{"product_id":"499aoz-54-03cc-rosemount-analytical-ozone-sensor","title":"499AOZ-54-03CC Rosemount Analytical Ozone Sensor","description":"\u003ch3\u003e\u003cstrong\u003e499AOZ-54-03CC Rosemount Analytical Dissolved Ozone Sensor\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eRosemount Analytical \u003cspan style=\"color:#c0392b;\"\u003e499AOZ-54-03CC\u003c\/span\u003e\u003c\/strong\u003e provides stable dissolved ozone measurement for industrial liquid analysis systems.\u003c\/p\u003e\n\n\u003cp\u003eThe sensor supports continuous ozone monitoring in demanding water treatment applications.\u003c\/p\u003e\n\n\u003cp\u003eIts membrane-based sensing structure improves measurement consistency during process fluctuations.\u003c\/p\u003e\n\n\u003cp\u003eThe ozone-resistant polysulfone body enhances durability in oxidizing environments.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#c0392b;\"\u003e499AOZ-54-03CC\u003c\/span\u003e\u003c\/strong\u003e integrates efficiently with Rosemount analytical transmitters.\u003c\/p\u003e\n\n\u003cp\u003eThe protected cable design improves signal stability in electrically noisy industrial facilities.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eDesigned for Continuous Ozone Process Control\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003ePressure equalization stabilizes membrane tension during process pressure changes.\u003c\/li\u003e\n\u003cli\u003eAutomatic permeability compensation improves measurement repeatability.\u003c\/li\u003e\n\u003cli\u003eTool-free membrane replacement reduces maintenance complexity.\u003c\/li\u003e\n\u003cli\u003eEMI\/RFI protected cable improves signal integrity.\u003c\/li\u003e\n\u003cli\u003eVariopol connector option simplifies sensor replacement procedures.\u003c\/li\u003e\n\u003cli\u003eCompact sensor structure supports flexible installation configurations.\u003c\/li\u003e\n\u003cli\u003eCalibration certificate option supports quality assurance documentation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTechnical Performance Summary\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Rosemount Analytical Inc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color:#c0392b;\"\u003e499AOZ-54-03CC\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Rosemount 499AOZ Series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Dissolved Ozone Sensor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Technology:\u003c\/strong\u003e Membrane-covered amperometric measurement\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBody Material:\u003c\/strong\u003e Ozone-resistant polysulfone\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient Temperature Range:\u003c\/strong\u003e 32 to 122 °F (0 to 50 °C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e Dependent on calibration chemical reference accuracy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Configuration:\u003c\/strong\u003e Integral 33-ft. EMI\/RFI protected cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Option:\u003c\/strong\u003e Variopol quick-disconnect compatible\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration Certificate:\u003c\/strong\u003e CC Certificate of Calibration available\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e Approx. 0.5 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e Approx. 1.5 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Stability:\u003c\/strong\u003e Automatic membrane permeability compensation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Compensation:\u003c\/strong\u003e Integrated pressure equalization system\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Type:\u003c\/strong\u003e Continuous process liquid monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eCompatible Analytical Platforms\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eRosemount 1056 analyzers\u003c\/li\u003e\n\u003cli\u003eRosemount 1066-DO transmitters\u003c\/li\u003e\n\u003cli\u003eRosemount 56 multiparameter transmitters\u003c\/li\u003e\n\u003cli\u003eRosemount 5081-A analytical systems\u003c\/li\u003e\n\u003cli\u003eIndustrial disinfection monitoring systems\u003c\/li\u003e\n\u003cli\u003eWater treatment process skids\u003c\/li\u003e\n\u003cli\u003eOzone injection control systems\u003c\/li\u003e\n\u003cli\u003eMunicipal treatment automation platforms\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#c0392b;\"\u003eRosemount 499AOZ Series\u003c\/span\u003e\u003c\/strong\u003e sensors perform effectively in continuous ozone disinfection applications.\u003c\/p\u003e\n\n\u003cp\u003eThe membrane compensation structure improves process stability during pressure fluctuations.