{"product_id":"3bse072270r1-abb-ac-800m-sm812k01-sil3-safety-cpu-module","title":"3BSE072270R1 ABB AC 800M SM812K01 SIL3 Safety CPU Module","description":"\u003ch3\u003e\u003cstrong\u003eABB 3BSE072270R1 SM812K01 – Safety Control Core\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #0066cc;\"\u003eABB 3BSE072270R1\u003c\/span\u003e\u003c\/strong\u003e is an SM812K01 Safety CPU module for ABB AC 800M safety control systems.\u003c\/p\u003e\n\u003cp\u003eIt provides high-integrity processing for safety-related control applications. The module supports redundant configurations and SIL 3 applications when correctly engineered and configured.\u003c\/p\u003e\n\u003cp\u003eThis product package includes the SM812 Safety Module, TP868 Baseplate, and TK852V10 synchronization link cable. It is specified for use with PM857, PM863, and PM867 controllers.\u003c\/p\u003e\n\u003cp\u003eFor system integration, check the controller configuration, firmware revision, and 800xA version before installation. The stated compatibility begins with ABB System 800xA 6.0.2.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e01 | Safety Architecture and Operating Role\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety processing:\u003c\/strong\u003e Executes application logic for high-integrity control functions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSIL capability:\u003c\/strong\u003e Designed for SIL 3 safety applications, subject to the applicable safety manual and system requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant operation:\u003c\/strong\u003e Supports redundant configurations with a maximum stated switchover time of 10 ms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController integration:\u003c\/strong\u003e Specified for use with PM857, PM863, and PM867.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem compatibility:\u003c\/strong\u003e Compatible with ABB System 800xA 6.0.2 and later, subject to configuration requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEngineering note:\u003c\/strong\u003e SIL 3 capability does not automatically establish the safety integrity of the complete application. The system design, configuration, validation, and maintenance must follow ABB safety documentation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e02 | Hardware and Performance Profile\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle number\u003c\/td\u003e\n\u003ctd\u003e3BSE072270R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct model\u003c\/td\u003e\n\u003ctd\u003eSM812K01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003eSafety CPU Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem family\u003c\/td\u003e\n\u003ctd\u003eABB AC 800M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor type\u003c\/td\u003e\n\u003ctd\u003eMPC866\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClock frequency\u003c\/td\u003e\n\u003ctd\u003e133 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003e64 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirmware storage\u003c\/td\u003e\n\u003ctd\u003e4 MB Flash PROM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication flash storage\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh integrity\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundant configuration switchover\u003c\/td\u003e\n\u003ctd\u003eMaximum 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance data:\u003c\/strong\u003e The supplied specifications do not state a confirmed Boolean operation rate or application-available RAM value. These figures should be checked against the applicable ABB technical documentation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e03 | Power Supply and Electrical Data\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermitted voltage range\u003c\/td\u003e\n\u003ctd\u003e19.2–30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical current consumption\u003c\/td\u003e\n\u003ctd\u003e160 mA at 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum current consumption\u003c\/td\u003e\n\u003ctd\u003e250 mA at 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower dissipation\u003c\/td\u003e\n\u003ctd\u003e3.8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated isolation voltage\u003c\/td\u003e\n\u003ctd\u003e50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric test voltage\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCheck the 24 V DC supply under normal and peak loading conditions. Include the module and associated system loads in the power budget.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e04 | Environmental Limits and Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironmental parameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e0 to +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature change\u003c\/td\u003e\n\u003ctd\u003e3 °C\/min, IEC\/EN 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity\u003c\/td\u003e\n\u003ctd\u003e5–95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution degree\u003c\/td\u003e\n\u003ctd\u003eDegree 2, IEC\/EN 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrosion protection\u003c\/td\u003e\n\u003ctd\u003eG3 compliant with ISA 71.04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class\u003c\/td\u003e\n\u003ctd\u003eIP20, EN 60529 \/ IEC 529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum stated altitude\u003c\/td\u003e\n\u003ctd\u003e2000 m, IEC\/EN 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcoustic noise\u003c\/td\u003e\n\u003ctd\u003eLess than 55 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental classification\u003c\/td\u003e\n\u003ctd\u003eIndustrial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eVibration limits:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e10–50 Hz: 0.0375 mm amplitude.\u003c\/li\u003e\n\u003cli\u003e50–150 Hz: 0.5 g acceleration.\u003c\/li\u003e\n\u003cli\u003e5–500 Hz: 0.2 g acceleration, as separately stated in the supplied data.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe supplied vibration ranges overlap and should be checked against the official ABB datasheet before using them as installation acceptance limits.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e05 | Dimensions and Mechanical Data\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e59 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e186 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e127.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.63 kg, stated product weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight including base\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAllow sufficient cabinet clearance for the module, baseplate, wiring, and maintenance access. Confirm the mechanical arrangement against the ABB installation drawings.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e06 | Package Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe stated 3BSE072270R1 package includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSM812:\u003c\/strong\u003e Safety Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTP868:\u003c\/strong\u003e Baseplate\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTK852V10:\u003c\/strong\u003e Synchronization link cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCheck the supplied components against the purchase order before installation. Additional accessories and documentation depend on the order configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e07 | Installation and Commissioning Considerations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify the system architecture.\u003c\/strong\u003e Confirm the intended PM controller and safety CPU arrangement before mounting the module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck software compatibility.\u003c\/strong\u003e Confirm the installed System 800xA version is 6.0.2 or later. Verify the applicable controller and firmware revisions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect the package.\u003c\/strong\u003e Check the SM812 module, TP868 baseplate, and TK852V10 synchronization cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify the power supply.\u003c\/strong\u003e Confirm the 24 V DC supply remains within the specified 19.2–30 V range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfigure the safety application.\u003c\/strong\u003e Follow the ABB Safety Manual and applicable project configuration rules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValidate redundancy.\u003c\/strong\u003e Check synchronization, controller status, and switchover behavior using the approved commissioning procedure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplete safety validation.\u003c\/strong\u003e Perform the required functional tests and document the results before placing the application into service.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Do not treat a successful CPU startup as proof of safety function integrity. Complete the required application validation and safety acceptance process.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e08 | Certifications and Compliance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eStated compliance or approval\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional safety\u003c\/td\u003e\n\u003ctd\u003eSIL 3 certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTÜV approval\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC emission\u003c\/td\u003e\n\u003ctd\u003eEN 61000-6-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC immunity\u003c\/td\u003e\n\u003ctd\u003eEN 61000-6-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical safety\u003c\/td\u003e\n\u003ctd\u003eEN 50178, IEC 61131-2, UL 61010-1, UL 61010-2-201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous location\u003c\/td\u003e\n\u003ctd\u003ecULus Class 1, Zone 2; AEx nA IIC T4; Ex nA IIC T4 Gc X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarine approvals\u003c\/td\u003e\n\u003ctd\u003eABS, BV, DNV, LR, CCS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS\u003c\/td\u003e\n\u003ctd\u003eEU RoHS, UAE RoHS, CN RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEE\u003c\/td\u003e\n\u003ctd\u003eDirective 2012\/19\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE marking\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eConfirm the applicable certificate scope and product revision for the intended installation. Hazardous-area use must follow the certificate conditions and local regulations.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":68112864673974,"sku":"SM812K01","price":412.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/SM812K01-3.jpg?v=1795162489","url":"https:\/\/www.plcsparehub.com\/products\/3bse072270r1-abb-ac-800m-sm812k01-sil3-safety-cpu-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}