{"product_id":"330905-00-25-05-01-00-bently-nevada-3300-nsv-proximity-probe","title":"330905-00-25-05-01-00 | Bently Nevada 3300 NSv Proximity Probe","description":"\u003ch3\u003e\u003cstrong\u003eTechnical Engineering Brief\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #0051ba;\"\u003eBently Nevada 330905-00-25-05-01-00\u003c\/span\u003e\u003c\/strong\u003e is a specialized eddy-current transducer belonging to the high-density \u003cstrong\u003e\u003cspan style=\"color: #0051ba;\"\u003e3300 NSv\u003c\/span\u003e\u003c\/strong\u003e proximity probe series.\u003c\/p\u003e\n\u003cp\u003eDesigned for narrow installation paths and small target profiles, this non-contacting sensor measures static gaps and dynamic displacement profiles effectively.\u003c\/p\u003e\n\u003cp\u003eThe M10X1 threaded stainless steel body houses an advanced polyphenylene sulfide tip, delivering superior chemical resistance for process compressor deployments.\u003c\/p\u003e\n\u003cp\u003eBy translating micro-inch mechanical movements into linear DC voltage shifts, this hardware ensures precise vibration data capture under strict space limitations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eModel Configuration Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e330905\u003c\/strong\u003e ── Core Proximity Probe Type\n\u003cul\u003e\n\u003cli\u003e↳ Series Type: \u003cstrong\u003e\u003cspan style=\"color: #0051ba;\"\u003e3300 NSv\u003c\/span\u003e\u003c\/strong\u003e Transducer (Optimized for small targets)\u003c\/li\u003e\n\u003cli\u003e↳ Thread Profile: M10 x 1 metric thread\u003c\/li\u003e\n\u003cli\u003e↳ Armor Configuration: Unarmored standard coaxial cable design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00\u003c\/strong\u003e ── Unthreaded Length Option\n\u003cul\u003e\n\u003cli\u003e↳ Dimension: 00 mm unthreaded sleeve area (Fully threaded casing)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e25\u003c\/strong\u003e ── Overall Case Length Option\n\u003cul\u003e\n\u003cli\u003e↳ Dimension: 250 mm total metallic housing length\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e05\u003c\/strong\u003e ── Total Length Option\n\u003cul\u003e\n\u003cli\u003e↳ Dimension: 0.5 meter (20 inches) physical integration length\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e01\u003c\/strong\u003e ── Connector \u0026amp; Cable-Type Option\n\u003cul\u003e\n\u003cli\u003e↳ Variant: Miniature coaxial ClickLoc connector equipped with integrated connector protector\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00\u003c\/strong\u003e ── Agency Approval Option\n\u003cul\u003e\n\u003cli\u003e↳ Status: Base variant, no localized hazardous zone certification tags required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Architecture \u0026amp; Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBrand: \u003cstrong\u003e\u003cspan style=\"color: #0051ba;\"\u003eBently Nevada\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eModel: \u003cstrong\u003e\u003cspan style=\"color: #0051ba;\"\u003e330905-00-25-05-01-00\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSeries: \u003cstrong\u003e\u003cspan style=\"color: #0051ba;\"\u003e3300 NSv\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eComponent Type: Non-Contact Eddy Current Proximity Transducer\u003c\/li\u003e\n\u003cli\u003eMeasurement Linear Range: 1.5 mm (60 mils) total displacement window\u003c\/li\u003e\n\u003cli\u003eOperational Gap Limits: Commences at 0.25 mm (10 mils) up to 1.75 mm (70 mils) from the target face\u003c\/li\u003e\n\u003cli\u003eElectrical Signaling Range: Corresponds linearly from -1 V DC to -13 V DC output levels\u003c\/li\u003e\n\u003cli\u003eRecommended Target Gap: Set at 1.0 mm (40 mils) installation distance\u003c\/li\u003e\n\u003cli\u003eIncremental Scale Factor: 7.87 V\/mm (200 mV\/mil) +12.5%\/-20% accuracy profile\u003c\/li\u003e\n\u003cli\u003eDeviation From Best Fit Straight Line: Within ±0.06 mm (±2.3 mils) limits\u003c\/li\u003e\n\u003cli\u003eFrequency Response Bandwidth: 0 to 10 kHz; +0, -3 dB typical signal attenuation\u003c\/li\u003e\n\u003cli\u003eFlat Target Diameter Threshold: Minimum 8.9 mm (0.35 in); Recommended minimum 13 mm (0.5 in)\u003c\/li\u003e\n\u003cli\u003eNominal Loop DC Resistance: 4.0 ohms ± 0.5 ohms measured center conductor to shield\u003c\/li\u003e\n\u003cli\u003eExtension Cable Capacitance Index: 69.9 pF\/meter (21.3 pF\/ft) typical value\u003c\/li\u003e\n\u003cli\u003eHousing Metallic Composition: AISI 304 austenitic stainless steel\u003c\/li\u003e\n\u003cli\u003eTip Material Compounding: High-stability Polyphenylene Sulfide