{"product_id":"350901-040-bently-nevada-htvas-cable-vibration-sensor-interconnect","title":"350901-040 Bently Nevada HTVAS Cable | Vibration Sensor Interconnect","description":"\u003ch2\u003eBently Nevada 350901-040 HTVAS Field Interconnect Cable\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e 350901-040\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Bently Nevada\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e HTVAS Field Interconnect Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Series:\u003c\/strong\u003e 350901-AAA\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecified Cable Length:\u003c\/strong\u003e 40 ft (12.2 m)\u003c\/p\u003e\n\u003ch3\u003eProduct Overview | High-Temperature Vibration Measurement Connection\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 350901-040 is an HTVAS Field Interconnect Cable configuration with a specified length of 40 ft (12.2 m). It is intended for use within a compatible high-temperature vibration measurement installation, where cable construction, routing, electrical characteristics, and hazardous-area requirements must be considered together.\u003c\/p\u003e\n\u003cp\u003eThe specified integral cable uses 300-series stainless steel mineral insulation with a stainless steel overbraid. This construction is intended for demanding industrial installations where mechanical protection and high-temperature measurement-system requirements are important. The minimum recommended bend radius is 51 mm (2.0 in).\u003c\/p\u003e\n\u003cp\u003eFor replacement projects, verify the installed sensor or system configuration, required cable length, electrical interface, temperature envelope, and applicable hazardous-area approval before ordering. The cable part number alone does not establish compatibility with every HTVAS sensor or monitoring arrangement.\u003c\/p\u003e\n\u003ch3\u003e01 | Ordering Code — Configuration Tree\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering format:\u003c\/strong\u003e 350901-AAA\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e350901\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eBase ordering series for the HTVAS field interconnect cable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAAA — Cable Length\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e040\u003c\/strong\u003e = 40 ft (12.2 m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplete ordered model\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e350901-040\u003c\/strong\u003e = HTVAS Field Interconnect Cable, 40 ft (12.2 m).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSelection note:\u003c\/strong\u003e Confirm the cable routing distance and required service loop before selecting the length. Do not reduce the specified bend radius to accommodate a tight installation.\u003c\/p\u003e\n\u003ch3\u003e02 | Cable Construction and Mechanical Limits\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCable Model\u003c\/th\u003e\n\u003ctd\u003e350901-040\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCable Length\u003c\/th\u003e\n\u003ctd\u003e40 ft (12.2 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCable Diameter\u003c\/th\u003e\n\u003ctd\u003e6.35 ± 1.27 mm (0.25 ± 0.05 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCable Construction\u003c\/th\u003e\n\u003ctd\u003e300-series stainless steel mineral-insulated integral cable with stainless steel overbraid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMinimum Bend Radius\u003c\/th\u003e\n\u003ctd\u003e51 mm (2.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum System Cable Length\u003c\/th\u003e\n\u003ctd\u003e305 m (1,000 ft), as specified in the supplied system data; confirm the applicable system configuration and cable requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGrounding\u003c\/th\u003e\n\u003ctd\u003eCase isolated, according to the supplied electrical specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e03 | Electrical and Measurement-System Performance\u003c\/h3\u003e\n\u003cp\u003eThe following values were supplied with the product information. Several describe the associated HTVAS sensor or measurement system rather than the passive cable alone. Confirm their applicability to the exact sensor, electronics, cable configuration, and approval variant before using them as acceptance criteria.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e-18 to -30 V DC; -18 to -28 V DC for hazardous-area approval options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eQuiescent Current\u003c\/th\u003e\n\u003ctd\u003e6 mA nominal, no load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTransverse Sensitivity\u003c\/th\u003e\n\u003ctd\u003eLess than 5% of axial sensitivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmplitude Linearity\u003c\/th\u003e\n\u003ctd\u003e±1% to 4,900 m\/s² (500 g) peak overall acceleration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounted Resonant Frequency\u003c\/th\u003e\n\u003ctd\u003eGreater than 15 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVelocity Output Sensitivity\u003c\/th\u003e\n\u003ctd\u003e3.94 mV\/mm\/s (100 