{"product_id":"330905-05-25-10-02-05-bently-nevada-nsv-vibration-probe-sensor","title":"330905-05-25-10-02-05 Bently Nevada NSv Vibration Probe Sensor","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #1a56db;\"\u003e\u003cstrong\u003e330905-05-25-10-02-05\u003c\/strong\u003e\u003c\/span\u003e is a high-performance \u003cspan style=\"color: #1a56db;\"\u003e\u003cstrong\u003e3300 NSv\u003c\/strong\u003e\u003c\/span\u003e proximity probe engineered for specialized industrial measurements. It provides reliable shaft vibration monitoring in restricted target areas where standard probes fall short.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConfiguration Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul style=\"list-style-type: none; padding-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Model:\u003c\/strong\u003e \u003cspan style=\"color: #1a56db;\"\u003e\u003cstrong\u003e330905\u003c\/strong\u003e\u003c\/span\u003e (3300 NSv Probe, M10X1 thread, armor-free)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnthreaded Length Option:\u003c\/strong\u003e -05 (50 mm unthreaded section)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverall Case Length Option:\u003c\/strong\u003e -25 (250 mm total case length)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Length Option:\u003c\/strong\u003e 10 (1.0 meter cable length)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector \u0026amp; Cable Option:\u003c\/strong\u003e 02 (Miniature coaxial ClickLoc connector with standard cable)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAgency Approval Option:\u003c\/strong\u003e -05 (Multiple hazardous area approvals)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications Matrix\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f3f4f6;\"\u003e\n\u003cth style=\"border: 1px solid #d1d5db; padding: 8px; text-align: left;\"\u003eParameter Category\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #d1d5db; padding: 8px; text-align: left;\"\u003eEngineering Metric\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d1d5db; padding: 8px;\"\u003e\u003cstrong\u003eLinear Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d1d5db; padding: 8px;\"\u003e1.5 mm (60 mils) spanning from 0.25 to 1.75 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d1d5db; padding: 8px;\"\u003e\u003cstrong\u003eIncremental Scale Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d1d5db; padding: 8px;\"\u003e7.87 V\/mm (200 mV\/mil) nominal output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d1d5db; padding: 8px;\"\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d1d5db; padding: 8px;\"\u003e0 to 10 kHz (+0, -3 dB) with up to 305 m field wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d1d5db; padding: 8px;\"\u003e\u003cstrong\u003eElectrical Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d1d5db; padding: 8px;\"\u003eProbe RPROBE at 4.2 ± 0.5 Ω (Center to Outer Conductor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d1d5db; padding: 8px;\"\u003e\u003cstrong\u003eThermal Operating Limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d1d5db; padding: 8px;\"\u003e-52°C to +177°C for both operation and storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eTarget Metrics \u0026amp; Mechanical Parameters\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul style=\"list-style-type: none; padding-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended Target Size:\u003c\/strong\u003e Minimum 13 mm (0.5 in) flat target diameter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended Gap Setting:\u003c\/strong\u003e 1.0 mm (40 mils) initial static gap\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCase Thread Specification:\u003c\/strong\u003e M10x1 with a maximum 15 mm thread engagement\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Torque Limits:\u003c\/strong\u003e Finger tight recommended; 0.56 N•m maximum limit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility \u0026amp; Selection Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWhen selecting proximity sensors for tight clearances or specialized compressors, comparing technical parameters ensures optimal loop performance. Review the engineering alternative below:\u003c\/p\u003e\n\u003cul style=\"list-style-type: none; padding-left: 0;\"\u003e\n\u003cli\u003eAlternative Model Link: \u003ca href=\"https:\/\/www.plcsparehub.com\/products\/330905-05-13-05-12-00-3300-nsv-proximity-sensor-by-bently-nevada\" style=\"color: #1a56db; text-decoration: underline;\"\u003e\u003cstrong\u003e330905-05-13-05-12-00\u003c\/strong\u003e\u003c\/a\u003e – Features a shorter 130 mm case length configuration variant designed for restricted housing depths.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eWarranty \u0026amp; Logistics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eEvery unit is backed by a full 12-month factory warranty. We dispatch orders within 24 to 48 hours using secure international carriers including FedEx, UPS, and DHL.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Scenarios \u0026amp; Diagnostic Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eEngineers deploy this sensor in high-pressure process compressors, specialized gearboxes, and small-diameter turbomachinery. The NSv design excels at detecting synchronous vibration anomalies, shaft centerline shifts, and incipient rub conditions before mechanical breakdown happens.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eOur engineering team installed the \u003cspan style=\"color: #1a56db;\"\u003e\u003cstrong\u003e330905-05-25-10-02-05\u003c\/strong\u003e\u003c\/span\u003e on a high-speed centrifugal process compressor experiencing sub-synchronous vibration spikes. Because of the compressor's restrictive internal geometry, standard 8mm probes caused side-view distortion. Switching to this specialized NSv configuration normalized the signal response, allowing accurate vector analysis and preventing an unplanned plant outage.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why is an NSv probe required instead of a standard 3300 XL probe?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: NSv probes feature modified side-view characteristics built for small shafts or restricted pocket clearances where standard probes distort linear outputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What field cable type should technicians use for installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Always use a 3-conductor shielded triad cable with a maximum length of 305 meters to maintain signal integrity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the Viton O-ring function under pressure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The O-ring seals differential pressure between the probe tip and case assembly up to specified operational limits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the ideal gap voltage for initial commissioning?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Target a 1.0 mm static gap setting, which generally correlates to approximately -6 to -8 Vdc depending on the power supply.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How should maintenance teams handle tight bend radii during routing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Maintain a minimum bend radius of 25.4 mm on the coaxial cable to prevent internal conductor fracture or impedance shifts.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330905_Installed_Connector_Protectors_1f060935-a1f6-44ce-bb4b-f2a1559e5b86.png?v=1784692061\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013975990454,"sku":"330905-05-25-10-02-05","price":160.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330905-00-16-10-02-05_b7d6c4df-6113-4aa6-969a-741e803b9af4.jpg?v=1789550504","url":"https:\/\/www.plcsparehub.com\/products\/330905-05-25-10-02-05-bently-nevada-nsv-vibration-probe-sensor","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}