c\/h3\u003e\n\u003cp\u003eEngineers deploy this Baratron manometer across critical vacuum manufacturing systems:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSemiconductor plasma etch, chemical vapor deposition (CVD), and sputtering chambers.\u003c\/li\u003e\n\u003cli\u003eVacuum furnace systems and high-precision vacuum coating deposition units.\u003c\/li\u003e\n\u003cli\u003eAnalytical instrumentation, mass spectrometers, and industrial leak detection rigs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFault Diagnostic \u0026amp; Pressure Monitoring Capabilities\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e626D13TBE\u003c\/strong\u003e\u003c\/span\u003e delivers real-time analog voltage telemetry that maps directly to absolute chamber pressure. Monitoring the zero-pressure baseline voltage (nominally 0.00 VDC at deep vacuum) allows technicians to detect thermal zero drift, diaphragm contamination, or mechanical overpressure distortion before process batch failure occurs.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Express Worldwide Logistics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 × \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eMKS Instruments\u003c\/strong\u003e\u003c\/span\u003e \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e626D13TBE\u003c\/strong\u003e\u003c\/span\u003e 1000 Torr Manometer Unit\u003c\/li\u003e\n\u003cli\u003eFactory Calibration Sheet and Safety Documentation\u003c\/li\u003e\n\u003cli\u003eShipping Lead Time: Dispatched globally within 24 to 48 hours of order confirmation.\u003c\/li\u003e\n\u003cli\u003eExpress Carriers: Secure door-to-door delivery via FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003eWarranty Protection: Backed by Global PLC Spare HUB's comprehensive 12-month warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProfessional FAQ \u0026amp; Selection Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why is an unheated manometer like the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e626D13TBE\u003c\/strong\u003e\u003c\/span\u003e preferred in certain vacuum processes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Unheated manometers do not require external AC line power for thermal jackets, making them ideal for temperature-sensitive chambers, low-power remote racks, and applications where process gas byproducts do not condense at 50 °C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How can I perform a zero-adjustment on the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e626D13TBE\u003c\/strong\u003e\u003c\/span\u003e in the field?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Pump the vacuum system down to a pressure level well below the sensor's resolution (typically \u0026lt; 10\u003cscp\u003e-4\u003c\/scp\u003e Torr using a secondary high-vacuum gauge) and adjust the front zero potentiometer until the output reads exactly 0.00 VDC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What causes sudden zero offset shifts in capacitance manometers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Sudden zero shifts are typically caused by thermal shock, mechanical stress on the VCR fitting during tightening, or particulate contamination lodging between the reference cavity and sensing diaphragm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e626D13TBE\u003c\/strong\u003e\u003c\/span\u003e withstand corrosive halogen gases used in etching?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The wetted 316 stainless steel diaphragm handles standard inert and many reactive gases, but highly corrosive fluorine or chlorine chemistries may require specialized Inconel-wetted Baratron models for long-term reliability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do I select the proper full-scale range when replacing an older vacuum gauge?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Always choose a full scale matching your maximum operating working pressure rather than absolute peak vacuum limits to maximize measurement resolution and accuracy within your active control window.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/626D.png?v=1793609219\" alt=\"\"\u003e\u003c\/p\u003e","brand":"MKS Instruments","offers":[{"title":"Default Title","offer_id":67980402196662,"sku":"626D13TBE","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/626D13TBE-1.jpg?v=1793609064","url":"https:\/\/www.plcsparehub.com\/products\/626d13tbe-mks-instruments-capacitance-manometer-pressure-sensor","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}