{"product_id":"330904-00-15-05-12-00-bently-nevada-3300-nsv-proximity-probe-quote","title":"330904-00-15-05-12-00 Bently Nevada 3300 NSv Proximity Probe Quote","description":"\u003ch3\u003e\u003cb\u003eTransducer Architecture \u0026amp; Engineering Role: \u003cspan style=\"color: #0056b3;\"\u003e\u003cb\u003e330904-00-15-05-12-00\u003c\/b\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cb\u003eBently Nevada 330904-00-15-05-12-00\u003c\/b\u003e\u003c\/span\u003e is an armored eddy-current transducer engineered within the \u003cspan style=\"color: #0056b3;\"\u003e\u003cb\u003e3300 NSv\u003c\/b\u003e\u003c\/span\u003e (Narrow Side-View) proximity probe family. Designed specifically for centrifugal air compressors, refrigeration compressors, and high-speed fluid-film bearing machines with tight radial clearances, this probe delivers high-resolution shaft vibration and axial thrust position measurements. Its enhanced polyphenylene sulfide (PPS) tip and chemical-resistant \u003cb\u003eFluidLoc\u003c\/b\u003e coaxial cable provide superior durability in harsh process gas environments while maintaining backward mechanical and electrical interchangeability with legacy \u003cb\u003e3300 RAM\u003c\/b\u003e systems.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003ePart Number Configuration Breakdown\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eEvery suffix segment in \u003cspan style=\"color: #0056b3;\"\u003e\u003cb\u003e330904-00-15-05-12-00\u003c\/b\u003e\u003c\/span\u003e defines exact mechanical geometry, cable length, and connector hardware:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cb\u003e330904\u003c\/b\u003e\u003c\/span\u003e — Base Model: \u003cb\u003e3300 NSv Probe\u003c\/b\u003e, \u003cb\u003eM8 × 1\u003c\/b\u003e metric thread, supplied with stainless steel armor\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003e-00\u003c\/b\u003e — Unthreaded Length Option: \u003cb\u003e0 mm\u003c\/b\u003e (fully threaded case profile)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e-15\u003c\/b\u003e — Overall Case Length Option: \u003cb\u003e150 mm\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e-05\u003c\/b\u003e — Total Cable Length Option: \u003cb\u003e0.5 meter (20 in)\u003c\/b\u003e integral 75 Ω coaxial cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e-12\u003c\/b\u003e — Connector \u0026amp; Cable Option: Miniature coaxial \u003cb\u003eClickLoc\u003c\/b\u003e connector with \u003cb\u003eFluidLoc\u003c\/b\u003e oil-blocking cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e-00\u003c\/b\u003e — Agency Approval Option: Not required (standard industrial configuration)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eElectrical, Metrology \u0026amp; Mechanical Specifications\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eVerify all transducer electrical resistance, linear range, and torque limits prior to machine case installation:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cb\u003eEngineering Domain\u003c\/b\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cb\u003eTechnical Parameter\u003c\/b\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cb\u003eSpecification Value \/ Rating\u003c\/b\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eIdentification\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eManufacturer \u0026amp; Part Number\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cb\u003eBently Nevada\u003c\/b\u003e\u003c\/span\u003e \u003cspan style=\"color: #0056b3;\"\u003e\u003cb\u003e330904-00-15-05-12-00\u003c\/b\u003e\u003c\/span\u003e (\u003cspan style=\"color: #0056b3;\"\u003e\u003cb\u003e3300 NSv\u003c\/b\u003e\u003c\/span\u003e Series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eMetrological Span\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eLinear Measurement Range\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003e1.5 mm (60 mils)\u003c\/b\u003e total span: \u003cb\u003e0.25 to 1.75 mm (10 to 70 mils)\u003c\/b\u003e (~ -1 to -13 Vdc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eMetrological Span\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eRecommended Gap \u0026amp; Scale Factor\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003e1.0 mm (40 mils)\u003c\/b\u003e nominal gap | \u003cb\u003e7.87 V\/mm (200 mV\/mil)\u003c\/b\u003e +12.5% \/ -20% ISF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eSignal Fidelity\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eLinearity (DSL) \u0026amp; Frequency Response\u003c\/td\u003e\n\u003ctd\u003eDSL \u003cb\u003e\u0026lt; ±0.06 mm (±2.3 mils)\u003c\/b\u003e | \u003cb\u003e0 to 10 kHz\u003c\/b\u003e (+0, -3 dB up to 305 m field wire)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eElectrical Loop\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eProbe DC Resistance (0.5 m length)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003e4.0 ± 0.5 Ω\u003c\/b\u003e (center conductor to outer shield R\u003csub\u003ePROBE\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eExtension \u0026amp; Wiring\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eExtension Cable \u0026amp; Field Triad Specs\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003e0.220 Ω\/m\u003c\/b\u003e core, \u003cb\u003e0.066 Ω\/m\u003c\/b\u003e shield, \u003cb\u003e69.9 pF\/m\u003c\/b\u003e | 16–24 AWG triad (305 m max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eTarget Geometry\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eMinimum Flat Target Diameter\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003e8.9 mm (0.35 in)\u003c\/b\u003e absolute min | \u003cb\u003e13 mm (0.5 in)\u003c\/b\u003e recommended min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eMaterials \u0026amp; Seal\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eTip, Case \u0026amp; Pressure Seal\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003ePPS\u003c\/b\u003e tip | \u003cb\u003eAISI 304 SST\u003c\/b\u003e case | \u003cb\u003eViton O-ring\u003c\/b\u003e differential seal | FEP 75 Ω cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eMechanical Torque\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eCase \u0026amp; ClickLoc Connector Torque\u003c\/td\u003e\n\u003ctd\u003eCase: \u003cb\u003e5.1 N·m (45 in·lb)\u003c\/b\u003e rec \/ \u003cb\u003e7.3 N·m (65 in·lb)\u003c\/b\u003e max | ClickLoc: Finger tight (\u003cb\u003e0.56 N·m\u003c\/b\u003e max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eMechanical Limits\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eThread Engagement \u0026amp; Bend Radius\u003c\/td\u003e\n\u003ctd\u003eMax thread engagement: \u003cb\u003e12 mm\u003c\/b\u003e | Min cable bend radius: \u003cb\u003e25.4 mm (1.0 in)\u003c\/b\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eEnvironmental\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eOperating \u0026amp; Storage Temperature\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e-52°C to +177°C (-62°F to +351°F)\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cb\u003eModel Selection Comparison \u0026amp; Engineering Guidance\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eCompare the \u003cspan style=\"color: #0056b3;\"\u003e\u003cb\u003e330904-00-15-05-12-00\u003c\/b\u003e\u003c\/span\u003e directly against the longer-cable variant \u003ca href=\"https:\/\/www.plcsparehub.com\/products\/330904-00-15-70-01-00-bently-nevada-3300-nsv-series-proximity-sensor\"\u003e\u003cb\u003e330904-00-15-70-01-00\u003c\/b\u003e\u003c\/a\u003e to ensure exact electrical system matching:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cb\u003eComparison Parameter\u003c\/b\u003e\u003c\/th\u003e\n\u003cth\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cb\u003e330904-00-15-05-12-00\u003c\/b\u003e\u003c\/span\u003e (This Model)\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.plcsparehub.com\/products\/330904-00-15-70-01-00-bently-nevada-3300-nsv-series-proximity-sensor\"\u003e\u003cb\u003e330904-00-15-70-01-00\u003c\/b\u003e\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eThread \u0026amp; Case Geometry\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003eM8 × 1\u003c\/b\u003e armored, 0 mm unthreaded, \u003cb\u003e150 mm\u003c\/b\u003e case\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003eM8 × 1\u003c\/b\u003e armored, 0 mm unthreaded, \u003cb\u003e150 mm\u003c\/b\u003e case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eTotal Probe Cable Length\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e0.5 meter (20 in)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e7.0 meters (23 ft)\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eConnector \u0026amp; Cable Type\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003e-12:\u003c\/b\u003e ClickLoc connector with \u003cb\u003eFluidLoc\u003c\/b\u003e oil-sealed cable\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003e-01:\u003c\/b\u003e Miniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eRequired Extension Cable\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eRequires \u003cb\u003e6.5 m\u003c\/b\u003e (or 4.5 m) 3300 NSv extension cable to match 7.0 m (or 5.0 m) Proximitor\u003c\/td\u003e\n\u003ctd\u003eConnects directly to a \u003cb\u003e7.0 m\u003c\/b\u003e Proximitor sensor without an extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eTechnical Selection Recommendation:\u003c\/b\u003e Choose \u003cspan style=\"color: #0056b3;\"\u003e\u003cb\u003e330904-00-15-05-12-00\u003c\/b\u003e\u003c\/span\u003e when routing probes through internal bearing housings where pressurized lube oil requires \u003cb\u003eFluidLoc\u003c\/b\u003e capillary blocking and an external junction box houses a 6.5 m extension cable. Select \u003ca href=\"https:\/\/www.plcsparehub.com\/products\/330904-00-15-70-01-00-bently-nevada-3300-nsv-series-proximity-sensor\"\u003e\u003cb\u003e330904-00-15-70-01-00\u003c\/b\u003e\u003c\/a\u003e when you want a single continuous \u003cb\u003e7.0 m\u003c\/b\u003e run directly to the Proximitor sensor without an intermediate ClickLoc junction.