{"product_id":"330903-00-05-70-01-05-bently-nevada-3300-nsv-sensor-probe-quick-quote","title":"330903-00-05-70-01-05 Bently Nevada 3300 NSv Sensor Probe Quick Quote","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003eBently Nevada 330903-00-05-70-01-05\u003c\/span\u003e\u003c\/b\u003e is a high-precision proximity probe belonging to the industry-standard \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003eBently Nevada 3300 NSv\u003c\/span\u003e\u003c\/b\u003e series. Engineered for tight-clearance machine applications, this eddy current transducer measures shaft vibration, position, and dynamic displacement with high accuracy. Automation and rotating machinery engineers utilize the \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003e330903-00-05-70-01-05\u003c\/span\u003e\u003c\/b\u003e in critical machinery protection systems where space constraints prevent the use of standard-size probes.\u003c\/p\u003e\n\u003cp\u003eFeaturing enhanced chemical resistance over legacy RAM probes, the Polyphenylene sulfide (PPS) tip and AISI 304 stainless steel case withstand corrosive hydrocarbon environments. The integrated Viton O-ring seals differential pressure between the tip and case, preventing process fluid leakage in high-pressure compressor housings and turbine skids.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003ePart Number Configuration Breakdown\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003e330903\u003c\/b\u003e — \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003eBently Nevada 3300 NSv\u003c\/span\u003e\u003c\/b\u003e Probe, M8x1 Thread, Without Armor\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003e-00-\u003c\/b\u003e — Unthreaded Length Option: 00 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e-05-\u003c\/b\u003e — Overall Case Length Option: 50 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e-70-\u003c\/b\u003e — Total Length Option: 7.0 meters (23.0 feet)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e-01-\u003c\/b\u003e — Connector and Cable Type Option: Miniature coaxial ClickLoc connector with standard cable and connector protector\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e-05-\u003c\/b\u003e — Agency Approval Option: Multiple International Approvals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter Category\u003c\/th\u003e\n\u003cth\u003eTechnical Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eBrand \u0026amp; Model\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003eBently Nevada 330903-00-05-70-01-05\u003c\/span\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eProduct Series\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003eBently Nevada 3300 NSv\u003c\/span\u003e\u003c\/b\u003e Proximity Transducer System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eLinear Measurement Range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 mm (60 mils), starting at approx 0.25 mm (10 mils) to 1.75 mm (70 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eIncremental Scale Factor (ISF)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) +12.5%\/-20% across linear range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eLinearity (DSL)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eDeviation from best fit straight line less than ±0.06 mm (±2.3 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eRecommended Gap Setting\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0 mm (40 mils), approx -1 to -13 Vdc output window\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eFrequency Response\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz (+0, -3 dB typical with up to 305 m field wiring)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eTarget Size Requirement\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eMinimum diameter 8.9 mm (0.35 in); Recommended minimum 13 mm (0.5 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eElectrical Resistance \u0026amp; Cap\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eProbe DC Resistance 5.9 ± 0.9 Ω; Extension Cable Cap 69.9 pF\/m typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eMaterials \u0026amp; Temperature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ePPS tip, 304 SST case, FEP cable; Operating Temp -52 °C to +177 °C (-62 °F to +351 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cb\u003eDiagnostic Capabilities\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eVibration \u0026amp; Gap Voltage Supervision\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous DC gap voltage verification confirms physical probe-to-target distance.\u003c\/li\u003e\n\u003cli\u003eAC voltage modulation tracking provides real-time peak-to-peak shaft vibration measurements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eTransducer Loop Health Check\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eSignal loss or short circuits force proximitor output to out-of-range limit states for instant alarm detection.\u003c\/li\u003e\n\u003cli\u003eIntegrates miniature coaxial ClickLoc connectors with molded protectors to eliminate signal attenuation from moisture ingress.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eSuitable Equipment \u0026amp; Application Scenarios\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eCentrifugal \u0026amp; Axial Process Compressors\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eMonitors shaft radial vibration and axial position inside narrow bearing housings.\u003c\/li\u003e\n\u003cli\u003ePPS probe tip material offers superior resistance against aggressive chemical process gases compared to older probe designs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSmall Steam Turbines \u0026amp; Auxiliary Pumps\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal for installation where side-view clearance is restricted or target shaft diameter is below 13 mm.\u003c\/li\u003e\n\u003cli\u003ePrevents false vibration readings caused by adjacent metal side walls due to tight side-view characteristics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eHigh-Speed Industrial Gearboxes\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eTracks radial shaft motion and gear mesh frequencies across broad operating temperature ranges (-52 °C to +177 °C).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eSystem Compatibility\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eInterchangeability Assurance\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eFully interchangeable electrically and mechanically with legacy Bently Nevada 3300 RAM proximity probes.\u003c\/li\u003e\n\u003cli\u003eDirect replacement for 3000-series 190 probes with superior target gapping performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eProximitor \u0026amp; Wiring Integration\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eConnects to 3300 XL NSv Proximitor Sensors using standard 75 Ω coaxial extensions.