mV\/in\/s) ±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFrequency Response\u003c\/th\u003e\n\u003ctd\u003e40 Hz to 1 kHz (2,400 to 60,000 cpm), ±5%, with 305 m (1,000 ft) of cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExtended Frequency Response\u003c\/th\u003e\n\u003ctd\u003e25 Hz to 2 kHz (1,500 to 120,000 cpm), ±3 dB, with 305 m (1,000 ft) of cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput Bias Voltage\u003c\/th\u003e\n\u003ctd\u003e-10.0 ± 2.0 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVelocity Range\u003c\/th\u003e\n\u003ctd\u003e1,270 mm\/s (50 in\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBroadband Noise Floor\u003c\/th\u003e\n\u003ctd\u003e0.05 mm\/s RMS (0.002 in\/s RMS) maximum, 5 Hz to 2 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e04 | Extended-Temperature Performance\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSensor Temperature Range\u003c\/th\u003e\n\u003cth\u003eElectronics Temperature Range\u003c\/th\u003e\n\u003cth\u003eSpecified System Sensitivity Stability\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e-54°C to +399°C (-65°F to +750°F)\u003c\/td\u003e\n\u003ctd\u003e-54°C to +125°C (-65°F to +257°F)\u003c\/td\u003e\n\u003ctd\u003eOutput remains within ±10% of 3.94 mV\/mm\/s (100 mV\/in\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-54°C to +482°C (-65°F to +900°F)\u003c\/td\u003e\n\u003ctd\u003e-54°C to +125°C (-65°F to +257°F)\u003c\/td\u003e\n\u003ctd\u003eOutput remains within ±15% of 3.94 mV\/mm\/s (100 mV\/in\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e These extended-temperature figures describe the specified measurement-system performance, not a standalone temperature rating for every section of the cable assembly. Verify the applicable sensor, electronics, cable, termination, and installation limits before use.\u003c\/p\u003e\n\u003ch3\u003e05 | Hazardous-Area Approval Information\u003c\/h3\u003e\n\u003cp\u003eThe supplied documentation lists the following hazardous-area classification entries for associated approval options. The exact approval depends on the approved product configuration. Confirm the manufacturer's certification documentation and the markings on the actual supplied assembly before installation in a classified area.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ecNRTLus:\u003c\/strong\u003e Approval designation listed in the supplied specifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntrinsic safety:\u003c\/strong\u003e Ex ia IIC and Ex ia IIB entries for Zone 0 applications, with temperature-class and ambient-temperature notation requiring verification against the original certificate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNorth American Zone classification:\u003c\/strong\u003e Class I, Zone 0, AEx ia IIC and AEx ia IIB entries are listed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDivision classification:\u003c\/strong\u003e Class I, Division 1 entries for Groups A, B, C and D, and additional entries for Groups C and D; Class II, Division 1, Groups E, F and G; and Class III, Division 1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDivision 2:\u003c\/strong\u003e Class I, Division 2 entries for Groups A, B, C and D, with a separate entry for Groups C and D.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncreased safety:\u003c\/strong\u003e Ex ec IIC and Class I, Zone 2, AEx ec IIC entries are listed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe supplied text includes temperature-class strings such as “T4\/T492 °C,” which may combine separate marking elements or contain a formatting error. Do not reproduce that string as a verified certification label without checking the original certificate. Approval requirements also depend on the complete installed system, wiring method, associated equipment, and site regulations.\u003c\/p\u003e\n\u003ch3\u003e06 | Suitable Equipment and Application Scenarios\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-temperature machinery monitoring:\u003c\/strong\u003e Field cable routing in compatible vibration measurement installations where the sensor operates in an elevated-temperature environment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRotating equipment condition monitoring:\u003c\/strong\u003e Connection between a compatible vibration sensor assembly and its associated measurement electronics or monitoring system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial process equipment:\u003c\/strong\u003e Applications where stainless steel overbraid and mineral-insulated cable construction are required by the installation design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous-area installations:\u003c\/strong\u003e Applications only where the exact product configuration and complete measurement loop meet the site's approved hazardous-area requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance and replacement projects:\u003c\/strong\u003e Replacement of an existing 350901-series cable after confirming length, termination, sensor interface, routing, and certification requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDo not infer a specific machine model, sensor connector, or monitor compatibility from the cable series name alone. Verify the equipment bill of materials and manufacturer's interconnection drawing before ordering.