\u003c\/p\u003e\n\n\u003cp\u003eEngineers often select this sensor for installations requiring dependable long-duration operation.\u003c\/p\u003e\n\n\u003cp\u003eThe EMI\/RFI protected cable improves performance near large motor-driven equipment.\u003c\/p\u003e\n\n\u003cp\u003eThe quick-service membrane design reduces maintenance interruption during calibration cycles.\u003c\/p\u003e\n\n\u003cp\u003eThis sensor configuration supports process optimization in ozone-controlled water treatment systems.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eRecommended Industrial Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eMunicipal drinking water treatment\u003c\/li\u003e\n\u003cli\u003eIndustrial wastewater oxidation systems\u003c\/li\u003e\n\u003cli\u003eFood and beverage sanitation loops\u003c\/li\u003e\n\u003cli\u003ePharmaceutical purified water systems\u003c\/li\u003e\n\u003cli\u003eCooling water treatment systems\u003c\/li\u003e\n\u003cli\u003eSemiconductor ultrapure water facilities\u003c\/li\u003e\n\u003cli\u003eChemical disinfection process monitoring\u003c\/li\u003e\n\u003cli\u003eIndustrial ozone dosing control systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eDiagnostic and Maintenance Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eMembrane condition changes remain easy to identify during inspection.\u003c\/li\u003e\n\u003cli\u003ePressure equalization reduces unstable reading behavior.\u003c\/li\u003e\n\u003cli\u003eProtected signal cable minimizes electrical interference issues.\u003c\/li\u003e\n\u003cli\u003eQuick membrane replacement shortens maintenance duration.\u003c\/li\u003e\n\u003cli\u003eCalibration support improves process verification efficiency.\u003c\/li\u003e\n\u003cli\u003eStable sensor response assists troubleshooting procedures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eEngineering Installation Recommendations\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eInstall the sensor in locations with stable sample flow.\u003c\/li\u003e\n\u003cli\u003eAvoid trapped air bubbles near the membrane surface.\u003c\/li\u003e\n\u003cli\u003eProtect cable routing from excessive mechanical stress.\u003c\/li\u003e\n\u003cli\u003eVerify calibration after membrane replacement procedures.\u003c\/li\u003e\n\u003cli\u003eMaintain clean sample conditions for stable measurements.\u003c\/li\u003e\n\u003cli\u003eInspect membrane integrity during scheduled service intervals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eShipping and Warranty Support\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e12-month factory warranty included.\u003c\/li\u003e\n\u003cli\u003eFactory-sealed industrial packaging provided.\u003c\/li\u003e\n\u003cli\u003eFedEx international shipment available.\u003c\/li\u003e\n\u003cli\u003eUPS worldwide logistics supported.\u003c\/li\u003e\n\u003cli\u003eDHL expedited delivery available.\u003c\/li\u003e\n\u003cli\u003eFast dispatch for urgent process maintenance requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eProfessional FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhy is pressure equalization important in dissolved ozone measurement?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003ePressure equalization maintains stable membrane tension during fluctuating process conditions.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat process conditions most affect membrane lifespan?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eHigh contamination levels and unstable sample flow can shorten membrane service intervals.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhy do engineers prefer EMI\/RFI protected analytical cables?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eProtected cables improve signal reliability near motors, drives, and switching equipment.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eHow can technicians improve dissolved ozone measurement consistency?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eMaintain stable flow conditions and perform regular calibration verification procedures.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat should buyers evaluate before selecting an ozone monitoring sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eReview transmitter compatibility, installation environment, maintenance accessibility, and sample chemistry conditions.\u003c\/p\u003e","brand":"Rosemount","offers":[{"title":"Default Title","offer_id":45138191974582,"sku":"499AOZ-54-03CC","price":218.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/499AOZ-54-03CC.jpg?v=1779442960","url":"https:\/\/www.plcsparehub.com\/products\/499aoz-54-03cc-rosemount-analytical-ozone-sensor","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}