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eField Installation \u0026amp; Gapping Protocol\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eElectrical System Length Matching:\u003c\/b\u003e Pair this \u003cb\u003e0.5 m\u003c\/b\u003e probe strictly with a matching \u003cb\u003e3300 NSv\u003c\/b\u003e extension cable (such as 4.5 m or 6.5 m) so the combined electrical length equals the exact \u003cb\u003e5.0 m\u003c\/b\u003e or \u003cb\u003e7.0 m\u003c\/b\u003e rating stamped on your \u003cb\u003e3300 XL NSv Proximitor Sensor\u003c\/b\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eStatic Gap Calibration:\u003c\/b\u003e Thread the \u003cb\u003eM8 × 1\u003c\/b\u003e probe until the gap voltage reads approximately \u003cb\u003e-9.0 Vdc\u003c\/b\u003e (corresponding to the recommended \u003cb\u003e1.0 mm \/ 40 mils\u003c\/b\u003e mechanical gap), then lock the jam nut to \u003cb\u003e5.1 N·m (45 in·lb)\u003c\/b\u003e without exceeding \u003cb\u003e7.3 N·m\u003c\/b\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eArmor \u0026amp; Connector Protection:\u003c\/b\u003e Maintain a minimum cable bend radius of \u003cb\u003e25.4 mm (1.0 in)\u003c\/b\u003e and fasten the miniature ClickLoc connector finger-tight (never exceed \u003cb\u003e0.56 N·m \/ 5 in·lb\u003c\/b\u003e).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eScope of Supply \u0026amp; Warranty\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003e1 ×\u003c\/b\u003e \u003cspan style=\"color: #0056b3;\"\u003e\u003cb\u003eBently Nevada\u003c\/b\u003e\u003c\/span\u003e \u003cspan style=\"color: #0056b3;\"\u003e\u003cb\u003e330904-00-15-05-12-00\u003c\/b\u003e\u003c\/span\u003e 3300 NSv Proximity Probe (New \u0026amp; Original in Factory Packing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eWarranty Coverage:\u003c\/b\u003e Backed by a \u003cb\u003e12-Month\u003c\/b\u003e factory warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eField Engineering FAQ\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eQ: What diagnostic check verifies coil integrity on the 330904-00-15-05-12-00 before machine startup?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Measure DC resistance across the miniature ClickLoc center pin and outer shell using a calibrated digital multimeter; a healthy 0.5 m probe must read within 4.0 ± 0.5 ohms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eQ: Why does the -12 FluidLoc option matter in centrifugal compressor bearing housings?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: FluidLoc coaxial cable incorporates an internal sealant barrier that prevents pressurized synthetic or mineral lubricating oil from wicking through the cable strands into external junction boxes and Proximitor housings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eQ: How does target diameter affect scale factor accuracy on small-shaft axial thrust measurements?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: While the absolute minimum flat target is 8.9 mm (0.35 in), targets smaller than the recommended 13 mm (0.5 in) diameter alter the eddy-current field distribution and reduce Incremental Scale Factor; setting a slightly tighter initial gap helps compensate for this shift.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eQ: Can this 3300 NSv probe replace an older 3300 RAM probe without changing the mounting bracket?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, 3300 NSv probes and extension cables are mechanically and electrically interchangeable with legacy 3300 RAM components while offering superior chemical resistance and improved side-view clearance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eQ: What happens if a technician over-torques the M8x1 probe case or engages threads beyond 12 mm?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Exceeding the 7.3 N·m maximum case torque or threading beyond the 12 mm maximum engagement limit can distort the AISI 304 stainless steel housing, damage the internal Viton O-ring seal, or crack the PPS probe tip.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330901-330910_432da41b-a3bf-4c98-a960-7a1ed65c995c.png?v=1782895913\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013973467318,"sku":"330904-00-15-05-12-00","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/3309044_3_ec324c73-0eff-4743-8973-256fde9771a5.jpg?v=1788858940","url":"https:\/\/www.plcsparehub.com\/products\/330904-00-15-05-12-00-bently-nevada-3300-nsv-proximity-probe-quote","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}