\u003c\/p\u003e\n\u003ch3\u003e07 | Installation Checks for Reliability\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify cable length.\u003c\/strong\u003e Confirm that 40 ft (12.2 m) reaches the installation point while allowing suitable routing and strain relief.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintain the bend radius.\u003c\/strong\u003e Keep cable bends at or above the specified 51 mm (2.0 in) minimum radius. Avoid sharp bends, kinks, and repeated flexing at the termination.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect the overbraid.\u003c\/strong\u003e Look for crushed areas, cuts, broken strands, or other damage that may indicate mechanical stress.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtect the termination.\u003c\/strong\u003e Route and secure the cable so that vibration, movement, and cable weight do not load the electrical connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck electrical requirements.\u003c\/strong\u003e Confirm the applicable supply range and hazardous-area voltage restrictions for the complete measurement system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify grounding and isolation.\u003c\/strong\u003e Follow the manufacturer's wiring drawing for the case-isolated arrangement. Do not add an unapproved grounding path that changes the intended installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValidate hazardous-area compliance.\u003c\/strong\u003e Confirm the actual certification, temperature marking, cable routing method, and associated equipment requirements before energizing the system.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003e08 | Field Diagnostic Matrix\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eObserved Symptom\u003c\/th\u003e\n\u003cth\u003ePossible Cause\u003c\/th\u003e\n\u003cth\u003eRecommended Diagnostic Action\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo vibration signal\u003c\/td\u003e\n\u003ctd\u003eMissing supply, incorrect wiring, open circuit, incompatible termination, or sensor\/electronics fault\u003c\/td\u003e\n\u003ctd\u003eVerify the specified supply at the appropriate test point, inspect the complete wiring path, and test the sensor and electronics according to the manufacturer's procedure.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal amplitude is lower than expected\u003c\/td\u003e\n\u003ctd\u003eConnection resistance, damaged cable, incorrect sensitivity configuration, or a fault elsewhere in the measurement chain\u003c\/td\u003e\n\u003ctd\u003eCompare the measured output with the system's specified sensitivity. Inspect connections and cable condition, then isolate components methodically.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntermittent readings during machine operation\u003c\/td\u003e\n\u003ctd\u003eMechanical strain, damaged conductor or termination, vibration-induced connection movement, or electromagnetic interference\u003c\/td\u003e\n\u003ctd\u003eInspect cable supports and terminations, check for over-tight bends or mechanical damage, and compare the signal during controlled operating conditions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnexpected noise or unstable baseline\u003c\/td\u003e\n\u003ctd\u003eGrounding or isolation issue, electrical interference, incorrect wiring, or a problem in the sensor\/electronics chain\u003c\/td\u003e\n\u003ctd\u003eReview the approved wiring diagram, confirm the intended case isolation, and compare signal behavior with the equipment operating and stopped where safe.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement changes as temperature rises\u003c\/td\u003e\n\u003ctd\u003eOperation outside the applicable component temperature range, termination stress, or temperature-related behavior elsewhere in the system\u003c\/td\u003e\n\u003ctd\u003eRecord sensor and electronics temperatures separately. Compare the results with the specified system sensitivity stability and verify the limits for each component.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal response differs from expected frequency behavior\u003c\/td\u003e\n\u003ctd\u003eIncorrect system configuration, cable or sensor mismatch, installation resonance, or an issue in the monitoring channel\u003c\/td\u003e\n\u003ctd\u003eConfirm the exact sensor model and total cable arrangement. Review the applicable frequency-response limits and compare results with a known-good channel or approved test method.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic scope:\u003c\/strong\u003e The field interconnect cable is not a standalone diagnostic instrument and does not independently generate vibration measurements or alarm codes. Troubleshooting must consider the cable, sensor, electronics, power supply, wiring, and monitoring channel as one measurement chain.