{"product_id":"3aua0000089107-fena-11-abb-fieldbus-kit-ethernet-interface","title":"3AUA0000089107 FENA-11 ABB FieldBus Kit Ethernet Interface","description":"\u003ch3\u003e\u003cstrong\u003e\u003cmark\u003e3AUA0000089107\u003c\/mark\u003e ABB FENA-11 ACS880 Ethernet Adapter\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Brief | Three Industrial Protocols, One Drive Interface\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cmark\u003eABB FENA-11\u003c\/mark\u003e\u003c\/strong\u003e is a single-port Ethernet adapter for compatible ABB drives, including supported ACS880 configurations.\u003c\/p\u003e\n\u003cp\u003eIt connects drive control units to industrial Ethernet networks. The module supports \u003cstrong\u003ePROFINET IO, EtherNet\/IP, and Modbus TCP\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eEngineers select the communication protocol through a drive parameter. This approach supports integration with different PLC and automation platforms without changing the adapter's physical Ethernet interface.\u003c\/p\u003e\n\u003cp\u003eThe FENA-11 exchanges drive commands, references, status information, and process data. Its protocol-specific profiles support standardized drive communication or transparent data mapping.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ABB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct model:\u003c\/strong\u003e FENA-11\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct ID:\u003c\/strong\u003e 3AUA0000089107\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e ABB FieldBus Kit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCatalog description:\u003c\/strong\u003e Ethernet Adapter for Modbus TCP, EtherNet\/IP, and PROFINET IO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 6438177287445\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntended platform:\u003c\/strong\u003e Compatible ABB drives, including supported ACS880 models\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondition:\u003c\/strong\u003e New and original factory packing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCommunication Architecture | Select the Protocol for Your Control System\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe adapter provides one RJ-45 Ethernet port. The selected protocol determines how the PLC or controller exchanges data with the drive.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eProtocol\u003c\/th\u003e\n\u003cth\u003eAdapter role\u003c\/th\u003e\n\u003cth\u003eSupported communication features\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROFINET IO\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePROFINET IO device\u003c\/td\u003e\n\u003ctd\u003eDP-V1 communication, PROFIdrive and ABB drive profiles, plus 16-bit and 32-bit transparent modes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEtherNet\/IP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEtherNet\/IP server\u003c\/td\u003e\n\u003ctd\u003eODVA AC\/DC Drive, ABB drive, and transparent profiles; explicit and implicit messaging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModbus TCP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus TCP server\u003c\/td\u003e\n\u003ctd\u003eABB drive and transparent profiles; single-register and multiple-register read\/write functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eEngineering distinction:\u003c\/strong\u003e The FENA-11 supports these protocols, but it does not operate all three simultaneously. Configure the required protocol through the drive's applicable parameter.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDrive Data Exchange | Control, Reference, and Feedback\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe controller can use the adapter to exchange information with the drive.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommand channel:\u003c\/strong\u003e Transfer supported drive control commands from the PLC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReference channel:\u003c\/strong\u003e Send configured speed, torque, or other supported reference values.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFeedback channel:\u003c\/strong\u003e Read drive status and selected actual values.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eParameter access:\u003c\/strong\u003e Use supported protocol services to access drive parameters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication data:\u003c\/strong\u003e Configure profile-based or transparent data exchange for the control application.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eAvailable signals and control functions depend on the drive firmware, selected profile, and parameter configuration. Confirm the required data mapping in the applicable ABB documentation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications | Hardware at a Glance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cmark\u003eFENA-11\u003c\/mark\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrdering number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3AUA0000089107\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule type\u003c\/td\u003e\n\u003ctd\u003eSingle-port industrial Ethernet adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive interface\u003c\/td\u003e\n\u003ctd\u003e20-pin connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet interface\u003c\/td\u003e\n\u003ctd\u003eRJ-45, connector X1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Ethernet standards\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3 and IEEE 802.3u\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical media\u003c\/td\u003e\n\u003ctd\u003e10BASE-TX or 100BASE-TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer rates\u003c\/td\u003e\n\u003ctd\u003e10 Mbps or 100 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDuplex mode\u003c\/td\u003e\n\u003ctd\u003eHalf-duplex or full-duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLink