{"product_id":"330902-00-12-10-02-00-bently-nevada-3300-nsv-proximity-probe","title":"330902-00-12-10-02-00 Bently Nevada 3300 NSv Proximity Probe","description":"\u003ch3\u003e\u003cstrong\u003eTransducer Architecture \u0026amp; Narrow-Sideview Design\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003e330902-00-12-10-02-00\u003c\/strong\u003e\u003c\/span\u003e is a precision-engineered eddy current proximity probe belonging to the Bently Nevada \u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003e3300 NSv\u003c\/strong\u003e\u003c\/span\u003e (Narrow Sideview) transducer system. Manufactured in the U.S.A., this armored 1\/4-28 UNF probe targets centrifugal air compressors, refrigeration compressors, and compact turbomachinery where tight counterbore clearances and reduced target areas restrict standard 8 mm probes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePart Number Suffix \u0026amp; Configuration Hierarchy\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003e330902-00-12-10-02-00\u003c\/strong\u003e\u003c\/span\u003e (Complete Assembly Code)\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e330902\u003c\/strong\u003e — Base Probe Model: \u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003e3300 NSv\u003c\/strong\u003e\u003c\/span\u003e Probe, 1\/4-28 UNF Thread, with Flexible Stainless Steel Armor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-00\u003c\/strong\u003e — Unthreaded Length Option: 0.0 in (Fully threaded case up to the tip transition)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-12\u003c\/strong\u003e — Overall Case Length Option: 1.2 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-10\u003c\/strong\u003e — Total Cable Length Option: 1.0 meter (39 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-02\u003c\/strong\u003e — Connector \u0026amp; Cable Option: Miniature coaxial ClickLoc connector with standard FEP cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-00\u003c\/strong\u003e — Agency Approval Option: Not required (Standard industrial area deployment)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMechanical, Electrical \u0026amp; Environmental Data\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eEngineering Domain\u003c\/th\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eTechnical Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e\u003cstrong\u003eIdentification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManufacturer \u0026amp; Origin\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Made in U.S.A.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \u0026amp; Series\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003e330902-00-12-10-02-00\u003c\/strong\u003e\u003c\/span\u003e | \u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003e3300 NSv\u003c\/strong\u003e\u003c\/span\u003e Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMass \/ Weight\u003c\/td\u003e\n\u003ctd\u003eApprox. 14 to 150 g (0.5 to 5.3 oz), configuration dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003e\u003cstrong\u003ePhysical \u0026amp; Materials\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCase \u0026amp; Tip Materials\u003c\/td\u003e\n\u003ctd\u003eAISI 304 Stainless Steel (SST) case; Polyphenylene Sulfide (PPS) tip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Seal\u003c\/td\u003e\n\u003ctd\u003eViton O-ring differential pressure seal (untested prior to shipment)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Engagement Limit\u003c\/td\u003e\n\u003ctd\u003e0.375 in maximum thread engagement for 1\/4-28 UNF case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Torque\u003c\/td\u003e\n\u003ctd\u003e5.1 N·m (45 in·lb) recommended; 7.3 N·m (65 in·lb) maximum rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cstrong\u003eElectrical \u0026amp; Cabling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCoaxial Cable Spec\u003c\/td\u003e\n\u003ctd\u003e75 Ω coaxial, Fluoroethylene Propylene (FEP) insulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe DC Resistance\u003c\/td\u003e\n\u003ctd\u003e4.2 ± 0.5 Ω (center-to-outer conductor for 1.0 m length)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cstrong\u003eThermal Limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperating \u0026amp; Storage Temp\u003c\/td\u003e\n\u003ctd\u003e-52°C to +177°C (-62°F to +351°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow-Temp Seal Advisory\u003c\/td\u003e\n\u003ctd\u003eSustained exposure below -34°C (-30°F) risks premature Viton seal degradation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eModel Selection Comparison \u0026amp; Engineering Guidance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eCompare the \u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003e330902-00-12-10-02-00\u003c\/strong\u003e\u003c\/span\u003e against the related armored 1\/4-28 UNF variant \u003ca href=\"https:\/\/www.plcsparehub.com\/products\/330902-00-95-05-01-00-bently-nevada-3300-nsv-proximity-probe\"\u003e\u003cstrong\u003e330902-00-95-05-01-00\u003c\/strong\u003e\u003c\/a\u003e to select the exact mechanical and electrical fit for your machine casing:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSelection Attribute\u003c\/th\u003e\n\u003cth\u003e\n\u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003e330902-00-12-10-02-00\u003c\/strong\u003e\u003c\/span\u003e (Current Model)\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.plcsparehub.com\/products\/330902-00-95-05-01-00-bently-nevada-3300-nsv-proximity-probe\"\u003e\u003cstrong\u003e330902-00-95-05-01-00\u003c\/strong\u003e\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Architecture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330902 (1\/4-28 UNF, Armored)\u003c\/td\u003e\n\u003ctd\u003e330902 (1\/4-28 UNF, Armored)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 in (Option 00)\u003c\/td\u003e\n\u003ctd\u003e0.0 in (Option 00)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Case Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e1.2 in\u003c\/strong\u003e (Option 12)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e9.5 