\u003c\/p\u003e\n\u003ch3\u003e09 | Global PLC Spare HUB's Insight\u003c\/h3\u003e\n\u003cblockquote\u003eFor the 350901-040, correct selection depends on more than its 40 ft length. The cable must fit the actual HTVAS system configuration, preserve the required routing and bend radius, and comply with the electrical and hazardous-area requirements of the installation.\u003c\/blockquote\u003e\n\u003cp\u003eFor a maintenance replacement, start by comparing the complete ordering code and the installed cable's termination arrangement. Then verify the equipment documentation, cable route, operating temperatures, supply requirements, and certification markings. This sequence helps avoid purchasing a cable that has the correct length but is unsuitable for the installed measurement chain.\u003c\/p\u003e\n\u003cp\u003eWhere vibration readings are abnormal, do not immediately attribute the issue to the cable. Check power, connections, isolation, sensor condition, and monitoring-channel configuration in a controlled sequence. This is particularly important when the system operates over a wide temperature range or in a classified hazardous area.\u003c\/p\u003e\n\u003ch3\u003e10 | Frequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How do I determine whether a 40 ft cable is long enough for my installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMeasure the intended route rather than the straight-line distance. Include routing around hot surfaces, mechanical supports, enclosure entry points, service loops, and strain-relief requirements. Keep all bends within the specified minimum radius and confirm that the complete system's cable-length requirements are satisfied.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can the cable's temperature range be used as the allowable temperature for the entire assembly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The supplied extended-temperature figures refer to system sensitivity stability under stated sensor and electronics temperature conditions. Cable, terminations, sensor, electronics, and mounting hardware can have different limits. Verify each component's rating against the actual operating conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What information should I provide when requesting a replacement quote?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eProvide the full part number 350901-040, photographs of the existing cable and terminations, the associated sensor and electronics model numbers, required cable length, operating temperature range, and hazardous-area classification. This information helps establish whether the offered cable matches the installed configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: If the cable passes a continuity test, can I assume the vibration measurement system is functioning correctly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Continuity alone does not verify insulation integrity, correct wiring, grounding and isolation, sensor operation, sensitivity, frequency response, or hazardous-area suitability. Use the manufacturer's complete diagnostic procedure and appropriate test equipment to assess the measurement chain.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What should I verify before using this cable in a hazardous area?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConfirm the approval certificate for the exact product configuration, the actual equipment nameplate markings, the applicable temperature class and ambient limits, the associated electronics, and the installation wiring method. Do not rely on a general series description or an unverified certification summary as proof of compliance.\u003c\/p\u003e\n\u003ch3\u003e11 | Warranty, Shipping and Order Support\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct:\u003c\/strong\u003e Bently Nevada 350901-040 HTVAS Field Interconnect Cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12-month warranty, subject to the seller's written warranty terms and confirmation of the supplied item's condition and coverage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Methods:\u003c\/strong\u003e FedEx, UPS, and DHL, subject to destination and service availability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch Target:\u003c\/strong\u003e 24–48 hours after order and payment confirmation, subject to stock availability and order processing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder Verification:\u003c\/strong\u003e Confirm cable length, termination, system compatibility, and required hazardous-area approval before purchase.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eContact Global PLC Spare HUB to request a quote for Bently Nevada 350901-040. Include the installed system details and application requirements so that configuration, availability, warranty coverage, and shipping arrangements can be checked before ordering.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":67644553986230,"sku":"350901-040","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/350901.jpg?v=1792049626","url":"https:\/\/www.plcsparehub.com\/products\/350901-040-bently-nevada-htvas-cable-vibration-sensor-interconnect","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}