{"product_id":"51202329-600-honeywell-experion-pks-header-cable","title":"51202329-600 Honeywell Experion PKS Header Cable","description":"\u003ch3\u003e\u003cb\u003eProduct Identification \u0026amp; Engineering Overview\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #1565c0;\"\u003e51202329-600\u003c\/span\u003e\u003c\/strong\u003e is a Honeywell Experion PKS Series C I\/O Link Header Cable. It provides a passive communication connection for C300 Controller IOTA installations.\u003c\/p\u003e\n\u003cp\u003eThis gray pre-terminated cable features \u003cstrong\u003ethree connection drops\u003c\/strong\u003e. It distributes the Series C I\/O Link horizontally across the top of a cabinet. The assembly can span multiple Control Connection Assemblies (CCAs) and connect with additional header or extension cables.\u003c\/p\u003e\n\u003cp\u003eThe cable carries the \u003cstrong\u003e750 KBaud Series C I\/O Link\u003c\/strong\u003e. Its yellow identification label marks it as Cable A. It supports the IOL1A or IOL2A connection path.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e51202329-600\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Family\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExperion PKS Series C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComponent Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePre-terminated I\/O Link Header Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIdentification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCable A – Yellow Label\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Color\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGray\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 Drops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 KBaud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC300 Controller IOTA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cb\u003e01 | Physical Architecture \u0026amp; Cable Identification\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe cable assembly distributes the I\/O Link across Series C cabinet hardware. Its three-drop structure supports multiple IOTA connections within the approved cabinet topology.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Construction:\u003c\/strong\u003e Passive, pre-terminated assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrop Configuration:\u003c\/strong\u003e Three connection points.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRouting Direction:\u003c\/strong\u003e Horizontal distribution across the cabinet top.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabinet Coverage:\u003c\/strong\u003e Supports multiple CCAs within a cabinet side or sides.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Expansion:\u003c\/strong\u003e Can connect with additional header and extension cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Method:\u003c\/strong\u003e Interfaces with IOTA and IOTA drop connectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eActive Electronics:\u003c\/strong\u003e None.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIdentification Reference:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIdentification Item\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable A\u003c\/td\u003e\n\u003ctd\u003eYellow identification label\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable B\u003c\/td\u003e\n\u003ctd\u003eGreen identification label\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIOL1\u003c\/td\u003e\n\u003ctd\u003eGray cable identification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIOL2\u003c\/td\u003e\n\u003ctd\u003eViolet cable identification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIOL1A \/ IOL2A\u003c\/td\u003e\n\u003ctd\u003eCable A connection symbols\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIOL1B \/ IOL2B\u003c\/td\u003e\n\u003ctd\u003eCable B connection symbols\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e The gray jacket identifies the IOL1 cable family. The yellow label identifies Cable A. These are separate identification details.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e02 | Communication Performance \u0026amp; Capacity\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Series C I\/O Link provides the communication path between the C300 controller and distributed IOTA\/IOM hardware.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLink Type\u003c\/td\u003e\n\u003ctd\u003eSeries C I\/O Link\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Rate\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e750 KBaud\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Link Count\u003c\/td\u003e\n\u003ctd\u003e2 per C300 Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLink Designations\u003c\/td\u003e\n\u003ctd\u003eIOL1 and IOL2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Link Throughput\u003c\/td\u003e\n\u003ctd\u003e2,000 Link Units\/second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum I\/O Units\u003c\/td\u003e\n\u003ctd\u003e40 per I\/O Link\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecified CEE\u003c\/td\u003e\n\u003ctd\u003e50 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAddress Range\u003c\/td\u003e\n\u003ctd\u003e1–40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeader Cable Drops\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eLink Unit Definition:\u003c\/strong\u003e One Link Unit represents one parameter read or write per second. The documented throughput is 2,000 Link Units per second for Series C I\/O.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacity Consideration:\u003c\/strong\u003e Each C300 controller provides two I\/O Links. Each link supports up to 40 I\/O Units under the specified 50 ms CEE configuration. The three cable drops describe physical connection points, not three independent communication channels.