{"product_id":"51195479-500-honeywell-pm-i-o-link-cable-set-experion-pks-c300-6-drop","title":"51195479-500 Honeywell PM I\/O Link Cable Set | Experion PKS C300 6-Drop","description":"\u003ch2\u003e51195479-500 Honeywell Experion PKS PM I\/O Link Cable Set\u003c\/h2\u003e\n\u003cp\u003eThe Honeywell 51195479-500 is a six-drop PM I\/O Link Cable Set designed for communication between a C300 Controller IOTA and PM files containing Process Manager Input\/Output Processors (PM IOPs). It operates on the Experion PKS PM I\/O Link at 375 KBaud, providing the physical communication path between the controller interface and the connected PM I\/O hardware.\u003c\/p\u003e\n\u003cp\u003eUnlike a conventional point-to-point cable, this assembly supports a multi-drop connection arrangement. Its six-drop configuration allows the PM I\/O Link to extend across the designated PM file connections within the control cabinet. For redundant PM I\/O Link installations, the A and B cable paths must be configured as a matching pair.\u003c\/p\u003e\n\u003ch3\u003e01 | Connection Architecture \u0026amp; Hardware Configuration\u003c\/h3\u003e\n\u003cp\u003eThe 51195479-500 functions as a passive, pre-terminated cable assembly. It does not contain an active communication interface or independent processing electronics. The C300 Controller IOTA requires the appropriate 51202341-112 adapter pair at the controller end.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e51195479-500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eExperion PKS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePM I\/O Link Cable Set\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eC300 Controller to PM File Connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Configuration\u003c\/td\u003e\n\u003ctd\u003e6-Drop Multi-Drop Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Family\u003c\/td\u003e\n\u003ctd\u003ePM I\/O Link\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLink Speed\u003c\/td\u003e\n\u003ctd\u003e375 KBaud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Interface\u003c\/td\u003e\n\u003ctd\u003ePassive, Pre-Terminated Cable Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController-End Adapter\u003c\/td\u003e\n\u003ctd\u003e51202341-112 Adapter Pair Required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Configuration\u003c\/td\u003e\n\u003ctd\u003eA+B Cable Pair for Redundant PM I\/O Link\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnected Equipment\u003c\/td\u003e\n\u003ctd\u003eC300 Controller IOTA and PM IOP Files\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e02 | Communication Performance \u0026amp; System Capacity\u003c\/h3\u003e\n\u003cp\u003eThe PM I\/O Link provides the communication path for PM I\/O data exchange with the C300 Controller. Its operating parameters are defined at the Experion PKS system level rather than by the passive cable assembly alone.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication Parameter\u003c\/th\u003e\n\u003cth\u003eSystem Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePM I\/O Link Rate\u003c\/td\u003e\n\u003ctd\u003e375 KBaud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailable Links per C300\u003c\/td\u003e\n\u003ctd\u003e2 (IOL1 and IOL2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLink Throughput\u003c\/td\u003e\n\u003ctd\u003e1,000 Link Units per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLink Unit Definition\u003c\/td\u003e\n\u003ctd\u003e1 parameter read\/write operation per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum I\/O Units per Link\u003c\/td\u003e\n\u003ctd\u003e40 at 50 ms CEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLink Redundancy\u003c\/td\u003e\n\u003ctd\u003eA\/B communication paths\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eEngineering note:\u003c\/strong\u003e The 1,000 LU\/s throughput and 40-unit capacity are PM I\/O Link system performance figures. They should not be interpreted as independent performance ratings of the cable assembly. Actual configuration must follow the applicable C300 and PM I\/O system design requirements.\u003c\/p\u003e\n\u003ch3\u003e03 | IOTA Identification \u0026amp; Cable Routing\u003c\/h3\u003e\n\u003cp\u003eCorrect I\/O Link identification is important when connecting multiple PM files or commissioning redundant communication paths.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eLink Identification\u003c\/th\u003e\n\u003cth\u003eColor Identification\u003c\/th\u003e\n\u003cth\u003eApplication\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIOL1A \/ IOL1B\u003c\/td\u003e\n\u003ctd\u003eGray\u003c\/td\u003e\n\u003ctd\u003eC300 I\/O Link 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIOL2A \/ IOL2B\u003c\/td\u003e\n\u003ctd\u003eViolet\u003c\/td\u003e\n\u003ctd\u003eC300 I\/O Link 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eDuring installation, verify the IOTA link designation before connecting the cable assembly. Keep the A and B paths correctly identified throughout cabinet wiring, particularly where redundant PM I\/O communication is implemented.\u003c\/p\u003e\n\u003ch3\u003e04 | Installation \u0026amp; Commissioning Considerations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the controller interface:\u003c\/strong\u003e Confirm that the C300 Controller IOTA has the required 51202341-112 adapter pair installed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify link assignment:\u003c\/strong\u003e Match the cable routing to IOL1 or IOL2 according to the approved cabinet wiring drawings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm redundancy:\u003c\/strong\u003e For redundant configurations, verify that both A and B paths are installed and connected to their designated interfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect all six drops:\u003c\/strong\u003e Check each connection point for correct termination, secure seating, and consistent identification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValidate communication:\u003c\/strong\u003e After installation, verify PM I\/O communication status through the Experion PKS engineering and diagnostic tools.