{"product_id":"5069-l340erm-allen-bradley-compactlogix-5380-motion-controller","title":"5069-L340ERM Allen Bradley CompactLogix 5380 Motion Controller","description":"\u003ch3\u003e\u003cstrong\u003eController Architecture \u0026amp; Motion Control Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eMachine builders deploy the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e5069-L340ERM\u003c\/strong\u003e\u003c\/span\u003e \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eAllen Bradley\u003c\/strong\u003e\u003c\/span\u003e \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eCompactLogix 5380\u003c\/strong\u003e\u003c\/span\u003e standard controller to execute high-speed multi-axis motion and deterministic process control within a compact DIN-rail footprint. Equipped with 4 MB of user application memory and a bundled 2 GB \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e1784-SD2\u003c\/strong\u003e\u003c\/span\u003e non-volatile memory card, this Programmable Automation Controller (PAC) coordinates up to 20 integrated CIP motion axes alongside 31 local 5069 I\/O modules. Its dual Gigabit EtherNet\/IP ports support Device Level Ring (DLR) redundancy and Dual-IP network segmentation across up to 90 Ethernet nodes.\u003c\/p\u003e\n\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" width=\"100%\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth align=\"left\"\u003eSystem Domain\u003c\/th\u003e\n      \u003cth align=\"left\"\u003eEngineering Parameter\u003c\/th\u003e\n      \u003cth align=\"left\"\u003eRated Specification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIdentification\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eManufacturer, Part Number \u0026amp; Line\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eAllen Bradley 5069-L340ERM\u003c\/strong\u003e\u003c\/span\u003e (\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eCompactLogix 5380\u003c\/strong\u003e\u003c\/span\u003e \/ 5069)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMemory \u0026amp; Software\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUser RAM, SD Storage \u0026amp; IDE\u003c\/td\u003e\n      \u003ctd\u003e4 MB built-in RAM; 2 GB via 1784-SD2 card; Studio 5000 v31 or later\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMotion Control\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCIP Axes \u0026amp; Total Motion Axes\u003c\/td\u003e\n      \u003ctd\u003eUp to 20 CIP drive axes; 256 total axes (Virtual, Consumed, Converters)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eI\/O \u0026amp; Special Functions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLocal Modules \u0026amp; High-Speed Capture\u003c\/td\u003e\n      \u003ctd\u003e31 local 5069 I\/O modules; hardware pulse latching \u0026amp; pattern matching\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePorts, Speeds \u0026amp; Topologies\u003c\/td\u003e\n      \u003ctd\u003e2× 10\/100\/1000 Mbps EtherNet\/IP (DLR, Star, Linear, Dual-IP); 1× USB 2.0 (12 Mbps)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNetwork Capacity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNodes \u0026amp; Socket Connections\u003c\/td\u003e\n      \u003ctd\u003e90 total Ethernet nodes (55 EtherNet\/IP nodes); 32 socket connections\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMOD Power Bus\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eVoltage, Draw \u0026amp; Bus Passthrough\u003c\/td\u003e\n      \u003ctd\u003e18–32V DC range; 450 mA max draw (850 mA inrush\/125 ms); 9.55 A bus rating\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSA Field Power\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAC\/DC Ratings \u0026amp; Passthrough\u003c\/td\u003e\n      \u003ctd\u003e0–32V DC (10 mA max, 9.95 A bus) \/ 0–240V AC 47–63 Hz (25 mA max, 9.975 A bus; 125V AC max ATEX\/IECEx)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePhysical\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eShipping Weight \u0026amp; UPC\u003c\/td\u003e\n      \u003ctd\u003e2.00 lbs (0.91 kg); UPC 887172922190\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cstrong\u003eKey Engineering Advantages \u0026amp; Programming Standards\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual-IP Network Isolation:\u003c\/strong\u003e Configure the dual Gigabit Ethernet ports independently to physically isolate high-speed CIP Sync servo drive traffic from enterprise SCADA, MES, and HMI communications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDeterministic Servo Coordination:\u003c\/strong\u003e Supports 20 closed-loop CIP Drive axes plus virtual and regenerative AC\/DC converter axes using IEC 61131-3 languages (Ladder Diagram, Structured Text, Function Block, Sequential Function Chart).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSegregated Power Architecture:\u003c\/strong\u003e Separates Module (MOD) logic power from Sensor\/Actuator (SA) field power, enabling safe removal of field actuator voltage without dropping controller backplane communication.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandard Non-Safety Architecture:\u003c\/strong\u003e Engineered specifically for high-throughput standard automation and motion tasks (for integrated GuardLogix SIL 3\/PLe safety functions, specify a 5069-L340ERMS2\/ERMS3 model).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eField Engineering FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How do I configure the dual EtherNet\/IP ports on the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e5069-L340ERM\u003c\/strong\u003e\u003c\/span\u003e for Dual-IP mode versus DLR mode?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: Open the controller properties in Studio 5000 Logix Designer (version 31 or later), navigate to the Network Configuration tab, and toggle between Linear\/DLR mode (single IP address across both ports) and Dual-IP mode (two separate subnet IP addresses).\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: What happens if I exceed the 9.55 A MOD power or 9.95 A SA field power passthrough limits across 31 local I\/O modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: Exceeding backplane current capacity causes voltage sag and intermittent module faults. Insert a 5069-FPD Field Potential Distributor module mid-bank to inject a fresh 24V DC power bus segment for downstream high-density I\/O slices.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: Can I open a project created in Studio 5000 v30 or earlier on this controller?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: No, the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e5069-L340ERM\u003c\/strong\u003e\u003c\/span\u003e hardware firmware requires Studio 5000 Logix Designer version 31 or higher. You must convert legacy L5K or ACD project files up to v31+ prior to downloading.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ4: Why is the bundled 1784-SD2 2 GB SD card critical during unmanned night-shift maintenance?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA4: By setting the controller's non-volatile load option to \"On Power Up\" or \"On Corrupt Memory,\" the processor automatically reloads the user program and firmware from the 1784-SD2 card after severe power transients without requiring an engineer with a laptop.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ5: How do hardware pulse latching and pattern matching improve high-speed packaging machine accuracy?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA5: Built-in hardware pulse latching captures registration sensor edges directly at the bus level independent of main PLC scan times, eliminating variable scan jitter during high-speed rotary knife cutting and label application.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":68083639976118,"sku":"5069-L340ERM","price":163.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/5069-L340ERM-1.jpg?v=1794900122","url":"https:\/\/www.plcsparehub.com\/products\/5069-l340erm-allen-bradley-compactlogix-5380-motion-controller","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}