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e03 | IOTA Interface \u0026amp; Mechanical Configuration\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe header cable connects the C300 Controller IOTA with compatible Series C IOTAs and IOMs. It also supports cabinet-side distribution through approved extension arrangements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSupported IOTA Sizes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e6-inch IOTA – 152 mm\u003c\/li\u003e\n\u003cli\u003e9-inch IOTA – 229 mm\u003c\/li\u003e\n\u003cli\u003e12-inch IOTA – 305 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInterface Configuration:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe C300 IOTA provides IOL1A\/B and IOL2A\/B connection positions.\u003c\/li\u003e\n\u003cli\u003eThe header cable interfaces with the designated IOTA connectors.\u003c\/li\u003e\n\u003cli\u003eDrop connections distribute the link to compatible Series C hardware.\u003c\/li\u003e\n\u003cli\u003eAdditional cables extend the approved cabinet wiring arrangement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe cable assembly has no built-in communication ports or active signal-processing components.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e04 | Installation \u0026amp; Cabinet Integration\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eCorrect routing and identification are essential for reliable Series C communication.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm the Part Number:\u003c\/strong\u003e Verify 51202329-600 against the cabinet wiring documentation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIdentify Cable A:\u003c\/strong\u003e Check the yellow identification label before installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify the Link:\u003c\/strong\u003e Confirm the IOL1A or IOL2A assignment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlan Cable Routing:\u003c\/strong\u003e Follow the approved horizontal cabinet-top routing arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck IOTA Positions:\u003c\/strong\u003e Confirm the installed 6-inch, 9-inch, or 12-inch IOTA configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnect the Drops:\u003c\/strong\u003e Match each of the three drops with the designated hardware connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck Cable Extensions:\u003c\/strong\u003e Verify the connection sequence when additional header or extension cables are present.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify Redundancy:\u003c\/strong\u003e Install the corresponding Cable B path when required.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eEngineering Note:\u003c\/strong\u003e The exact connector form factor and cable end-to-end length are not published in the reviewed Honeywell documentation. Follow the original cabinet drawings and approved installation instructions.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e05 | Redundancy \u0026amp; Configuration Control\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eHoneywell uses Cable A and Cable B as separate paths in redundant Series C I\/O Link installations.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRedundancy Path\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIdentification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable A\u003c\/td\u003e\n\u003ctd\u003eYellow Label\u003c\/td\u003e\n\u003ctd\u003ePrimary A-side cable path\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable B\u003c\/td\u003e\n\u003ctd\u003eGreen Label\u003c\/td\u003e\n\u003ctd\u003eCorresponding B-side cable path\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration Rules:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCable A and Cable B are required as a pair for the specified redundant architecture.\u003c\/li\u003e\n\u003cli\u003eEach cable has a separate identification label.\u003c\/li\u003e\n\u003cli\u003eThe cables may be supplied individually or as a pair.\u003c\/li\u003e\n\u003cli\u003eVerify the IOL1\/IOL2 assignment before connecting either path.\u003c\/li\u003e\n\u003cli\u003eDo not substitute Cable A for Cable B in a redundant installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCorrect cable pairing supports the intended communication architecture. Complete redundancy also depends on the controller and system configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e06 | Commissioning, Diagnostics \u0026amp; Maintenance\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eUse the following checks during initial commissioning and scheduled maintenance.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLabel Inspection:\u003c\/strong\u003e Confirm the yellow Cable A identification label.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLink Assignment:\u003c\/strong\u003e Verify IOL1 or IOL2 against the engineering drawings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrop Verification:\u003c\/strong\u003e Check all three connection points.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardware Recognition:\u003c\/strong\u003e Confirm the connected IOTAs and IOMs in the control system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Status:\u003c\/strong\u003e Review controller diagnostics for I\/O Link faults.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Check:\u003c\/strong\u003e Verify the corresponding B-side connection where applicable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Inspection:\u003c\/strong\u003e Check routing, connector seating, and visible cable damage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe passive assembly requires no separate software configuration. Commissioning focuses on correct wiring, hardware recognition, and system-level communication verification.