functions\u003c\/td\u003e\n\u003ctd\u003eAutonegotiation and Auto-MDIX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum segment length\u003c\/td\u003e\n\u003ctd\u003e100 m (328 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eBus or star\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e+3.3 V ±5%, supplied by the drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum current consumption\u003c\/td\u003e\n\u003ctd\u003e400 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct net width\u003c\/td\u003e\n\u003ctd\u003e115 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct net height\u003c\/td\u003e\n\u003ctd\u003e5 mm, as listed in the supplied product data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct net weight\u003c\/td\u003e\n\u003ctd\u003e0.18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC compliance\u003c\/td\u003e\n\u003ctd\u003eEN 61800-3:2004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCB construction\u003c\/td\u003e\n\u003ctd\u003eConformal-coated printed circuit board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eDimension note:\u003c\/strong\u003e The supplied data lists a net height of 5 mm. Verify the complete mechanical drawing before checking enclosure clearance or replacement fit.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eNetwork Installation | Cable, Connector, and Topology\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe FENA-11 uses standard industrial Ethernet cabling and an RJ-45 connection. Select cable construction according to the installation environment.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupported cable:\u003c\/strong\u003e CAT5 or CAT6 UTP, FTP, or STP.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector:\u003c\/strong\u003e RJ-45 Ethernet port X1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTermination:\u003c\/strong\u003e Internal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum cable segment:\u003c\/strong\u003e 100 m.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTopology:\u003c\/strong\u003e Bus or star, subject to the selected protocol and network equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDaisy-chain note:\u003c\/strong\u003e The supplied documentation identifies a 50-node daisy-chain limit for FENA-21. Do not apply this limit to FENA-11 without confirmation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eUse suitable Ethernet switches when the control architecture requires multiple network branches. Keep communication cabling away from high-noise power conductors where practical.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDrive Compatibility | Confirm the Option Slot Before Ordering\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFENA-11\u003c\/strong\u003e installs into an option slot on a compatible ABB drive control unit. The drive supplies the module's power and connects through its 20-pin interface.\u003c\/p\u003e\n\u003cp\u003eFor an ACS880 application, verify the exact drive variant, control unit, firmware, and approved fieldbus options. The ACS880 family name alone does not confirm compatibility with every hardware revision.\u003c\/p\u003e\n\u003cp\u003eAlso confirm the PLC's supported protocol and configuration method. A PROFINET project, EtherNet\/IP project, and Modbus TCP project require different controller-side setup.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Commissioning | Practical Sequence\u003c\/strong\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eIdentify the drive model and locate its approved Ethernet adapter option slot.\u003c\/li\u003e\n\u003cli\u003eIsolate drive power and follow the manufacturer's electrical safety procedure.\u003c\/li\u003e\n\u003cli\u003eInsert the adapter into the designated slot and secure it as instructed by the drive manual.\u003c\/li\u003e\n\u003cli\u003eConnect the Ethernet cable to the RJ-45 port.\u003c\/li\u003e\n\u003cli\u003eSet the required protocol using the applicable drive parameter.\u003c\/li\u003e\n\u003cli\u003eConfigure the PLC or controller using the correct protocol profile and device configuration.\u003c\/li\u003e\n\u003cli\u003eVerify network communication before enabling remote drive control.\u003c\/li\u003e\n\u003cli\u003eTest command, reference, feedback, and fault-handling functions under approved commissioning conditions.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eFollow the drive-specific installation instructions. Do not insert or remove the module while the drive remains energized unless ABB explicitly permits that procedure.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eLED Diagnostics | Interpreting Communication Conditions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe adapter has three bicolor LED indicators: \u003cstrong\u003eHOST, MODULE, and NETWORK\/NET\u003c\/strong\u003e. They provide visual information about the host connection, module condition, and network communication.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eIndicator\u003c\/th\u003e\n\u003cth\u003eDiagnostic focus\u003c\/th\u003e\n\u003cth\u003eRecommended check\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHOST\u003c\/td\u003e\n\u003ctd\u003eDrive-side interface\u003c\/td\u003e\n\u003ctd\u003eCheck option-slot seating and the drive's recognition of the adapter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMODULE\u003c\/td\u003e\n\u003ctd\u003eAdapter operating condition\u003c\/td\u003e\n\u003ctd\u003eConsult the relevant ABB manual for the observed color and flashing pattern.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNETWORK\/NET\u003c\/td\u003e\n\u003ctd\u003eEthernet link and network activity\u003c\/td\u003e\n\u003ctd\u003eCheck cable connection, switch port, protocol configuration, and controller communication.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe exact LED meanings depend on the documented indicator patterns. Use the ABB manual to interpret specific colors and flash sequences rather than assuming a universal code.