in\u003c\/strong\u003e (Option 95)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e1.0 meter \/ 39 in\u003c\/strong\u003e (Option 10)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e0.5 meter \/ 20 in\u003c\/strong\u003e (Option 05)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector \u0026amp; Cable Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eClickLoc connector, standard cable\u003c\/strong\u003e (Option 02)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eClickLoc connector with protector, standard cable\u003c\/strong\u003e (Option 01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAgency Approval\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot required (Option 00)\u003c\/td\u003e\n\u003ctd\u003eNot required (Option 00)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCasing Wall Depth Recommendation:\u003c\/strong\u003e Choose the \u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003e330902-00-12-10-02-00\u003c\/strong\u003e\u003c\/span\u003e (1.2 in case) for thin-walled bearing housings or shallow internal brackets where rear clearance behind the mounting tap is tight. Select \u003ca href=\"https:\/\/www.plcsparehub.com\/products\/330902-00-95-05-01-00-bently-nevada-3300-nsv-proximity-probe\"\u003e\u003cstrong\u003e330902-00-95-05-01-00\u003c\/strong\u003e\u003c\/a\u003e (9.5 in case) when reaching deep through thick compressor casings or external adapter blocks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing \u0026amp; Connector Protection:\u003c\/strong\u003e If the miniature ClickLoc junction sits inside an oil-mist bearing cavity or exposed splash zone, the \u003ca href=\"https:\/\/www.plcsparehub.com\/products\/330902-00-95-05-01-00-bently-nevada-3300-nsv-proximity-probe\"\u003e\u003cstrong\u003e330902-00-95-05-01-00\u003c\/strong\u003e\u003c\/a\u003e provides an integrated connector protector (Option 01) and a shorter 0.5 m pigtail, whereas the \u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003e330902-00-12-10-02-00\u003c\/strong\u003e\u003c\/span\u003e offers a 1.0 m reach for routing directly to an external junction box.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Electrical Tuning:\u003c\/strong\u003e Never mix 0.5 m and 1.0 m probes with mismatched extension cables; always match your extension cable length so total system electrical length equals exactly 5.0 m or 7.0 m to match the \u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003e3300 NSv\u003c\/strong\u003e\u003c\/span\u003e Proximitor sensor calibration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eField Installation \u0026amp; Reliability Checklist\u003c\/strong\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eLimit thread engagement on the 1\/4-28 UNF case to 0.375 in maximum to prevent mechanical distortion of the internal coil assembly.\u003c\/li\u003e\n\u003cli\u003eTorque the locknut strictly to 5.1 N·m (45 in·lb) during installation; never exceed the 7.3 N·m (65 in·lb) absolute limit.\u003c\/li\u003e\n\u003cli\u003eVerify DC loop resistance across the ClickLoc connector (4.2 ± 0.5 Ω) using a calibrated multimeter before closing the machine housing.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003e\u003cstrong\u003eTurbomachinery Engineering FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why is the \u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003e3300 NSv\u003c\/strong\u003e\u003c\/span\u003e probe preferred over standard 8 mm probes in high-speed centrifugal compressors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Its compact PPS tip and 1\/4-28 UNF body require significantly smaller target areas and tighter side clearances, eliminating false eddy current field loading from adjacent counterbore walls or rotor shoulders.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What causes premature seal leakage when operating the \u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003e330902-00-12-10-02-00\u003c\/strong\u003e\u003c\/span\u003e in cryogenic or cold-start applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Although the probe body survives down to -52°C, sustained operation below -34°C (-30°F) hardens the internal Viton O-ring beyond its elastic glass-transition point, compromising differential pressure sealing between the tip and case.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can technicians cut or splice the 1.0-meter FEP coaxial cable if excess slack remains inside the junction box?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Never cut or alter the coaxial cable length. The 75 Ω cable acts as a tuned capacitive element within the RF tank circuit; shortening it shifts the oscillator frequency and invalidates the linear scale factor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does exceeding the 0.375-inch maximum thread engagement limit affect probe performance?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Over-threading compresses the thin-walled AISI 304 stainless steel sleeve near the sensor head, potentially cracking the internal ceramic\/PPS coil encapsulation or shifting thermal drift characteristics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What field checks confirm whether an erratic gap voltage stems from the probe or the extension cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Disconnect the miniature ClickLoc connector and measure center-to-shield DC resistance directly on the probe; readings outside 4.2 ± 0.5 Ω or continuity to the stainless steel armor indicate internal conductor fatigue or moisture ingress.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330901-330910_432da41b-a3bf-4c98-a960-7a1ed65c995c.png?v=1782895913\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013974384822,"sku":"330902-00-12-10-02-00","price":160.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/BentlyNevada330902_2_dc567c42-b996-4344-b030-88d70a72e24f.jpg?v=1789107968","url":"https:\/\/www.plcsparehub.com\/products\/330902-00-12-10-02-00-bently-nevada-3300-nsv-proximity-probe","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}