\u003c\/li\u003e\n\u003cli\u003eSupports field wiring distances up to 305 meters (1,000 feet) using 3-conductor shielded triad cable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eInstallation \u0026amp; Torque Guide\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eMechanical Mounting Procedures\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eThread probe case into M8x1 tapped hole with maximum engagement length of 12 mm.\u003c\/li\u003e\n\u003cli\u003eHand-tighten probe body, maintaining recommended installation torque of 5.1 N•m (45 in•lb) up to max 7.3 N•m (65 in•lb).\u003c\/li\u003e\n\u003cli\u003eMaintain minimum cable bend radius of 25.4 mm (1.0 in) during cable routing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eGapping \u0026amp; Electrical Zeroing\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eSet physical mechanical gap to 1.0 mm (40 mils) off shaft target.\u003c\/li\u003e\n\u003cli\u003eVerify DC bias voltage reading at Proximitor output aligns with system calibration limits (-9 to -11 Vdc target center).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eCommissioning \u0026amp; Maintenance\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eField Testing Routine\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eCheck center-to-outer conductor probe resistance prior to installation (nominal 5.9 ± 0.9 ohms for 7m system).\u003c\/li\u003e\n\u003cli\u003eEnsure ClickLoc coaxial connectors are fully seated and connector protectors are snapped tight.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eRoutine Inspection\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eRegularly check cable jacket integrity for chemical attack or mechanical abrasion.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eCertifications \u0026amp; Standards\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eCompliance Standards\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eAgency Approvals\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eOption 05: Multiple international approvals for hazardous locations (ATEX, IECEx, CSA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eEnvironmental Endurance\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eViton O-ring differential pressure sealing; IP67 rated connector protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cb\u003ePackage \u0026amp; Delivery Information\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eShipping Logistics\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eOrders dispatch within 24 to 48 hours following order confirmation.\u003c\/li\u003e\n\u003cli\u003eExpress global shipping provided via FedEx, UPS, and DHL air transport.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eWarranty \u0026amp; Condition\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003e100% Brand New and Original item supplied in factory-sealed packing.\u003c\/li\u003e\n\u003cli\u003eIncludes comprehensive 12-Month full factory warranty coverage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eGlobal PLC Spare HUB's Insight\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eOur vibration monitoring specialists frequently specify the \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003eBently Nevada 330903-00-05-70-01-05\u003c\/span\u003e\u003c\/b\u003e for machinery retrofits with tight physical clearances. During a recent boiler feed pump upgrade, engineers could not install standard 8 mm probes due to narrow internal counterbores. The narrow side-view profile of the \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003e3300 NSv\u003c\/span\u003e\u003c\/b\u003e probe allowed installation without side-wall interference affecting the scale factor. Utilizing the 7.0-meter integrated probe length simplified cable management by routing the coaxial connection directly outside the hot bearing housing without requiring internal extension jumpers.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSelection Guide\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eProbe Selection: Standard 3300 XL vs. 3300 NSv\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eSelect standard 8 mm 3300 XL probes for unobstructed shaft areas with target diameters above 30 mm.\u003c\/li\u003e\n\u003cli\u003eSelect the \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003e330903-00-05-70-01-05\u003c\/span\u003e\u003c\/b\u003e NSv probe for targets smaller than 13 mm or when mounting in tight counterbores.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCable Length Matching\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eMatch probe length and extension cable total length exactly to the Proximitor calibration requirement (e.g., 7m probe system paired with 7m calibrated Proximitor).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eFrequently Asked Questions (FAQ)\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eQ: What is the main structural advantage of the 3300 NSv probe over older 3000-series 190 probes?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: The \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003e330903-00-05-70-01-05\u003c\/span\u003e\u003c\/b\u003e offers significantly reduced side-view sensitivity, preventing measurement errors caused by surrounding metal walls in small counterbores.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ: Can I connect this 7.0-meter probe directly to a Proximitor sensor without an extension cable?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. Because this specific part number has an integrated total length of 7.0 meters (-70 option), it connects directly to a 7.0-meter system Proximitor without requiring an intermediate extension cable.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ: How does target shaft diameter affect the probe scale factor during measurement?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Target diameters smaller than 13 mm (0.5 in) alter the Incremental Scale Factor (ISF); reducing the operating gap setting slightly helps compensate for scale factor drift on small shafts.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ: What electrical resistance should I measure across the probe connectors during a field health check?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: For a healthy 7.0-meter \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003e330903-00-05-70-01-05\u003c\/span\u003e\u003c\/b\u003e probe, the DC resistance between the center conductor and outer shield should measure 5.9 ± 0.9 ohms.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ: What is the correct tightening torque for installing the M8x1 probe thread into a bearing housing?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Recommended mounting torque is 5.1 N•m (45 in•lb), and you should never exceed the maximum rated torque of 7.3 N•m (65 in•lb) to prevent thread deformation.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330901-330910_432da41b-a3bf-4c98-a960-7a1ed65c995c.png?v=1782895913\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013977923766,"sku":"330903-00-05-70-01-05","price":179.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/BentlyNevada330903_8.jpg?v=1787650308","url":"https:\/\/www.plcsparehub.com\/products\/330903-00-05-70-01-05-bently-nevada-3300-nsv-sensor-probe-quick-quote","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}