polymer\u003c\/li\u003e\n\u003cli\u003eInternal Insulation Wrap: Fluoroethylene propylene insulated 75-ohm coaxial design\u003c\/li\u003e\n\u003cli\u003eHigh-Pressure Process Sealing: Viton O-ring internal differential pressure barrier\u003c\/li\u003e\n\u003cli\u003eMinimum Cable Bend Radius: 25.4 mm (1.0 in) static physical routing radius\u003c\/li\u003e\n\u003cli\u003eRecommended Thread Torque: 7.5 N·m (66 in·lb) under standard mounting configurations\u003c\/li\u003e\n\u003cli\u003eConnector Finger Tightening Limits: 0.56 N·m (5 in·lb) maximum rated terminal threshold\u003c\/li\u003e\n\u003cli\u003eStandard Temperature Limits: Sustains internal components across a -52 °C to +177 °C operational spectrum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eHost Equipment Interoperability\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #0051ba;\"\u003eBently Nevada 330905-00-25-05-01-00\u003c\/span\u003e\u003c\/strong\u003e functions as a legacy-compatible analog capture mechanism, pairing directly with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBently Nevada \u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/3300-xl-probe-and-sensor\"\u003e3300 XL NSv Proximitor Sensors\u003c\/a\u003e (5-meter or 7-meter baseline calibrations)\u003c\/li\u003e\n\u003cli\u003eBently Nevada \u003ca href=\"https:\/\/www.plcsparehub.com\/products\/3500-40m-01-00-4-channel-proximitor-monitor-bently-nevada\"\u003e3500\/40M\u003c\/a\u003e Proximitor Monitor Modules\u003c\/li\u003e\n\u003cli\u003eBently Nevada \u003ca href=\"https:\/\/www.plcsparehub.com\/products\/3500-42m-09-00-bently-nevada-proximitor-seismic-monitor\"\u003e3500\/42M\u003c\/a\u003e Displacement Monitors\u003c\/li\u003e\n\u003cli\u003eBently Nevada 3300 RAM legacy proximity extension paths\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTarget Field Implementations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRadial vibration monitoring on small-diameter high-speed turbocharger rotor shafts.\u003c\/li\u003e\n\u003cli\u003eAxial thrust position tracking inside compact centrifugal gas process compressors.\u003c\/li\u003e\n\u003cli\u003eStructural oil-film clearance measurements within highly corrosive chemical blending pumps.\u003c\/li\u003e\n\u003cli\u003ePosition tracking applications where the probe body is exposed to tight side-view metal constraints.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eNetwork Diagnostics \u0026amp; Metrology Verification\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDC Resistance Cross-Checking: Measuring the 4.0-ohm nominal loop baseline helps identify shorted coils or missed shields early.\u003c\/li\u003e\n\u003cli\u003eHigh-Frequency Attenuation Audit: Technicians monitor the 10 kHz rolloff profile to check signal degradation on long field runs.\u003c\/li\u003e\n\u003cli\u003eScale Factor Verification: Tracks deviation from the straight line calibration over the 1.5 mm range to prevent monitoring errors.\u003c\/li\u003e\n\u003cli\u003eClickLoc Connection Integrity: Integrated connector protectors isolate the coaxial link from fluid ingress and physical loosening.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #0051ba;\"\u003eBently Nevada 330905-00-25-05-01-00\u003c\/span\u003e\u003c\/strong\u003e is a problem-solver for tight spaces.\u003c\/p\u003e\n\u003cp\u003eIts enhanced side-view characteristics prevent cross-talk errors when mounting close to surrounding metal walls safely.\u003c\/p\u003e\n\u003cp\u003eThe 250 mm fully-threaded case offers deep reach into internal bearing housings easily.\u003c\/p\u003e\n\u003cp\u003eMeanwhile, the FEP-insulated 0.5-meter cable layout withstands harsh chemical atmospheres reliably over long service intervals.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCross-Model Selection Analysis\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e330905-00-25-05-01-00\u003c\/strong\u003e (Current Model): Features a 250 mm extra-long fully-threaded case (00 mm unthreaded sleeve) and a 0.5-meter standard cable lead with ClickLoc terminal protection. It is optimized for deep machine casings with restricted target clearances.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.plcsparehub.com\/products\/330905-00-08-05-12-05-nsv-series-sensor-bently-nevada-3300-probe\"\u003e\u003cstrong\u003e330905-00-08-05-12-05\u003c\/strong\u003e\u003c\/a\u003e: Features an 80 mm short fully-threaded case, 0.5-meter cable length, and alternative connector profiles. It fits compact housings where long probe cases are not required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Application Guidance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSmall Shaft Scaling: Adjust your scale factor math if monitoring shafts under 13 mm, or close the gap slightly to reduce scaling errors.