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck system configuration:\u003c\/strong\u003e Confirm that PM IOP allocation and link loading remain within the applicable C300 system limits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e05 | Compatibility \u0026amp; Engineering Documentation\u003c\/h3\u003e\n\u003cp\u003eThe 51195479-500 belongs to the Honeywell Experion PKS PM I\/O Link accessory family. Its intended application is the connection of a C300 Controller IOTA to PM files containing PM IOPs.\u003c\/p\u003e\n\u003cp\u003eRelevant Honeywell engineering references include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eR301.1 – Experion Control Hardware Planning Guide:\u003c\/strong\u003e PM I\/O Link cable part information and hardware identification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEP03-300-511, Section 2.3.1:\u003c\/strong\u003e PM I\/O Link communication speed and C300 link configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEP03-300-511, Section 4.0:\u003c\/strong\u003e PM I\/O capacity information.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEP03-490-520, Version 1.5:\u003c\/strong\u003e Series C platform documentation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEP03-520-515:\u003c\/strong\u003e Series C platform EMC and electrical safety compliance information.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe Series C platform references EN 61326-1:2013 for EMC and IEC\/EN 61010-1 for electrical safety. These are platform-level compliance references, not independent certifications for the 51195479-500 cable set.\u003c\/p\u003e\n\u003ch3\u003e06 | Procurement \u0026amp; Industrial Support\u003c\/h3\u003e\n\u003cp\u003eWhen ordering the Honeywell 51195479-500, provide the complete part number and confirm whether the application requires a single cable assembly or a redundant A\/B pair.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProduct: Honeywell 51195479-500\u003c\/li\u003e\n\u003cli\u003eCondition: New and Original\u003c\/li\u003e\n\u003cli\u003eWarranty: 12 Months\u003c\/li\u003e\n\u003cli\u003eShipping: FedEx, UPS, or DHL\u003c\/li\u003e\n\u003cli\u003eDispatch: Typically within 5 working days, subject to stock confirmation\u003c\/li\u003e\n\u003cli\u003eReturns: 30-Day Return Support, subject to applicable terms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eContact our team with your C300 Controller IOTA configuration and PM file requirements. We can help verify the correct cable arrangement before purchase.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can the 51195479-500 be used to connect PM IOPs directly to a standalone PLC?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. This assembly belongs to the Honeywell Experion PKS PM I\/O architecture. It is intended for the specified C300-to-PM I\/O connection and is not a general-purpose PLC communication cable. A different controller interface would require its own supported hardware architecture.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What should engineers check if PM I\/O communication becomes intermittent after cabinet maintenance?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStart by inspecting the cable terminations, adapter seating, and IOL1\/IOL2 assignments. For redundant installations, compare the A and B communication paths separately. Also review controller diagnostics and PM I\/O communication status before replacing the cable assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Does the six-drop configuration mean that six PM IOPs can be connected?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNot necessarily. Six drops describe the cable assembly's connection arrangement, not a guaranteed number of individual IOPs. The actual supported I\/O configuration depends on PM file architecture, link loading, and the applicable Experion PKS hardware limits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Can I replace only one cable path in a redundant installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA single-path replacement may be possible when the fault is isolated to that path. However, engineers should verify the installed A\/B topology, part-number compatibility, and system redundancy status before returning the equipment to service. Avoid disconnecting both paths simultaneously during an operating-system maintenance window.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: How can purchasing teams avoid ordering the wrong PM I\/O Link cable variant?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCompare the complete part number against the existing cabinet bill of materials and Honeywell hardware planning documentation. Also verify the number of drops, controller-end adapter requirements, and redundancy arrangement. Do not select a replacement based solely on a distributor's claimed cable length or connector description.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":68028658614454,"sku":"51195479-500","price":116.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/51195479-500.jpg?v=1794297540","url":"https:\/\/www.plcsparehub.com\/products\/51195479-500-honeywell-pm-i-o-link-cable-set-experion-pks-c300-6-drop","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}