{"product_id":"330903-00-02-10-12-05-bently-nevada-3300-nsv-eddy-current-sensor","title":"330903-00-02-10-12-05 Bently Nevada 3300 NSv Eddy Current Sensor","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eBently Nevada 330903-00-02-10-12-05\u003c\/strong\u003e\u003c\/span\u003e is a high-precision eddy current proximity probe from the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e3300 NSv\u003c\/strong\u003e\u003c\/span\u003e series. Engineers deploy this transducer system to monitor radial vibration and axial thrust position on rotating machinery. Its compact geometry targets confined installation spaces with small shafts and tight side-view clearances. The probe tip features chemical-resistant polyphenylene sulfide (PPS) housing paired with a durable AISI 304 stainless steel case. Furthermore, the integrated FluidLoc cable prevents oil and process liquids from leaking out through the cable interior. This specific \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e330903-00-02-10-12-05\u003c\/strong\u003e\u003c\/span\u003e configuration includes an M8x1 threaded body, 20 mm overall case length, and a 1.0-meter total length.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" width=\"100%\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth align=\"left\"\u003eParameter Category\u003c\/th\u003e\n\u003cth align=\"left\"\u003eSpecification\u003c\/th\u003e\n\u003cth align=\"left\"\u003eTechnical Value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIdentity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManufacturer \/ Brand\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eBently Nevada\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIdentity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e330903-00-02-10-12-05\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIdentity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e3300 NSv\u003c\/strong\u003e\u003c\/span\u003e Proximity Probe System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLinear Measurement Range\u003c\/td\u003e\n\u003ctd\u003e1.5 mm (60 mils), starting at 0.25 mm (10 mils) to 1.75 mm (70 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz (+0, -3 dB typical with up to 305 m field wiring)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSensitivity (Incremental Scale Factor)\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) +12.5% \/ -20% (including interchangeability error)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLinearity (DSL)\u003c\/td\u003e\n\u003ctd\u003eLess than ±0.06 mm (±2.3 mils) deviation from best-fit straight line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003eContinuous analog output determined by downstream monitor input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProbe DC Resistance (RPROBE)\u003c\/td\u003e\n\u003ctd\u003e4.2 Ω ± 0.5 Ω (center conductor to outer conductor for 1.0 m probe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExtension Cable DC Resistance\u003c\/td\u003e\n\u003ctd\u003eCenter: 0.220 Ω\/m (0.067 Ω\/ft); Shield: 0.066 Ω\/m (0.020 Ω\/ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExtension Cable Capacitance\u003c\/td\u003e\n\u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCase Thread \u0026amp; Engagement\u003c\/td\u003e\n\u003ctd\u003eM8x1 thread; 12 mm maximum thread engagement length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCase \u0026amp; Unthreaded Length\u003c\/td\u003e\n\u003ctd\u003e0 mm unthreaded length; 20 mm overall case length; no armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTotal Cable Length \u0026amp; Type\u003c\/td\u003e\n\u003ctd\u003e1.0 meter (39 in); 75 Ω coaxial FEP insulated FluidLoc cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperating \u0026amp; Storage Temperature\u003c\/td\u003e\n\u003ctd\u003e-52°C to +177°C (-62°F to +351°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEnvironmental Resistance\u003c\/td\u003e\n\u003ctd\u003eEnhanced chemical resistance; Viton O-ring differential pressure seal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInterference Immunity\u003c\/td\u003e\n\u003ctd\u003e75 Ω coaxial shielding; supports three-conductor shielded triad field wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTarget Sizing:\u003c\/strong\u003e Use a flat target with a minimum 8.9 mm diameter. Select a 13 mm diameter target for optimal scale factor stability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGap Setting:\u003c\/strong\u003e Set the initial mechanical gap to \u003cstrong\u003e1.0 mm (40 mils)\u003c\/strong\u003e from the target surface, corresponding to approximately -7 Vdc.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCase Torque:\u003c\/strong\u003e Tighten the M8x1 probe case to a recommended torque of \u003cstrong\u003e5.1 N•m (45 in•lb)\u003c\/strong\u003e. Do not exceed 7.3 N•m (65 in•lb).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Torque:\u003c\/strong\u003e Tighten the miniature ClickLoc connector finger-tight. Never exceed a maximum torque of \u003cstrong\u003e0.56 N•m (5 in•lb)\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Maintain a minimum bend radius of \u003cstrong\u003e25.4 mm (1.0 in)\u003c\/strong\u003e to prevent coaxial impedance shifts or conductor damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring:\u003c\/strong\u003e Connect the Proximitor sensor to the monitor using 0.2 to 1.5 mm² (16 to 24 AWG) three-conductor shielded triad cable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCommissioning \u0026amp; Maintenance Convenience\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClickLoc Locking Mechanism:\u003c\/strong\u003e The miniature coaxial ClickLoc connector audibly clicks into place, preventing accidental vibration-induced disconnections during turbine operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFluidLoc Leakage Barrier:\u003c\/strong\u003e Integrated FluidLoc cable construction blocks internal oil wicking, protecting downstream junction boxes and monitors from fluid contamination.