{"product_id":"330901-22-90-10-11-05-3300-series-bently-nevada-nsv-proximity-probe-system","title":"330901-22-90-10-11-05 3300 Series Bently Nevada NSv Proximity Probe System","description":"\u003ch3\u003eEngineering Summary\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cstrong\u003e330901-22-90-10-11-05\u003c\/strong\u003e\u003c\/strong\u003e is an unarmored 3300 NSv proximity transducer engineered by \u003cstrong\u003e\u003cstrong\u003eBently Nevada\u003c\/strong\u003e\u003c\/strong\u003e for precise machinery monitoring. Identified within the \u003cstrong\u003e\u003cstrong\u003e330901\u003c\/strong\u003e\u003c\/strong\u003e product family and \u003cstrong\u003e\u003cstrong\u003e3300 NSv\u003c\/strong\u003e\u003c\/strong\u003e series, this sensor features a 1\/4-28 UNF thread configuration with a 2.2-inch unthreaded length and 9.0-inch overall case length. Global PLC Spare HUB's Insight highlights that FluidLoc cable technology prevents oil and gas migration through the cable core, making it vital for harsh petrochemical environments.\u003c\/p\u003e\n\u003ch3\u003eConfiguration Tree Structure\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Model: 330901\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eUnthreaded Length Option (22): 2.2 in extended bare case\u003c\/li\u003e\n\u003cli\u003eOverall Case Length Option (90): 9.0 in total mechanical housing length\u003c\/li\u003e\n\u003cli\u003eTotal Length Option (10): 1.0 metre (39 in) system electrical length\u003c\/li\u003e\n\u003cli\u003eConnector \u0026amp; Cable Option (11): Miniature coaxial ClickLoc connector with protector and FluidLoc cable\u003c\/li\u003e\n\u003cli\u003eAgency Approval Option (05): Multiple hazardous area certifications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Parameter Matrix\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePerformance Metric\u003c\/th\u003e\n\u003cth\u003eEngineering Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand and Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cstrong\u003eBently Nevada\u003c\/strong\u003e\u003c\/strong\u003e \u003cstrong\u003e\u003cstrong\u003e330901-22-90-10-11-05\u003c\/strong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.2 $\\pm$ 0.5 ohms (center to outer conductor for 1.0m length)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Endurance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperating and storage limits from -52°C to +177°C (-62°F to +351°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRecommended 5.1 N•m (45 in•lb), maximum 7.3 N•m (65 in•lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThread Limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaximum thread engagement length of 0.375 in for 1\/4-28 cases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial Composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAISI304 stainless steel case with Polyphenylene sulfide (PPS) tip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDiagnostic and Signal Integrity Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFluidLoc cable design blocks capillary fluid wicking into monitoring racks.\u003c\/li\u003e\n\u003cli\u003eStable linear DC response tracking micro-displacement on restricted target surfaces.\u003c\/li\u003e\n\u003cli\u003eClickLoc connector locking mechanism ensures secure electrical continuity under high frequency shock.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and Mechanical Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eObserve the strict 0.375-inch thread engagement limit to prevent internal stress.\u003c\/li\u003e\n\u003cli\u003eUse calibrated torque tools to set the 5.1 N•m fastening threshold on the mounting bracket.\u003c\/li\u003e\n\u003cli\u003eProtect the Viton O-ring seal from pre-mounting exposure to temperatures below -34°C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTarget Applications and Equipment Suitability\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCentrifugal compressor radial vibration and axial thrust monitoring.\u003c\/li\u003e\n\u003cli\u003eSpecialized high-speed steam turbine auxiliary gearboxes.\u003c\/li\u003e\n\u003cli\u003eIndustrial environments requiring fluid-blocking cable integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFulfillment and Guarantee Terms\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFully backed by a standard 12-month commercial warranty.\u003c\/li\u003e\n\u003cli\u003eFast 24-48 hour order processing and global delivery via \u003cstrong\u003eFedEx\u003c\/strong\u003e, \u003cstrong\u003eUPS\u003c\/strong\u003e, and \u003cstrong\u003eDHL\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSelection and Technical Cross-Reference\u003c\/h3\u003e\n\u003cp\u003eWhen engineering custom probe bracket depths, comparing case lengths and cable termination styles ensures optimal fit. For an alternative configuration featuring shorter unthreaded dimensions and standard cabling within the same hardware architecture, reference the \u003ca href=\"https:\/\/www.plcsparehub.com\/products\/330901-14-43-10-02-05-bently-nevada-3300-nsv-proximity-probe\"\u003e330901-14-43-10-02-05\u003c\/a\u003e Bently Nevada 3300 NSv proximity probe model.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What specific advantage does FluidLoc cable technology provide in this model?\u003c\/strong\u003e\u003cbr\u003eA: FluidLoc construction incorporates specialized blocking agents inside the FEP cable core, stopping oil or gas from leaking through the cable assembly into control cabinets.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why does the 330901-22-90-10-11-05 utilize an extended 2.2-inch unthreaded section?\u003c\/strong\u003e\u003cbr\u003eA: The 2.2-inch unthreaded length allows technicians to pass the probe through thick machine mounting walls or external thermal insulation sleeves before engaging the threads.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does cable length adjustment affect the DC resistance specification?\u003c\/strong\u003e\u003cbr\u003eA: Total electrical length alters loop resistance; this 1.0-metre variant is factory-calibrated to maintain a center-to-outer conductor resistance of 4.2 $\\pm$ 0.5 ohms.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What installation error most commonly damages the probe housing threads?\u003c\/strong\u003e\u003cbr\u003eA: Exceeding the maximum 0.375-inch thread engagement limit or over-tightening past 7.3 N•m can strip the 1\/4-28 UNF threads or distort the stainless steel casing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How should maintenance teams store spare unarmored NSv probes on-site?\u003c\/strong\u003e\u003cbr\u003eA: Store probes in a temperature-controlled environment above -34°C to preserve the elasticity and sealing performance of the Viton O-ring pressure barrier.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330901-330910_4b200e96-8853-4e56-b3a8-5e16f60388de.png?v=1782722898\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013961310390,"sku":"330901-22-90-10-11-05","price":150.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/BentlyNevada330901_7_9eb1c8a6-d737-47e2-9930-ccd77507ba48.jpg?v=1789357878","url":"https:\/\/www.plcsparehub.com\/products\/330901-22-90-10-11-05-3300-series-bently-nevada-nsv-proximity-probe-system","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}