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e07 | Compatibility \u0026amp; Engineering Applications\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e51202329-600\u003c\/strong\u003e is designed for the Honeywell Experion PKS Series C I\/O Link architecture.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible System Elements:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHoneywell Experion PKS Series C platform\u003c\/li\u003e\n\u003cli\u003eC300 Controller IOTA\u003c\/li\u003e\n\u003cli\u003eSeries C IOTAs and IOMs\u003c\/li\u003e\n\u003cli\u003eIOL1A and IOL2A cable connections\u003c\/li\u003e\n\u003cli\u003eCompatible 6-inch, 9-inch, and 12-inch IOTA configurations\u003c\/li\u003e\n\u003cli\u003eApproved Series C header and extension cable arrangements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTypical Engineering Applications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed I\/O cabinet interconnection\u003c\/li\u003e\n\u003cli\u003eProcess automation control cabinets\u003c\/li\u003e\n\u003cli\u003eMulti-CCA communication distribution\u003c\/li\u003e\n\u003cli\u003eSeries C I\/O expansion projects\u003c\/li\u003e\n\u003cli\u003eRedundant controller communication installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlways verify the exact cabinet topology and controller configuration. Do not assume compatibility with PM I\/O Link cable assemblies or unrelated communication interfaces.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e08 | Compliance \u0026amp; Technical Documentation\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell Series C platform references the following system-level standards:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61326-1:2013:\u003c\/strong\u003e Electromagnetic compatibility requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61010-1:\u003c\/strong\u003e Electrical equipment safety requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese standards apply to the documented Series C platform and its certified cabinet assembly. They do not establish separate UL, CE, or CSA certification for this passive cable assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Documentation References:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHoneywell Experion Control Hardware Planning Guide R301.1.\u003c\/li\u003e\n\u003cli\u003eHoneywell C300 Controller Capacity EP03-300-511.\u003c\/li\u003e\n\u003cli\u003eHoneywell Experion Series-C I\/O Specification EP03-490-520.\u003c\/li\u003e\n\u003cli\u003eHoneywell European Compliance Documentation EP03-520-515.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003e09 | Product Data \u0026amp; Supply Information\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrdering Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e51202329-600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExperion PKS Series C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/O Link Header Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Variant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCable A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLabel Color\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrop Quantity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 KBaud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndividual cable or A\/B pair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data Not Published by Honeywell:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePhysical connector type and form factor\u003c\/li\u003e\n\u003cli\u003eConductor gauge and cable core construction\u003c\/li\u003e\n\u003cli\u003eJacket material and flame rating\u003c\/li\u003e\n\u003cli\u003eIndividual cable weight\u003c\/li\u003e\n\u003cli\u003eIndividual cable operating temperature range\u003c\/li\u003e\n\u003cli\u003eIndividual cable IP rating\u003c\/li\u003e\n\u003cli\u003eFixed header cable length\u003c\/li\u003e\n\u003cli\u003ePer-cable UL, CE, or CSA certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese values require manufacturer confirmation. They should not be inferred from unrelated distributor descriptions.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e10 | Packaging \u0026amp; Ordering Checklist\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eStandard Product Identification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHoneywell 51202329-600 Series C I\/O Link Header Cable\u003c\/li\u003e\n\u003cli\u003eCable A configuration\u003c\/li\u003e\n\u003cli\u003eYellow identification label\u003c\/li\u003e\n\u003cli\u003eThree-drop connection arrangement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBefore Ordering:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm the required IOL1A or IOL2A assignment.\u003c\/li\u003e\n\u003cli\u003eConfirm whether Cable B is also required.\u003c\/li\u003e\n\u003cli\u003eCheck the number of cabinet drops.\u003c\/li\u003e\n\u003cli\u003eVerify the IOTA dimensions and cabinet layout.\u003c\/li\u003e\n\u003cli\u003eConfirm whether additional extension cables are needed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSupply Note:\u003c\/strong\u003e The listed identification does not establish the inclusion of Cable B or additional extension cables. Confirm the actual order scope and packing list with the supplier.\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":68028671688886,"sku":"51202329-600","price":130.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/51202329-600.jpg?v=1794297862","url":"https:\/\/www.plcsparehub.com\/products\/51202329-600-honeywell-experion-pks-header-cable","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}