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCommissioning example:\u003c\/strong\u003e A drive appears offline after a controller change. Check the NET indicator and physical link first. Then verify the selected protocol and controller configuration. Finally, inspect drive-side recognition and profile settings.\u003c\/p\u003e\n\u003cp\u003eThis sequence separates physical connectivity issues from configuration errors. The adapter does not independently diagnose motor, bearing, or mechanical faults.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Fit | Where FENA-11 Adds Value\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eACS880 motor drives:\u003c\/strong\u003e Connect compatible drive installations to industrial Ethernet controllers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConveyors and material handling:\u003c\/strong\u003e Exchange drive commands and speed feedback with PLC-controlled lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePumps and fans:\u003c\/strong\u003e Integrate supported drive references and operating feedback into process automation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial process systems:\u003c\/strong\u003e Use Modbus TCP, PROFINET IO, or EtherNet\/IP according to the control-system architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMachine-building projects:\u003c\/strong\u003e Standardize drive communication when the selected controller supports the required protocol.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrive modernization:\u003c\/strong\u003e Replace or add a communication interface after verifying the drive's approved option configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight | Engineering Selection Advice\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eChoose the communication protocol based on the controller architecture, not simply the available Ethernet port.\u003c\/p\u003e\n\u003cp\u003eFor example, a machine using a PROFINET-based PLC may require the PROFIdrive profile. A system using EtherNet\/IP may need the ODVA AC\/DC Drive profile. Transparent modes may suit applications with custom data mapping.\u003c\/p\u003e\n\u003cp\u003eBefore ordering, confirm three interfaces: the adapter's drive-side connector, the controller's protocol support, and the application's required process-data layout. This review reduces configuration changes during commissioning.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePackaging, Shipping, and Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage contents:\u003c\/strong\u003e One ABB FENA-11 Ethernet adapter. Confirm included accessories against the order and supplier packing list.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory packaging:\u003c\/strong\u003e The supplied product information specifies cardboard packaging and antistatic PE bubble wrapping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12 months, subject to the seller's applicable warranty terms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping carriers:\u003c\/strong\u003e FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch target:\u003c\/strong\u003e 24–48 hours after order confirmation and stock verification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrdering support:\u003c\/strong\u003e Provide the complete product ID and drive model for compatibility review.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions | Selection and Field Experience\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. Can the FENA-11 connect directly to a standard office Ethernet network?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt uses standard Ethernet physical media, but the control network requires suitable protocol support and configuration. Follow the plant's network-security and segmentation requirements before connecting it to an enterprise network.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. How do I choose between the ABB drive profile and transparent mode?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse a drive profile when the controller supports its defined drive data structure. Consider transparent mode when the application requires custom word-based mapping. Confirm the supported format and data size in the relevant manuals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. What information helps identify a suitable replacement for an installed FENA module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecord the product ID, module type, drive control unit, firmware revision, and active protocol. Compare the replacement against ABB's approved option list for that drive configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. Can I use a long Ethernet cable at 100 Mbps in a drive cabinet?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe stated maximum segment length is 100 m. Check cable quality, routing, connector integrity, and the network equipment. Electrical noise and poor installation can still affect communication within the specified distance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e5. What should I test after changing the communication protocol?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eVerify controller recognition, profile selection, data mapping, command authority, reference scaling, and feedback values. Test the application's permitted operating states before returning the drive to normal production.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/FENA-11.png?v=1792392306\" alt=\"\"\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":67665538810038,"sku":"FENA-11","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/FENA-11-1.jpg?v=1792395319","url":"https:\/\/www.plcsparehub.com\/products\/3aua0000089107-fena-11-abb-fieldbus-kit-ethernet-interface","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}