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterchangeable Calibration:\u003c\/strong\u003e Standardized 7.87 V\/mm scale factor allows direct field replacement without recalibrating the entire transducer loop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Verification:\u003c\/strong\u003e Technicians easily verify probe integrity by measuring loop resistance (4.2 Ω ± 0.5 Ω) at the Proximitor terminal.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackward Interchangeability:\u003c\/strong\u003e The \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e3300 NSv\u003c\/strong\u003e\u003c\/span\u003e probe and extension cable are mechanically and electrically interchangeable with legacy \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e3300 RAM\u003c\/strong\u003e\u003c\/span\u003e systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpgraded Side-View Performance:\u003c\/strong\u003e This probe provides superior side-view clearance compared to 3000-series 190 probes at identical target gap distances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Compressor Suitability:\u003c\/strong\u003e Enhanced chemical resistance enables reliable deployment in harsh centrifugal and process compressor environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransducer Matching:\u003c\/strong\u003e Pair this 1.0-meter probe with a matching \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e3300 XL NSv\u003c\/strong\u003e\u003c\/span\u003e extension cable and Proximitor sensor to achieve exact system electrical length.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCertifications \u0026amp; Approvals\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAgency Approval Option (-05):\u003c\/strong\u003e Factory-certified with Multiple Approvals for hazardous industrial locations (including CSA, ATEX, and IECEx standards).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Sealing Note:\u003c\/strong\u003e The internal Viton O-ring seals differential pressure between the probe tip and case. Factory shipment does not include individual pressure testing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eBently Nevada 330903-00-02-10-12-05\u003c\/strong\u003e\u003c\/span\u003e Proximity Probe (New \u0026amp; Original in Factory Packing)\u003c\/li\u003e\n\u003cli\u003e1 x Factory Calibration \u0026amp; Compliance Documentation\u003c\/li\u003e\n\u003cli\u003e12-Month Standard Warranty Coverage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How do I select the correct thread and case length for my machine?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: Choose the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e330903\u003c\/strong\u003e\u003c\/span\u003e model when your mounting bracket requires an M8x1 metric thread without stainless steel armor. Ensure your bracket thickness accommodates the 20 mm overall case length and 12 mm maximum thread engagement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can I replace a 3300 RAM probe with this 3300 NSv probe without changing my Proximitor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: Yes, the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e3300 NSv\u003c\/strong\u003e\u003c\/span\u003e probe is fully compatible with \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e3300 RAM\u003c\/strong\u003e\u003c\/span\u003e extension cables and Proximitor sensors. However, always ensure the total electrical length of the probe plus extension cable matches the Proximitor specification.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What happens if I mount this probe near a shaft smaller than 13 mm in diameter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: Shafts smaller than 13 mm reduce the Incremental Scale Factor due to target curvature. You can minimize this scale factor shift by setting a slightly tighter initial gap closer to 0.75 mm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Why does the output voltage drift at high frequencies over long cable runs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA4: Field wiring approaching the 305-meter maximum limit introduces capacitive loading. This capacitance causes high-frequency signal rolloff above 10 kHz. Use low-capacitance shielded triad cable to preserve signal fidelity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: When should I choose the FluidLoc cable option (-12) over standard cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA5: Always select the FluidLoc option when installing probes inside oil-lubricated bearing housings or pressurized gearboxes. It stops pressurized oil from migrating through the braided shield into external electronics.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330901-330910_432da41b-a3bf-4c98-a960-7a1ed65c995c.png?v=1782895913\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013863825590,"sku":"330903-00-02-10-12-05","price":179.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/BentlyNevada330903_7.jpg?v=1788762226","url":"https:\/\/www.plcsparehub.com\/products\/330903-00-02-10-12-05-bently-nevada-3300-nsv-eddy-current-sensor","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}