{"product_id":"330801-16-10-110-06-02-bently-nevada-proxpac-proximity-transducer","title":"330801-16-10-110-06-02 Bently Nevada PROXPAC Proximity Transducer","description":"\u003ch3\u003e\u003cb\u003eBently Nevada 330801-16-10-110-06-02 PROXPAC Proximity Transducer Architecture Overview\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eInstrumentation engineers implement the \u003cb\u003e\u003cb\u003e330801-16-10-110-06-02\u003c\/b\u003e\u003c\/b\u003e self-contained transducer assembly to monitor mechanical displacement in severe industrial environments. This self-contained unit integrates the proximitor sensor directly into the housing cover, eliminating external extension cabling. \u003cb\u003e\u003cb\u003eBently Nevada\u003c\/b\u003e\u003c\/b\u003e builds this \u003cb\u003e\u003cb\u003ePROXPAC XL Series\u003c\/b\u003e\u003c\/b\u003e assembly utilizing ultraviolet-resistant polyphenylene sulfide (PPS) thermoplastic molded with glass and conductive fibers to dissipate electrostatic charges safely while meeting IP66 and Type 4X ratings.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cb\u003eConfiguration Breakdown and Suffix Hierarchy\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse: collapse; width: 100%;\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003e\u003cb\u003eParameter Designation\u003c\/b\u003e\u003c\/th\u003e\n      \u003cth\u003e\u003cb\u003eConfigured Suffix Option\u003c\/b\u003e\u003c\/th\u003e\n      \u003cth\u003e\u003cb\u003eEngineering Specification\u003c\/b\u003e\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eManufacturer Brand\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cb\u003e\u003cb\u003eBently Nevada\u003c\/b\u003e\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003eOriginal Equipment Manufacturer\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eBase Product Family\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cb\u003e\u003cb\u003e330801\u003c\/b\u003e\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC Proximity Transducer Assembly Platform\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eComplete Part Number\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cb\u003e\u003cb\u003e330801-16-10-110-06-02\u003c\/b\u003e\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003eFully assembled transducer unit including probe, adapter, penetration, and fittings\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eProbe and Approvals Option\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cb\u003e16\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm proximity probe configuration\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eStandoff Adapter Option\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cb\u003e10\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003e100 mm standoff distance profile\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eProbe Penetration Option\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cb\u003e110\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003e110 mm total probe penetration depth\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eFittings Kit Option\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cb\u003e06\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003eOne 3\/4-14 NPT fitting, one 3\/4-14 to 1\/2-14 NPT SST reducer, and two plugs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eMounting Thread Option\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cb\u003e02\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003e3\/4-14 NPT thread required for standoff adapter mounting\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cb\u003eElectrical and Performance Parameters\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cb\u003eLinear Measurement Range:\u003c\/b\u003e 2 mm (80 mils) spanning from 0.25 to 2.3 mm (10 to 90 mils) (-1 Vdc to -17 Vdc)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eIncremental Scale Factor (ISF):\u003c\/b\u003e 7.87 V\/mm (200 mV\/mil) nominal output including interchangeability error\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eOutput Impedance Resistance:\u003c\/b\u003e 50 Ω matching resistance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003ePower Supply Requirements:\u003c\/b\u003e -17.5 Vdc to -26 Vdc without barriers at 12 mA maximum current draw\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eDeviation from Best Fit Straight Line (DSL):\u003c\/b\u003e Less than ±0.025 mm (±1 mil) for standard 1-meter configurations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eFrequency Response Range:\u003c\/b\u003e 0 to 10 kHz (+0, -3 dB) with up to 305 meters (1000 feet) of field wiring\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eShipping Gross Weight:\u003c\/b\u003e 2.5 Kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eField Wiring and Installation Guidelines\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cb\u003eConductor Requirements:\u003c\/b\u003e Utilize 0.2 to 1.5 mm2 (16 to 24 AWG) three-conductor shielded triax cable with tinned field wiring\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eDistance Limitations:\u003c\/b\u003e Maintain a maximum of 305 meters (1,000 feet) between the assembly and the monitor rack\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eMinimum Target Size:\u003c\/b\u003e Requires a flat target surface of at least 15.2 mm (0.6 in) in diameter\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eMinimum Shaft Diameter:\u003c\/b\u003e Suitable for rotating equipment shafts of at least 50.8 mm (2.0 in) diameter\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eLogistics and Warranty Terms\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eWe supply 100% brand new, factory-original units housed in secure packaging. Orders dispatch within 24 to 48 hours via premium global courier networks including FedEx, UPS, and DHL. Every purchase includes a comprehensive 12-month factory warranty.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cb\u003eTarget Machinery, Application Scenarios, and Diagnostics\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003ePlant operators deploy the \u003cb\u003e\u003cb\u003e330801-16-10-110-06-02\u003c\/b\u003e\u003c\/b\u003e transducer assembly on severe-duty centrifugal compressors, heavy industrial blowers, and large pumps operating in corrosive or weather-exposed environments. The self-contained IP66-rated housing protects internal electronics while delivering precise radial vibration and shaft position metrics. Diagnostic systems analyze these high-frequency voltage shifts to identify oil whirl, fluid instability, and rotor eccentricity before mechanical failure occurs.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cb\u003eGlobal PLC Spare HUB Insight \u0026amp; Field Engineering Experience\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eInstrumentation specialists frequently encounter signal offset errors in harsh outdoor installations when moisture breaches improperly sealed conduit connections. For instance, a chemical processing facility resolved erratic DC gap voltage readings on an outdoor boiler feed pump by replacing standard fittings with the correct NPT reducer kit and ensuring proper shield grounding at the instrumentation cabinet. Engineers recommend verifying the 1.27 mm (50 mils) recommended gap setting during initial mechanical alignment to ensure full linear operating range.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cb\u003eFrequently Asked Questions\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eQ: What structural advantage does the Polyphenylene Sulfide housing provide over legacy metal enclosures?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: The molded thermoplastic body incorporates glass and conductive fibers that strengthen the structure while effectively dissipating electrostatic charges in hazardous areas.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eQ: Why does this design eliminate the need for an external extension cable?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: The integral proximitor sensor is housed directly inside the transducer cover, allowing field wiring to connect straight from the monitor to the assembly head.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eQ: What operational consequence occurs if the supply voltage becomes more positive than -23.5 Vdc?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Operating outside the specified negative voltage window restricts the linear measurement range and distorts vibration signal output.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eQ: How do technicians verify correct probe positioning during installation?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Technicians set the target gap to the recommended 1.27 mm (50 mils) while measuring voltage to align with the nominal -1 Vdc starting point.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eQ: What criteria should buyers evaluate when ordering replacement transducer kits?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Buyers must match the complete suffix string—such as the \u003cb\u003e\u003cb\u003e16-10-110-06-02\u003c\/b\u003e\u003c\/b\u003e configuration—to ensure probe penetration depth, thread size, and fitting options match exact mechanical mounting requirements.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013957705910,"sku":"330801-16-10-110-06-02","price":140.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330880-28-25-061-01-021_d90d3cd9-c9ed-41fd-883c-cf8e6bb531e6.jpg?v=1785401489","url":"https:\/\/www.plcsparehub.com\/products\/330801-16-10-110-06-02-bently-nevada-proxpac-proximity-transducer","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}