\u003c\/li\u003e\n\u003cli\u003eChemical Environment Rules: The PPS and Viton sealing layers handle corrosive gas processes well, making this module a reliable choice for compressor upgrades.\u003c\/li\u003e\n\u003cli\u003eSystem Integration Matching: Verify that your combined probe and extension cable length matches the 5-meter or 7-meter configuration required by your Proximitor sensor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eLogistical Logistics \u0026amp; Warranty Terms\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStandard Packaging: Factory-sealed anti-static shielding box with protective contact caps.\u003c\/li\u003e\n\u003cli\u003eExpress Courier Distribution: Priority global air freight fulfilled via FedEx, UPS, or DHL networks.\u003c\/li\u003e\n\u003cli\u003eProcessing Lead Time: Guaranteed automated packaging and dispatch completed within 24 to 48 hours.\u003c\/li\u003e\n\u003cli\u003eExtended Coverage: Backed by a comprehensive 12-month industrial replacement warranty covering functional performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAdvanced Engineering FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy do axial position measurements shift unexpectedly when this probe is installed on small-diameter shafts?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShafts under 13 mm do not cover the eddy-current field completely, which changes the scale factor values.\u003c\/p\u003e\n\u003cp\u003eTo correct this variation, reduce the physical gap distance slightly to focus the sensing area better.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat field advantage does the 3300 NSv series offer over older legacy 3300 RAM proximity components?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe NSv probe uses advanced PPS polymers to improve chemical resistance across aggressive environments.\u003c\/p\u003e\n\u003cp\u003eThis compounding prevents target face breakdown inside process compressor systems significantly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I install this specific 250 mm long probe body without any external mechanical support sleeves?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, long 250 mm probe casings should be supported across their length to prevent physical bending issues.\u003c\/p\u003e\n\u003cp\u003eUnsupported installations risk severe fatigue failures caused by structural resonance and process fluid flows.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow can maintenance teams quickly check for a broken signal path without removing the probe from its mount?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDisconnect the ClickLoc terminal and measure the center-to-shield loop resistance using a multimeter.\u003c\/p\u003e\n\u003cp\u003eA reading falling completely outside the 4.0 ohms ± 0.5 ohms window flags an electrical path failure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the connector protector pre-installed on this specific model option?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe protector seals the miniature coaxial connection against moisture, oil, and external airborne debris.\u003c\/p\u003e\n\u003cp\u003eThis preventative enclosure blocks signal distortion from high-humidity atmospheres during long-term machine operation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProcurement Guidance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAudit Casing Clearance Depth: Measure your internal housing clearances to ensure the 250 mm threaded length fits without contacting internal components.\u003c\/li\u003e\n\u003cli\u003eVerify Extension Cable Capacitance: Ensure any existing field wiring matches the 69.9 pF\/m specification to prevent signal attenuation at high frequencies.\u003c\/li\u003e\n\u003cli\u003eCheck Target Material Specs: These sensors are calibrated for standard ferromagnetic targets. Confirm your metallurgy requirements before finalizing your order.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330901-330910_432da41b-a3bf-4c98-a960-7a1ed65c995c.png?v=1782895913\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45014036119734,"sku":"330905-00-25-05-01-00","price":103.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330905_7_762a3aae-c84a-497f-9bcf-7f2168ea64dc.jpg?v=1783331177","url":"https:\/\/www.plcsparehub.com\/products\/330905-00-25-05-01-00-bently-nevada-3300-nsv-proximity-probe","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}